265 research outputs found
Recommended from our members
Measurements of the Lick Observatory Sodium Laser Guide Star
The Lick Observatory guide star laser has provided a beacon sufficient to close the adaptive optics loop and produce corrected images during runs in 1996 and 1997. This report summarizes measurements of the wavefront quality of the outgoing beam, photoreturn signal from the sodium beacon, and radiance distribution of the guide star on the sky, and follows with an analysis of the impact of the laser on adaptive optics system performance
Recommended from our members
Wide baseline optical interferometry with Laser Guide Stars
Laser guide stars have been used successfully as a reference source for adaptive optics systems. We present a possible method for utilizing laser beacons as sources for interferometric phasing. The technique would extend the sky coverage for wide baseline interferometers and allow interferometric measurement and imaging of dim objects
Recommended from our members
Performance of keck adaptive optics with sodium laser guide star
The Keck telescope adaptive optics system is designed to optimize performance in he 1 to 3 micron region of observation wavelengths (J, H, and K astronomical bands). The system uses a 249 degree of freedom deformable mirror, so that the interactuator spacing is 56 cm as mapped onto the 10 meter aperture. 56 cm is roughly equal to r0 at 1.4 microns, which implies the wavefront fitting error is 0.52 ({lambda}/2{pi})({ital d}/{ital r}{sub 0}){sup 5/6} = 118 nm rms. This is sufficient to produce a system Strehl of 0.74 at 1.4 microns if all other sources of error are negligible, which would be the case with a bright natural guidestar and very high control bandwidth. Other errors associated with the adaptive optics will however contribute to Strehl degradation, namely, servo bandwidth error due to inability to reject all temporal frequencies of the aberrated wavefront, wavefront measurement error due to finite signal-to-noise ratio in the wavefront sensor, and, in the case of a laser guidestar, the so-called cone effect where rays from the guidestar beacon fail to sample some of the upper atmosphere turbulence. Cone effect is mitigated considerably by the use of the very high altitude sodium laser guidestar (90 km altitude), as opposed to Rayleigh beacons at 20 km. However, considering the Keck telescope`s large aperture, this is still the dominating wavefront error contributor in the current adaptive optics system design
Recommended from our members
Lick sodium laser guide star: performance during the 1998 LGS observing campaign
The performance of a sodium laser guide star adaptive optics system depends crucially on the characteristics of the laser guide star in the sodium layer. System performance is quite sensitive to sodium layer spot radiance, that is, return per unit sterradian on the sky, hence we have been working to improve projected beam quality via improvements to the laser and changes to the launched beam format. The laser amplifier was reconfigured to a ''bounce-beam'' geometry, which considerably improves wavefront quality and allows a larger round instead of square launch beam aperture. The smaller beacon makes it easier to block the unwanted Rayleigh light and improves the accuracy of Hartmann sensor wavefront measurements in the A0 system. We present measurements of the beam quality and of the resulting sodium beacon and compare to similar measurements from last year
Recommended from our members
Observing techniques for astronomical laser guide star adaptive optics
We discuss astronomical observing requirements and their implementation using sodium-layer laser guide star adaptive optics. Specific issues requiring implementation include the ability to place the astronomical object at different locations within the field of view; reliable subtraction of Rayleigh-scattered light; efficient focusing; and stable point-spread-function characterization
Stellar Companions to Stars with Planets
A combination of high-resolution and wide-field imaging reveals two binary
stars and one triple star system among the sample of the first 11 stars with
planets detected by radial velocity variations. High resolution speckle or
adaptive optics (AO) data probe subarcsecond scales down to the diffraction
limit of the Keck 10-m or Lick 3-m, and direct images or AO images are
sensitive to a wider field, extending to 10" or 38", depending upon the camera.
One of the binary systems -- HD 114762 -- was not previously known to be a
spatially resolved multiple system; additional data taken with the combination
of Keck adaptive optics and NIRSPEC are used to characterize the new companion.
The second binary system -- Tau Boo -- was a known multiple with two
conflicting orbital solutions; the current data will help constrain the
discrepant estimates of periastron time and separation. Another target -- 16
Cyg B -- was a known common proper motion binary, but the current data resolve
a new third component, close to the wide companion 16 Cyg A. Both the HD 114762
and 16 Cyg B systems harbor planets in eccentric orbits, while the Tau Boo
binary contains an extremely close planet in a tidally-circularized orbit.
Although the sample is currently small, the proportion of binary systems is
comparable to that measured in the field over a similar separation range.
