17 research outputs found

    Quantifying intervertebral disc mechanics: a new definition of the neutral zone

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The neutral zone (NZ) is the range over which a spinal motion segment (SMS) moves with minimal resistance. Clear as this may seem, the various methods to quantify NZ described in the literature depend on rather arbitrary criteria. Here we present a stricter, more objective definition.</p> <p>Methods</p> <p>To mathematically represent load-deflection of a SMS, the asymmetric curve was fitted by a summed sigmoid function. The first derivative of this curve represents the SMS compliance and the region with the highest compliance (minimal stiffness) is the NZ. To determine the boundaries of this region, the inflection points of compliance can be used as unique points. These are defined by the maximum and the minimum in the second derivative of the fitted curve, respectively. The merits of the model were investigated experimentally: eight porcine lumbar SMS's were bent in flexion-extension, before and after seven hours of axial compression.</p> <p>Results</p> <p>The summed sigmoid function provided an excellent fit to the measured data (r<sup>2 </sup>> 0.976). The NZ by the new definition was on average 2.4 (range 0.82-7.4) times the NZ as determined by the more commonly used angulation difference at zero loading. Interestingly, NZ consistently and significantly decreased after seven hours of axial compression when determined by the new definition. On the other hand, NZ increased when defined as angulation difference, probably reflecting the increase of hysteresis. The methods thus address different aspects of the load-deflection curve.</p> <p>Conclusions</p> <p>A strict mathematical definition of the NZ is proposed, based on the compliance of the SMS. This operational definition is objective, conceptually correct, and does not depend on arbitrarily chosen criteria.</p

    In-vitro comparison of LC-DCP- and LCP-constructs in the femur of newborn calves: a pilot study

    Get PDF
    BACKGROUND: To compare the biomechanical in-vitro characteristics of limited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) constructs in an osteotomy gap model of femoral fracture in neonatal calves. Pairs of intact femurs from 10 calves that had died for reasons unrelated to the study were tested. A 7-hole LC-DCP with six 4.5 mm cortical screws was used in one femur and a 7-hole LCP with four 5.0 mm locking and two 4.5 mm cortical screws was used in the corresponding femur. The constructs were tested to failure by cyclic compression at a speed of 2 mm/s within six increasing force levels. RESULTS: The bone-thread interface was stripped in 21 of 80 cortical screws (26.3%) before a pre-set insertion torque of 3 Nm was achieved. Only 3 corresponding intact pairs of constructs could be statistically compared for relative structural stiffness, actuator excursion and width of the osteotomy gap. Relative structural stiffness was significantly greater, actuator excursion and width of the osteotomy gap were significantly smaller in the LCP constructs. While failure occurred by loosening of the screws in the LC-DCP constructs, locking constructs failed by cutting large holes in the soft distal metaphyseal bone. CONCLUSIONS: An insertion torque sufficient to provide adequate stability in femurs of newborn calves could not be achieved reliably with 4.5 mm cortical screws. Another limiting factor for both constructs was the weak cancellous bone of the distal fracture fragment. LCP constructs were significantly more resistant to compression than LC-DCP constructs
    corecore