657 research outputs found

    FLAT MANIFOLDS WITH HOLONOMY GROUP ℤ^k_2 OF DIAGONAL TYPE

    Full text link

    The FPGA-based Continious FFT Tune Measurement System for the LHC and its test at the CERN SPS

    Get PDF
    A base band tune (BBQ) measurement system has been developed at CERN. This system is based on a high-sensitivity direct-diode detection technique followed by a high resolution FFT algorithm implemented in an FPGA. The system allows acquisition of continuous real-time spectra with 32-bit resolution, while a digital frequency synthesiser (DFS) can provide an acquisition synchronised chirp excitation. All the implemented algorithms support dynamic reconfiguration of processing and excitation parameters. Results from both laboratory measurements and tests performed with beam at the CERN SPS are presented

    Kinetics and Products of Air Plasma Induced Oxidation in Water of Imidacloprid and Thiamethoxam Treated Individually and in Mixture

    Get PDF
    Imidacloprid (I) and thiamethoxam (T) are widely used neonicotinoid insecticides with high persistence in the environment and thus included in the watch list of substances for European Union-wide monitoring reported in the Decision 2015/495/EU. In this work aqueous solutions of I, T and I + T were subjected to advanced oxidation by air plasma produced by negative DC corona discharges above the liquid surface. The oxidative degradation of each pollutant was investigated by monitoring the rate and the products of its decay when treated alone and in the presence of variable amounts of the other compound. The results show that both I and T are readily degraded and that mineralization can be achieved in this process, as proven by the measurement of the residual organic carbon and by the quantitative conversion of chlorine and sulfur into inorganic chloride and sulfate, respectively. The major organic intermediates formed during the complex stepwise oxidation of I and T were identified and monitored by HPLC\u2013MS/MS analysis. The results of kinetic studies show that both for I and T the reaction rate depends inversely on the insecticide initial concentration, that I and T have similar reactivities and that they do not interfere reciprocally in any specific way when treated in mixture at a total concentration of ca 1 7 10 124 M. Based on literature data and on previous results with the same reactor, it is reasonable to propose that the oxidation of I and T is initiated by the reaction with OH radicals

    Locating, and Utilising \u3cem\u3eFestuca Pratensis\u3c/em\u3e Genes for Winter Hardiness for the Future Development of More Persistent High Quality \u3cem\u3eLolium\u3c/em\u3e Cultivars

    Get PDF
    Genes for freezing-tolerance and winter hardiness were located in Festuca pratensis by QTL analysis and introgression-mapping. QTL for freezing-tolerance on F. pratensis chromosome 4 were orthologous to rice chromosome 3, and Triticeae chromosome 5. Increased energy dissipation during the autumn through a lower maximum quantum yield of photosystem II (PSII) was correlated with improved winter survival. Freezing tolerance in Lolium was achieved by the transfer and subsequent expression of F. pratensis genes from chromosome 4 that govern the expression of a non-photochemical (NPQ) mechanism for the dissipation of excess light energy under low temperature

    On the Continuous Measurement of the LHC Beta-Function - Prototype Studies at the SPS

    Get PDF
    Until now, the continuous monitoring of the LHC lattice has been considered impractical due to tight constraints on the maximum allowed beam excitations and acquisition time usually required for betatron function measurements. As a further exploitation of the Base-Band-Tune (BBQ) detection principle, already widely used for tune diagnostics, a real-time beta-beat measurement prototype has been successfully tested at the CERN SPS and is based on the continuous measurement of the cell-to-cell betatron phase advance. Tests show that the phase resolution is better than a degree corresponding to a peak-to-peak beta-beat resolution of better than a percent. Due to the system’s high sensitivity, it required only micrometre-range excitation, making it compatible with nominal LHC operation. This contribution discusses results, measurement systematics and exploitation possibilities that may be used to improve the nominal LHC performance

    Simultaneous tune and coupling feedback in the Relativistic Heavy Ion Collider, and possible implications for the Large Hadron Collider commissioning

    Get PDF
    Simultaneous tune and coupling feedback were successfully implemented during RHIC run 6. In this paper we describe the measurement and control hardware and software used to accomplish this, present some of the results, discuss areas that require further investigation, and finally offer a few comments on possible implications of these results for LHC commissioning

    Beam size measurements based on movable quadrupolar pick-ups

    Get PDF
    Quadrupolar pick-ups (PU) have been widely studied as candidates for non-intercepting beam size and emittance measurements. However, their application has been proven to be limited. Two fundamental factors make quadrupolar measurements exceptionally challenging: first, the low quadrupolar sensitivity of PUs and second, the parasitic position signal incorporated into the measured quadrupolar measurement. In this paper, an alignment technique, based on movable PUs, is proposed to efficiently cancel the parasitic position signal. Tests have been performed using PUs embedded in collimators in the Large Hadron Collider. Beam measurements demonstrate promising results.peer-reviewe
    corecore