522 research outputs found

    Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study

    Get PDF
    Since the introduction of nickel-titanium alloy to endodontics, there have been many changes in instrument design, but no significant improvements in the raw material properties, or enhancements in the manufacturing process. Recently, a new method to produce nickel-titanium rotary (NTR) instruments has been developed, in an attempt to obtain instruments that are more flexible and resistant to fatigue. NTR instruments produced using the process of twisting (TF, SybronEndo, Orange, CA) were compared to NTR instruments from different manufacturers produced by a traditional grinding process. The aim of the study was to investigate whether cyclic fatigue resistance is increased for TF NTR files. Tests were performed with a cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (P< .05). In the mean number of cycles to failurewhen compared to the other tested 06-25 NTR. Hence, it can be concluded that size 06-25 TF NTR instruments were found to be significantly more resistant to fatigue than those produced with the traditional grinding process

    Fatigue resistance of new and used nickel-titanium rotary instruments: a comparative study

    Get PDF
    Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones

    In vivo evaluation of operative torque generated by two Nickel-Titanium rotary instruments during root canal preparation

    Get PDF
    Objectives This in vivo study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars. Materials and Methods Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (n = 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds). Statistical Analysis Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann-Whiney U test with a significance level set at 5%. Results No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (p &gt; 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2-9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35-21.1) (p &lt; 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18-0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05-0.17) (p &lt; 0.05). Conclusions Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals

    Role of the flat-designed surface in improving the cyclic fatigue resistance of endodontic NiTi rotary instruments

    Get PDF
    The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel-titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon-Mann-Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p &lt; 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments

    A survey on perceived COVID-19 risk in dentistry and the possible use of rapid tests

    Get PDF
    Aim: The present study was conducted to assess the perceived risk of COVID-19 transmission in dental professionals (DPs), that include dentists and dental auxiliary staffs, and whether rapid tests should be a recommended tool to constrain the transmission of the COVID-19, and who should be bearing their cost (governments, dentists, or patients) through an online survey. Materials and methods: A sample size of n = 700 was recruited in the study. The study included DPs from all over the world. A randomized selection of samples was done through dental groups present on social networks. An online survey was conducted in April 2020, using the Google Form software to provide questions and collect and elaborate answers. Data were analyzed using the statistical software STATA and presented in terms of percentages. Results: About 78% of the study participants perceived a very high risk of COVID-19 contamination in dental settings. Nearly 80% of the study participants were willing to be subjected to rapid tests and the same could be performed on patients visiting their dental clinics, which could prevent the spread of the disease. About 55% of the participants had reported that additional costs for the rapid tests should be borne by the governments. Conclusion: The results of the present survey report that DPs do not feel safe and perceive a high risk of COVID-19 contagion and prevention of the disease could be done by performing rapid tests on dentists, dental staff, and patients visiting the dental clinics irrespective of age and gender of the participants. Significance: Since all the dentists and allied staff have perceived increased risk for COVID-19 transmission, it is important that preventive measures are implemented through rapid test kits at the earliest

    The influence of a new clinical motion for endodontic instruments on the incidence of postoperative pain

    Get PDF
    Previous studies showed that motor motions play an important role in determining apical extrusion of debris. Therefore a new clinical motion (MIMERACI) has been proposed. The basic idea is to progress slowly (1mm advancement), and after each 1mm, to remove the instrument from the canal, clean flutes and irrigate. The aim of the study was to prove whether the clinical use of MIMERACI technique would influence or not postoperative pain.MATERIALS AND METHODS: 100 teeth requesting endodontic treatment were selected for the study and divided into two similar groups based on anatomy, pre-operative symptoms and vitality, presence or absence of periapical lesion. All teeth were shaped, cleaned and obturated by the same operator, using the same NiTi instruments. The only difference between the two groups was the instrumentation technique: tradional (group A) vs MIMERACI (group B). Assessment of postoperative pain was performed 3 days after treatment. Presence, absence and degree of pain were recorded with a visual analogue scale (VAS), validated in previous studies. Collected data statistically analyzed using one-way ANOVA post hoc Tukey test. RESULTS: For VAS pain scores MIMERACI technique showed significantly better results than group A (p=0,031). Overall, both incidence and intensity of symptoms were significantly lower. Flare ups occurred in 3 patients, but none treated with the MIMERACI Technique. CONCLUSIONS: Since extruded debris can elicit more postoperative pain, results obtained by using MIMERACI technique are probably due to many factors: better mechanical removal and less production of debris and more efficient irrigation during instrumentation

    Influence of the shape of artificial canals on the fatigue resistance of NiTi rotary instruments

    Get PDF
    To investigate the influence of the trajectory of NiTi rotary instruments on the outcome of cyclic fatigue tests. Ten ProFile and Mtwo instruments tip size 20, taper 0.06 and tip size 25, taper 0.06 were tested in two simulated root canals with an angle of curvature of 60 degrees and radius of curvature of 5 mm but with different shape. Geometrical analysis of the angle and radius of the curvature that each instrument followed inside the two different artificial canals was performed on digital images. The instruments were then rotated until fracture at a constant speed of 300 rpm to calculate the number of cycles to failure (NCF) and the length of the fractured fragment. Mean values were calculated and analysed using two different multivariate linear regression models and an independent sample t-test. The shape of the artificial root canal used in cyclic fatigue studies influenced the trajectory of the instrument. This difference is reflected by the NCF measured for the same instrument in the different artificial root canals and by the impact of the type of canal on both the NCF (St.beta = 0.514) and fragment length (St.beta = -0.920). Small variations in the geometrical parameters of the curvature of an instrument subjected to flexural fatigue could have a significant influence on the results of fatigue tests
    • …
    corecore