2,182 research outputs found

    Scan to BIM for 3D reconstruction of the papal basilica of saint Francis in Assisi In Italy

    Get PDF
    The historical building heritage, present in the most of Italian cities centres, is, as part of the construction sector, a working potential, but unfortunately it requires planning of more complex and problematic interventions. However, policies to support on the existing interventions, together with a growing sensitivity for the recovery of assets, determine the need to implement specific studies and to analyse the specific problems of each site. The purpose of this paper is to illustrate the methodology and the results obtained from integrated laser scanning activity in order to have precious architectural information useful not only from the cultural heritage point of view but also to construct more operative and powerful tools, such as BIM (Building Information Modelling) aimed to the management of this cultural heritage. The Papal Basilica and the Sacred Convent of Saint Francis in Assisi in Italy are, in fact, characterized by unique and complex peculiarities, which require a detailed knowledge of the sites themselves to ensure visitor’s security and safety. For such a project, we have to take in account all the people and personnel normally present in the site, visitors with disabilities and finally the needs for cultural heritage preservation and protection. This aim can be reached using integrated systems and new technologies, such as Internet of Everything (IoE), capable of connecting people, things (smart sensors, devices and actuators; mobile terminals; wearable devices; etc.), data/information/knowledge and processes to reach the desired goals. The IoE system must implement and support an Integrated Multidisciplinary Model for Security and Safety Management (IMMSSM) for the specific context, using a multidisciplinary approach

    Mediterranean spreading of the bicolor purse oyster, Isognomon bicolor, and the chicken trigger, Malleus sp., vs. the Lessepsian prejudice

    Get PDF
    The introduction rate of alien species in the Mediterranean Sea is rapidly growing, and their taxonomical identification is increasingly challenging. This uncertain identification often leads to an incorrect estimation of the number of alien species, their route of introduction, and their potential negative effects. This is particularly true for some bivalves, which are characterized by high variation in their shells, resulting in uncertain morphological identification. This is the case for two alien bivalves, i.e., an Isognomonidae and a Malleidae species, both characterized by confused historical colonization records in the Mediterranean Sea, misidentifications, and controversial and changing nomenclatures that have insofar negatively affected our knowledge on their geographical distributions. In this respect, molecular approaches provide a strategy that is especially useful when traditional taxonomy fails, and DNA barcoding is a powerful and well-known tool to obtain reliable identifications through efficient molecular markers. In this work, we used the 16S rRNA marker to assess the preliminary identification of Isognomon sp. and Malleus sp. specimens from different localities in the Southern Mediterranean Sea. Bayesian inference (BI) and maximum likelihood (ML) methods were applied to test the monophyly of the phylogenetic linages and to clarify their taxonomic positions, allowing a complete overview of the colonization and spreading of these two alien bivalves in the Mediterranean Sea. In particular, the Isognomon sp. specimens were identified as the Atlantic I. bicolor, highlighting that previously suggested invasive migration patterns, (i.e., the Lessepsian migration), must be reconsidered with stronger critical attention in light of currently occurring global changes

    u-RANIA: a neutron detector based on \mu -RWELL technology

    Full text link
    In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL (μ\mu -RWELL) technology. The μ\mu -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B4_4C on the copper surface of the cathode allows the thermal neutrons detection through the release of 7^7Li and α\alpha particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the 3^3He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.Comment: Prepared for the INSTR20 Conference Proceeding for JINS

    Oneiric stress and safety and security at work: the discovery of a new universal symbol

    Get PDF
    Cox and Griffiths define as psychosocial risks at work “those aspects of the planning, organization and management of work, which, along with their environmental and social contexts, may affect mental and physical health of the employees, directly or indirectly producing stress”. Therefore, a more effective approach to occupational safety and security should include integrated risk management through the identification of any work stress related problem. The purpose of this paper is to analyze the possible correlation of risk at work with the modification of sleep, and inside it, the specific function of dream activity

