26 research outputs found

    Complement C3 serum levels in anorexia nervosa: a potential biomarker for the severity of disease?

    Get PDF
    BackgroundAnorexia nervosa carries the highest mortality rate of any psychiatric disorder. Even the most critically ill anorexic patients may present with normal 'standard' laboratory values, underscoring the need for a new sensitive biomarker. The complement cascade, a major component of innate immunity, represents a driving force in the pathophysiology of multiple inflammatory disorders. The role of complement in anorexia nervosa remains poorly understood. The present study was designed to evaluate the role of complement C3 levels, the extent of complement activation and of complement hemolytic activity in serum, as potential new biomarkers for the severity of anorexia nervosa.Patients and methodsThis was a prospective cohort study on 14 patients with severe anorexia nervosa, as defined by a body mass index (BMI) <14 kg/m2. Serum samples were obtained in a biweekly manner until hospital discharge. A total of 17 healthy subjects with normal BMI values served as controls. The serum levels of complement C3, C3a, C5a, sC5b-9, and of the 50% hemolytic complement activity (CH50) were quantified and correlated with the BMIs of patients and control subjects.ResultsSerum C3 levels were significantly lower in patients with anorexia nervosa than in controls (median 3.7 (interquartile range (IQR) 2.5-4.9) vs 11.4 (IQR 8.9-13.7, P <0.001). In contrast, complement activation fragments and CH50 levels were not significantly different between the two groups. There was a strong correlation between index C3 levels and BMI (Spearman correlation coefficient = 0.71, P <0.001).ConclusionsComplement C3 serum levels may represent a sensitive new biomarker for monitoring the severity of disease in anorexia nervosa. The finding from this preliminary pilot study will require further investigation in future prospective large-scale multicenter trials

    Worse Postoperative Outcomes and Higher Reoperation in Smokers Compared to Nonsmokers for Arthroscopic Rotator Cuff Repair

    Get PDF
    Introduction: Smoking impairs healing potential and is a significant risk factor for complications following orthopaedic surgeries. The purpose of this study was to determine if a cohort of former or current smokers at time of surgery met the minimally clinical important difference (MCID) for Patient-Reported Outcomes Measurement Information System Upper Extremity (PROMIS-UE), Depression (PROMIS-D), and Pain Interference (PROMIS-PI) scores in comparison to nonsmokers. Methods: A retrospective review of patients who underwent rotator cuff repair was performed. Patients who completed preoperative and 6-month postoperative PROMIS scores were included. The MCID was calculated using a distribution technique with a threshold of 0.5 standard deviations above the mean. A cohort of nonsmokers was compared to current/former smokers in terms of clinical outcomes and PROMIS scores. Results: A total of 182 patients, 80 current/former smokers and 102 nonsmokers, were included. Smokers had significantly more massive-sized tears and more reoperations (16.3% vs 5.9%,P=0.02). No differences were found in change in PROMIS scores, proportion meeting MCID for PROMIS scores, and retear rate. In the sub-analysis, 74 current/former smokers were matched to 74 nonsmokers. Smokers had lower change in PROMIS-UE (8.6±9.8 vs 12.3±10.0,P=0.007) and PROMIS-PI (-9.1±8.5 vs -12.8±10.1,P=0.03) postoperatively. Fewer met MCID for PROMIS UE postoperatively (60.3% vs 82.4%,P=0.003) and more had reoperations (16.2% vs 4.1%,P=0.02). Conclusion: Smokers or former smokers demonstrated smaller improvements in function, pain scores, and were less likely to meet MCID for PROMIS-UE when compared to nonsmokers after arthroscopic rotator cuff repair. Smokers were more likely to undergo reoperations within 6 months

