6 research outputs found

    Risk scores in cardiac resynchronization therapy - a review of the literature

    No full text
    Cardiac resynchronization therapy (CRT) for selected heart failure (HF) patients improves symptoms and reduces morbidity and mortality; however, the prognosis of HF is still poor. There is an emerging need for tools that might help in optimal patient selection and provide prognostic information for patients and their families. Several risk scores have been created in recent years; although, no literature review is available that would list the possible scores for the clinicians. We identified forty-eight risk scores in CRT and provided the calculation methods and formulas in a ready-to-use format. The reviewed score systems can predict the prognosis of CRT patients; some of them have even provided an online calculation tool. Significant heterogeneity is present between the various risk scores in terms of the variables incorporated and some variables are not yet used in daily clinical practice. The lack of cross-validation of the risk scores limits their routine use and objective selection. As the number of prognostic markers of CRT is overwhelming, further studies might be required to analyze and cross-validate the data. </p

    Picking the locked door: experiences and techniques in transseptal puncture post-atrial septal defect occlusion

    No full text
    The management of atrial septal defects (ASDs) has been revolutionized by the advent of percutaneous transvenous occlusion devices. This case series describes techniques required to perform a transeptal puncture safely and effectively in patients postimplantation of an atrial septal defect occluder to facilitate catheter ablation of atrial arrhythmias.</p

    Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures

    No full text
    Objective: Pulmonary vein isolation (PVI) is the cornerstone of the interventional treatment of atrial fibrillation (AF). Traditionally, during these procedures the catheters are guided by fluoroscopy, which poses a risk to the patient and staff by ionizing radiation. Our aim was to describe our experience in the implementation of an intracardiac echocardiography (ICE) guided zero fluoroscopic (ZF) ablation approach to our routine clinical practice. Methods: We developed a simplified ICE guided technique to perform ablation procedures for AF, with the aid of a 3D electroanatomical mapping system. The workflow was implemented in two phases: (1) the Introductory phase, where the first 16 ZF PVIs were compared with 16 cases performed with fluoroscopy and (2) the Extension phase, where 71 consecutive patients (including repeat procedures) with ZF approach were included. Standard PVI (and redoPVI) procedures were performed, data on feasibility of the ZF approach, complications, acute and 1-year success rates were collected. Results: In the Introductory phase, 94% of the procedures could be performed with complete ZF with a median procedure time of 77.5 (73.5-83) minutes. In one case fluoroscopy was used to guide the ICE catheter to the atrium. There was no difference in the complication, acute and 1-year success rates, compared with fluoroscopy guided procedures. In the Extension phase, 97% of the procedures could be completed with complete ZF. In one case fluoroscopy was used to guide the transseptal puncture and in another to position the ICE catheter. Acute success of PVI was achieved in all cases, 64.4% patients were arrhythmia free at 1-year. Acute major complications were observed in 4 cases, all of these occurred in the redo PVI group and consisted of 2 tamponades, 1 transient ischemic attack and 1 pseudoaneurysm at the puncture site. The procedures were carried out by all members of the electrophysiology unit in the Extension phase, including less experienced operators and electrophysiology fellows (3 physicians) under the supervision of the senior electrophysiologist. Consequently, procedure times became longer [90 (75-105) vs 77.5 (73.5-85) min, p = 0.014]. Conclusions: According to our results, a ZF workflow of AF ablations can be successfully implemented into the routine practice of an electrophysiology laboratory, without compromising safety and effectivity.</p

    The impact of steerable sheath visualization during catheter ablation for atrial fibrillation

    No full text
    Aims: Incorporating a steerable sheath that can be visualized using an electroanatomical mapping (EAM) system may allow for more efficient mapping and catheter placement, while reducing radiation exposure, during ablation procedures for atrial fibrillation (AF). This study evaluated fluoroscopy usage and procedure times when a visualizable steerable sheath was used compared with a non-visualizable steerable sheath for catheter ablation for AF. Methods and results: In this retrospective, observational, single-centre study, patients underwent catheter ablation for AF using a steerable sheath that is visualizable using the CARTO EAM (VIZIGO; n = 57) or a non-visualizable steerable sheath (n = 34). The acute procedural success rate was 100%, with no acute complications in either group. Use of the visualizable sheath vs. the non-visualizable sheath was associated with a significantly shorter fluoroscopy time [median (first quartile, third quartile), 3.4 (2.1, 5.4) vs. 5.8 (3.8, 8.6) min; P = 0.003], significantly lower fluoroscopy dose [10.0 (5.0, 20.0) vs. 18.5 (12.3, 34.0) mGy; P = 0.015], and significantly lower dose area product [93.0 (48.0, 197.9) vs. 182.2 (124.5, 355.0) μGy·m2; P = 0.017] but with a significantly longer mapping time [12.0 (9.0, 15.0) vs. 9.0 (7.0, 11.0) min; P = 0.004]. There was no significant difference between the visualizable and non-visualizable sheaths in skin-to-skin time [72.0 (60.0, 82.0) vs. 72.0 (55.5, 80.8) min; P = 0.623]. Conclusion: In this retrospective study, use of a visualizable steerable sheath for catheter ablation of AF significantly reduced radiation exposure vs. a non-visualizable steerable sheath. Although mapping time was longer with the visualizable sheath, the overall procedure time was not increased.</p

    Sex differences in one-year recurrence and all-cause mortality following catheter ablation of ventricular tachycardia in structural heart disease

    No full text
    Aims: We aimed to establish sex-specific predictors for 1-year VT recurrence and 1-year all-cause mortality in patients with structural heart disease undergoing catheter ablation. Methods: We analyzed data of 299 patients recorded in our structured registry. These included medical history, echocardiography parameters, laboratory results, VT properties, procedural data. Results: Out of the 299 patients, 34 (11%) were female. No significant difference was found between women and men in terms of VT recurrence (p = 0.74) or mortality (p = 0.07). In females, severe mitral regurgitation (MR), tricuspid regurgitation (TR), presentation with incessant VT, and preprocedural electrical storm (ES) were associated with increased risk of VT recurrence. Diabetes, implanted CRT, VT with hemodynamic instability, ES and advanced MR were the risk factors of mortality in women. ACEi/ARB use predicted a favorable outcome in both endpoints among females. In men, independent predictors of VT recurrence were the composite parameter of ES and multiple ICD therapies, presentation with incessant VT, severe MR, while independent predictors of mortality were age, LVEF, creatinine and previously implanted CRT. Conclusion: According to our investigation, there are pronounced sex differences in predictors of recurrence and mortality following VT ablation.</p

    Dual energy for pulmonary vein isolation using dual-energy focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 3-month results

    No full text
    Aims: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. Methods and results: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. Conclusion: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. Clinical trial registration: ClinicalTrials.gov Identifier: NCT05752487.</p
    corecore