    A model to explain angular distributions of J/ψJ/\psi and ψ(2S)\psi(2S) decays into ΛΛ\Lambda\overline{\Lambda} and Σ0Σ0\Sigma^0\overline{\Sigma}^0

    Full text link
    BESIII data show a particular angular distribution for the decay of the J/ψJ/\psi and ψ(2S)\psi(2S) mesons into the hyperons ΛΛ\Lambda\overline{\Lambda} and Σ0Σ0\Sigma^0\overline{\Sigma}^0. More in details the angular distribution of the decay ψ(2S)Σ0Σ0\psi(2S) \to \Sigma^0\overline{\Sigma}^0 exhibits an opposite trend with respect to that of the other three channels: J/ψΛΛJ/\psi \to \Lambda\overline{\Lambda}, J/ψΣ0Σ0J/\psi \to \Sigma^0\overline{\Sigma}^0 and ψ(2S)ΛΛ\psi(2S) \to \Lambda\overline{\Lambda}. We define a model to explain the origin of this phenomenon.Comment: 6 pages, 7 figures, to be published in Chinese Physics

    A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP

    Full text link
    The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since the beginning of its operation, BESIII has collected the world largest sample of J/{\psi} and {\psi}(2s). Due to the increase of the luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC decreases its efficiency in the first layers up to 35% with respect to the value in 2014. Since BESIII has to take data up to 2022 with the chance to continue up to 2027, the Italian collaboration proposed to replace the inner part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM). The CGEM-IT project will deploy several new features and innovation with respect the other current GEM based detector: the {\mu}TPC and analog readout, with time and charge measurements will allow to reach the 130 {\mu}m spatial resolution in 1 T magnetic field requested by the BESIII collaboration. In this proceeding, an update of the status of the project will be presented, with a particular focus on the results with planar and cylindrical prototypes with test beams data. These results are beyond the state of the art for GEM technology in magnetic field

    The Straw Tube Trackers of the PANDA Experiment

    Full text link
    The PANDA experiment will be built at the FAIR facility at Darmstadt (Germany) to perform accurate tests of the strong interaction through bar pp and bar pA annihilation's studies. To track charged particles, two systems consisting of a set of planar, closed-packed, self-supporting straw tube layers are under construction. The PANDA straw tubes will have also unique characteristics in term of material budget and performance. They consist of very thin mylar-aluminized cathodes which are made self-supporting by means of the operation gas-mixture over-pressure. This solution allows to reduce at maximum the weight of the mechanical support frame and hence the detector material budget. The PANDA straw tube central tracker will not only reconstruct charged particle trajectories, but also will help in low momentum (< 1 GeV) particle identification via dE/dx measurements. This is a quite new approach that PANDA tracking group has first tested with detailed Monte Carlo simulations, and then with experimental tests of detector prototypes. This paper addresses the design issues of the PANDA straw tube trackers and the performance obtained in prototype tests.Comment: 7 pages,16 figure

    Treatment decision-making of secondary prevention after venous thromboembolism. data from the real-life START2-POST-VTE register

    Get PDF
    Patients with venous thromboembolism (VTE) should receive a decision on the duration of anticoagulant treatment (AT) that is often not easy to make. Sixteen Italian clinical centers included patients with recent VTE in the START2-POST-VTE register and reported the decisions taken on duration of AT in each patient and the reasons for them. At the moment of this report, 472 (66.9%) of the 705 patients included in the registry were told to stop AT in 59.3% and to extend it in 40.7% of patients. Anticoagulant treatment lasted ≥3 months in &gt;90% of patients and was extended in patients with proximal deep vein thrombosis because considered at high risk of recurrence or had thrombophilic abnormalities. d-dimer testing, assessment of residual thrombus, and patient preference were also indicated among the criteria influencing the decision. In conclusion, Italian doctors stuck to the minimum 3 months AT after VTE, while the secondary or unprovoked nature of the event was not seen as the prevalent factor influencing AT duration which instead was the result of a complex and multifactorial evaluation of each patient
    corecore