    Long-term outcome with the automatic implantable cardioverter-defibrillator

    Get PDF
    AbstractThe automatic implantable cardioverter-defibrillator was implanted in 270 patients because of life-threatening arrhythmias over a 7 year period. There was a history of sustained ventricular tachycardia or fibrillation, or both, in 96% of these patients, 80% had one or more prior cardiac arrests and 78% had coronary artery disease as their underlying diagnosis. The average ejection fraction was 34%, and 96% of these patients had had an average of 3.4 antiarrhythmic drug failures per patient before defibrillator implantation. There were four perioperative deaths and eight patients had generator infection or generator erosion, or both, during the perioperative period or during long-term follow-up. Concomitant antiarrhythmic drug therapy was given to 69% of patients.Shocks from the device were given to 58% of patients, and 20% received “problematic” shocks. The device was removed from 16 patients during long-term follow-up for a variety of reasons. There were 7 sudden cardiac deaths and 30 nonsudden cardiac deaths, 18 of which were secondary to congestive heart failure. The actuarial incidence of sudden death, total cardiac death and total mortality from all causes was 1%, 7% and 8%, respectively, at 1 year, and 4%, 24% and 26% at 5 years.The automatic implantable cardioverter-defibrillator nearly eliminates sudden death over a long-term follow-up period in a high risk group of patients. It has an acceptable rate of complications or problems, or both, and most late deaths in these patients are nonsudden and of cardiovascular origin

    Reduced Career Longevity but Return to Baseline Performance After Arthroscopic Shoulder Labral Repair in National Hockey League Players

    Get PDF
    PURPOSE: To investigate the impact of arthroscopic shoulder labral repair without shoulder instability on career longevity, game use, and performance in National Hockey League (NHL) athletes. METHODS: A retrospective review of all NHL players who underwent arthroscopic shoulder labral repair from 2004 to 2020 was performed. A 2:1 matched control group was used for comparison. Controls were matched by age, body mass index, position, and experience prior to the index year. Demographic characteristics, game use, and performance metrics were collected for all athletes. Statistical analysis examined game use and performance both at 1-year and 3-year follow-up compared with one season before injury. RESULTS: Twenty-nine players who underwent arthroscopic shoulder labral surgery returned to play (100%) and were matched with 55 control players. The operative cohort experienced shorter careers compared with controls (4.4 ± 3.1 vs 6.0 ± 3.6 seasons, P < .05). After one season, injured players experienced significant reductions in goals per 60 (0.6 ± 0.4 vs 0.8 ± 0.5, P = .013), points per 60 (1.5 ± 0.9 vs 2.0 ± 0.9, P = .001), and shooting percentage, (8.5 ± 5.8 vs 10.5 ± 5.2, P = .02) compared with the year prior. The reduction in goals (0.6 ± 0.4 vs 0.8 ± 0.5, P = .01) and shooting % (8.5 ± 4.7 vs 10.5 ± 5.2, P = .04) persisted at 3 years. Compared with controls, the surgical group experienced significant reductions at one season postindex in percentage of goals, assists, points per 60, and shooting percentage. Only the reduction in goals per 60 persisted at 3 seasons postindex. CONCLUSIONS: Following return to play after arthroscopic shoulder labral repair, NHL players demonstrated reduced career longevity compared with healthy controls. Players exhibited significant reductions in game use and performance at one season after injury but returned closer to baseline after 3 seasons. LEVEL OF EVIDENCE: Level III; retrospective case control

    5-Year Survivorship and Outcomes of Robotic-Arm-Assisted Medial Unicompartmental Knee Arthroplasty