Incorporating the null result from another companion search project lowers the
overall fraction of planets in binary systems, but the detections in our survey
reveal that planets can form in binaries separated by less than 50 AU.Comment: 5 Tables, 16 Figures. ApJ, accepte
Graduates of Lebanese medical schools in the United States: an observational study of international migration of physicians
BACKGROUND: As healthcare systems around the world are facing increasing physician shortages, more physicians are migrating from low to high income countries. As an illustrative case of international migration of physicians, we evaluated the current number and historical trends of Lebanese medical graduates (LMG) in the US, and compared their characteristics to those of US medical graduates (USMG) and other international medical graduates (IMG). METHODS: We evaluated the number of LMG using the 2004 the American Medical Association Physicians' Professional Data (AMA-PPD) and then compared it to the number of graduates of other countries. We evaluated the historical trends using the 1978–2004 historical files of the AMA-PPD. We analyzed the characteristics of all LMG and compared them to a random sample of 1000 USMG and a random sample of 1000 IMG using the 2004 AMA-PPD. RESULTS: In 2004, there were 2,796 LMG in the US, constituting 1.3% of all IMG. Compared to other foreign countries contributing to the US physician workforce, Lebanon ranked 2nd after adjusting for country population size (about 4 million) and 21st overall. About 40% of those who graduated from Lebanese medical schools in the last 25 years are currently active physicians in the US. Since 1978, the number of LMG in the US showed a consistent upward trend at a rate of approximately 71 additional graduates per year. Compared with USMG and IMG, LMG were more likely to work in medical research (OR = 2.31; 95% Confidence Interval (CI) = 1.21; 4.43 and OR = 2.63; 95% CI = 1.34; 5.01, respectively) and to be board certified (OR = 1.43; 95% CI = 1.14; 1.78 and OR = 2.04; 95% CI = 1.65;2.53, respectively) and less likely to be in family practice (OR = 0.14; 95% CI = 0.10; 0.19 and OR = 0.18; 95% CI = 0.12; 0.26, respectively). CONCLUSION: Given the magnitude and historical trends of migration of LMG to the US, further exploration of its causes and impact is warranted. High income countries should consider the consequences of their human resources policies on both low income countries' and their own healthcare systems
The Gaia-ESO Survey: Spectroscopic-asteroseismic analysis of K2 stars in Gaia-ESO
The extensive stellar spectroscopic datasets that are available for studies
in Galactic Archeaology thanks to, for example, the Gaia-ESO Survey, now
benefit from having a significant number of targets that overlap with
asteroseismology projects such as Kepler, K2 and CoRoT. Combining the
measurements from spectroscopy and asteroseismology allows us to attain greater
accuracy with regard to the stellar parameters needed to characterise the
stellar populations of the Milky Way. The aim of this Gaia-ESO Survey special
project is to produce a catalogue of self-consistent stellar parameters by
combining measurements from high-resolution spectroscopy and precision
asteroseismology. We carried out an iterative analysis of 90 K2@Gaia-ESO red giants. The spectroscopic values of Teff were used as input in the seismic analysis to obtain log(g) values. The seismic estimates of log(g) were then used to re-determine the spectroscopic values of Teff and [Fe/H]. Only one iteration was required to obtain parameters that are in good agreement for both methods and thus, to obtain the final stellar parameters. A detailed analysis of outliers was carried out to ensure a robust determination of the parameters. The results were then combined with Gaia DR2 data to compare the seismic log(g) with a parallax-based log(g) and to investigate instances of variations in the velocity and possible binaries within the dataset. This analysis produced a high-quality catalogue of stellar parameters for 90 red giant stars observed by both K2 and Gaia-ESO that were determined through iterations between spectroscopy and asteroseismology. We compared the seismic gravities with those based on Gaia parallaxes to find an offset which is similar to other studies that have used asteroseismology. Our catalogue also includes spectroscopic chemical abundances and radial velocities, as well as indicators for possible binary detections
Recommended from our members
Performance results on the laser portion of the Keck laser guide star system
The Laser Guide Star (LGS) system for the Keck II, 10 m telescope consists of two separate but interconnected systems, the laser and the adaptive optics bench. The laser portion of the LGSl is a set of five frequency doubled YAG lasers pumping a master oscillator-power amplifier dye chain to produce up to 30 W of 589 p at 26 kHz of tuned light. Presently the laser system has been set up at the Keck facility in Waimea, HI and is undergoing test and evaluation. When it will be set up on the Keck II telescope, the pump lasers, dye master oscillator and associated control equipment will be located on the dome floor and the dye laser amplifiers, beam control system and diagnostics will be mounted directly on the telescope as shown in Fig. 1, Extensive use of fiber optics for both transmission of the oscillator pulse and the pump laser light has been used
- …