    Get PDF
    Purpose: While unicompartmental knee arthroplasty (UKA) has demonstrated benefits over total knee arthroplasty (TKA) in selected populations, component placement continues to be challenging with conventional surgical instruments, resulting in higher early failure rates. Robotic-arm-assisted UKA (RA-UKA) has shown to be successful in component positioning through preop planning and intraop adjustability. The purpose of this study is to assess the 5-year clinical outcomes of medial RA-UKA. Methods: This study was a retrospective review of a single-center prospectively maintained cohort of 133 patients (146 knees) indicated for medial UKA from 2009 to 2013. Perioperative data and 2- and 5-year Knee injury Osteoarthritis Outcome Score (KOOS), Western Ontario and McMaster Universities Osteoarthritis Score (WOMAC), and Forgotten Joint Score (FJS) outcome measures were collected. Five-year follow-up was recorded in 119 patients (131 knees). Results: Mean follow-up was 5.1 ± 0.2 years. Mean age and BMI were 68.0 ± 8.1 years and 29.3 ± 4.7 kg/m(2), respectively. At 2-year follow-up, mean KOOS, WOMAC, and FJS were 71.5 ± 15.3, 14.3 ± 7.9, and 79.1 ± 25.8, respectively. At 5-year follow-up, mean KOOS, WOMAC, and FJS were 71.6 ± 15.2, 14.2 ± 7.9, and 80.9 ± 25.1, respectively. Mean change in KOOS and WOMAC was 34.6 ± 21.4 and 11.0 ± 13.6, respectively (p \u3c 0.001 and p \u3c 0.001). For patient satisfaction at last follow-up, 89% of patients were very satisfied/satisfied and 5% were dissatisfied. For patient activity expectations at last follow-up, 85% met activity expectations, 52% were more active than before, 25% have the same level of activity, 23% were less active than before, and 89% were walking without support. All patients returned to driving after surgery at a mean 15.2 ± 9.4 days. Survivorship was 95% (95% CI 0.91-0.98) at 5 years. One knee (1%) had a patellofemoral revision, two knees (1.3%) were revised to different partial knee replacements, and five knees (3.4%) were converted to TKA. Conclusion: Overall, medial RA-UKA demonstrated improved patient-recorded outcomes, high patient satisfaction, met expectations, and excellent functional recovery. Midterm survivorship was excellent. Longitudinal follow-up is needed to evaluate long-term outcomes of robotic-arm-assisted UKA procedures

    Robotic-arm assisted lateral unicompartmental knee arthroplasty: 5-Year outcomes & survivorship

    Get PDF
    INTRODUCTION: Robotic-arm assisted unicompartmental knee arthroplasty (RA-UKA) has demonstrated accurate component positioning and excellent outcomes for medial components. However, there is a paucity of literature on lateral compartment RA-UKA. The purpose of our study was to assess the midterm clinical outcomes and survivorship of lateral RA-UKA. METHODS: This study was a retrospective review of a single-center prospectively maintained cohort of 33 patients (36 knees) indicated for lateral UKA. Perioperative, and postoperative two- and five-year Knee injury Osteoarthritis Outcome Score (KOOS), Western Ontario and McMaster Universities Osteoarthritis Score (WOMAC), and Forgotten Joint Score (FJS) patient reported outcome measures were collected. Five-year follow-up was recorded in 29 patients (32 knees). RESULTS: Mean follow up was 5.1 ± 0.1 years. Mean age and BMI was 70.9 ± 7.2 years and 29.0 ± 4.2 kg/m2, respectively. At discharge, mean distance walked was 273.4 ± 70.4 feet, and mean pain score was 2.0 ± 2.5. At 2-year follow up, mean KOOS, WOMAC, and FJS were 75.1 ± 13.5, 15.0 ± 7.2, and 81.0 ± 23.3, respectively. At 5-year follow up, mean KOOS, WOMAC, and FJS were 75.3 ± 14.6, 14.9 ± 5.0, and 75.8 ± 27.4, respectively. Mean change in KOOS and WOMAC were 35.6 ± 27.1 and 11.7 ± 13.4 (p\u3c .001 and p\u3c .001). 94% of patients were very satisfied/satisfied, 3% neutral, and 3% dissatisfied. 91% met activity expectations, and 59% were more active than before. Survivorship was 100% at 5 years. DISCUSSION: In this study, lateral RA-UKA demonstrated significantly improved clinical outcomes, high patient satisfaction, met expectations, and excellent functional recovery at midterm follow up. Comparative studies are needed to determine differences between robotic-assisted and conventional lateral UKA, as well as TKA

    Transvenous catheter ablation of extranodal accessory pathways

    Get PDF
    AbstractTwelve patients with an accessory pathway and recurrent symptomatic reciprocating tachycardia or atrial fibrillation, or both, underwent attempted transvenous catheter ablation of the accessory pathway. In one patient with a small right coronary artery, the pathway was along the right free wall. In 11 patients, the pathway was located at or within 15 mm of the coronary sinus os. For these patients, a quadripolar electrode catheter was placed in the coronary sinus and positioned, if possible, so that the proximal pair of electrodes straddled the pathway. For those patients with a pathway > 5 mm within the coronary sinus, the most proximal electrode was placed at the os. This proximal pair of electrodes was connected to the cathodal output of a defibrillator with an anterior chest wall patch serving as the current sink. Two shocks were then delivered for a cumulative energy of 500 to 600 J (stored energy).Among the eight patients with a pathway at or within 5 mm of the coronary sinus os, conduction over the pathway was abolished in five and modified in one. Among the four patients with a pathway farther from the os (10 to 15 mm) and along the right free wall, pathway conduction was modified only in two. Rupture of the coronary sinus did not occur in any patient. There were no serious complications. Minor damage surrounding the area of ablation was seen at the time of surgical division of the accessory pathway in two of five patients with unsuccessful ablation who subsequently underwent surgery.Transvenous catheter ablation of accessory pathways appears to be a safe and reasonably effective alternative to surgery for those patients with a pathway at or near the coronary sinus os, but not for those with a pathway farther from the septum. Although subsequent intraoperative mapping was more difficult because of the loss of large, discrete atrial electrograms, surgical division was successful in all five patients after unsuccessful catheter ablation

    Upper-Extremity Injuries Have the Poorest Return to Play and Most Time Lost in Professional Baseball: A Systematic Review of Injuries in Major League Baseball

    No full text
    PURPOSE: To summarize the incidence of injuries occurring in professional baseball and compare player outcomes reported in the literature. METHODS: We conducted a systematic review using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines across 3 databases (PubMed, MEDLINE, Embase). Inclusion criteria were studies of injury incidences and/or injury outcomes on active Major League Baseball (MLB) athletes and studies published in the English language. Exclusion criteria were non-MLB players, case series and case report studies with a cohort of ≤3 players, and/or review articles. RESULTS: A total of 477 articles were identified from the initial search of 3 databases, with 105 studies meeting inclusion criteria. Among these articles, the most common injuries studied were elbow (38%), shoulder (14%), hip/groin (11%), hand/wrist (7%), head/face (7%), knee (7%), spine (5%), and foot/ankle (3%). Injuries with the greatest incidence included hand/wrist (150.3 per year), hamstring (7.8-73.5 per year), ulnar collateral ligament (UCL) tears (0.23-26.8 per year), gastrocnemius strains (24.2 per year), and concussions (3.6-20.5 per year). Lowest rates of return to play were seen following shoulder labral tears (40%-72.5%), rotator cuff tears (33.3%-87%), and UCL tears (51%-87.9%). The injuries leading to most time away from sport included elbow UCL tears (average 90.3 days treated nonoperatively to 622.8 days following revision reconstruction), shoulder labral tears (average 315-492 days), and anterior cruciate ligament (ACL) tears (average 156.2-417.5 days). Following ACL tears, rotator cuff tears, shoulder labral tears, and hip femoroacetabular impingement requiring arthroscopy, athletes had a significantly lower workloads compared with before injury upon return to play. CONCLUSIONS: Most published investigations focus on elbow injuries of the UCL, with variable return to play and mixed performance following surgery. UCL tears, shoulder labral tears, and ACL tears result in the most missed time. Upper-extremity injury such as shoulder labral tears, rotator cuff tears, and UCL tears had the poorest return to play rates. Workload was most affected following ACL reconstruction, rotator cuff repair, shoulder labral repair, and hip arthroscopy for femoroacetabular impingement. LEVEL OF EVIDENCE: IV, systematic review of level II-IV studies

    Premeasured chordal loops for mitral valve repair.

    No full text
    Premeasured expanded polytetrafluoroethylene chordal loops with integrated sutures for attachment to the papillary muscle and leaflet edges facilitate correction of mitral valve prolapse. Configured as a group of 3 loops (length range 12 to 24 mm), the loops are attached to a pledget that is passed through the papillary muscle and tied. Each of the loops has 2 sutures with attached needles; these needles are passed through the free edge of the leaflet and then the sutures are tied to each other, securing the chordal loop to the leaflet
    corecore