7 research outputs found
Radioiodine therapy of differentiated thyroid cancer: radiologic impact of out-patient treatment with 100 to 150 mCi Iodine-131 activities
OBJETIVO: Determinar exposições decorrentes da radioiodoterapia ambulatorial do carcinoma diferenciado da tireoide (CDT) sobre os familiares dos pacientes e o meio ambiente. MÉTODOS: Administraram-se 100 a 150 mCi de (131I)NaI para tratamento ambulatorial de 20 pacientes com CDT. Monitorizaram-se com dosÃmetros termoluminescentes as doses de radiação recebidas por familiares (n = 27) e potenciais de dose nas residências. Também foram monitorizadas contaminação de superfÃcie e rejeitos radioativos. RESULTADOS: Registraram-se doses < 1,0 mSv em 26 acompanhantes e 2,8 mSv em um caso, inferiores ao aceitável para exposições médicas (5,0 mSv/procedimento). Excetuando-se o quarto dos pacientes (média = 0,69 mSv), determinou-se potencial de dose nas residências < 0,25 mSv. A contaminação de superfÃcies (4,2 Bq.cm-2) não ultrapassou nÃveis de liberação, sem representar riscos mesmo em simulações do pior cenário. Os rejeitos radioativos tiveram volume de 2,5 litros e atividade estimada em 90 µCi (média = 4,5 µCi/paciente). CONCLUSÕES: Não foi constatado impacto radiológico ao meio ambiente ou aos familiares de pacientes tratados ambulatorialmente com 100 a 150 mCi de iodo-131 e acompanhados por profissionais qualificados.PURPOSE:To evaluate exposure and dosimetry to family members and environment due to outpatient radioiodine therapy of differentiated thyroid carcinoma. METHODS: Twenty patients were treated with 100-150mCi of iodine-131 on an out-patient basis. Family members dosimetry (n = 27) and potential doses inside the house were measured with thermoluminescent dosimeters. Surface contamination and radioactive wastes were also monitored. RESULTS: Less than 1.0 mSv doses were found in 26 co-habitants and 2.8 mSv in a single case (inferior to the acceptable value of 5.0 mSv/procedure). Potential doses in the houses were inferior to 0.25 mSv, excluding the patients bedroom (mean value = 0.69 mSv). Surface contamination (mean = 4.2 Bq.cm-2) were below clearance levels. Radioactive wastes generated had a volume of 2.5 liters and a total activity estimated in 90 µCi, with a calculated exposure close to the background radiation levels. CONCLUSIONS: No radiological impact was detected after iodine therapy with 100-150 mCi on an out-patient basis followed by experienced professionals.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP
Pratical method of breast attenuation correction for cardiac spect
The breast attenuation effects on SPECT (Single Photon Emission Tomography) myocardium perfusion
procedures have been lately scope of continuous inquiry. The requested attenuation correction factors are
usually achieved by transmission analysis, making up the exposure of a standard external source to the SPECT, as a routine step. However, its high cost makes this methodology not fully available to the most of nuclear medicines services in Brazil and abroad. To overcome the problem, a new trend is presented in this work, implementing computational models to balance the breast attenuation effects on the left ventricle anterior wall, during myocardium perfusion scintigraphy procedures with SPECT. A neural network was put on in order to provide the attenuation correction indexes, based upon the following patients individual biotypes features: mass, age, height, chest and breast thicknesses, heart size, as well as the imparted activity intake levels
Applicability of the Appropriate use Criteria for Myocardial Perfusion Scintigraphy
Background: Appropriateness Criteria for nuclear imaging exams were created by American College of Cardiology (ACC) e American Society of Nuclear Cardiology (ASNC) to allow the rational use of tests. Little is known whether these criteria have been followed in clinical practice. Objective: To evaluate whether the medical applications of myocardial perfusion scintigraphy (MPS) in a private nuclear medicine service of a tertiary cardiology hospital were suitable to the criteria of indications proposed by the American medical societies in 2005 and 2009 and compare the level of indication of both. Methods: We included records of 383 patients that underwent MPS, November 2008 up to February 2009. Demographic characteristics, patient's origin, coronary risk factors, time of medical graduation and appropriateness criteria of medical applications were studied. The criteria were evaluated by two independent physicians and, in doubtful cases, defined by a medical expert in MPS. Results: Mean age was 65 ± 12 years. Of the 367 records reviewed, 236 (64.3%) studies were performed in men and 75 (20.4%) were internee. To ACC 2005, 255 (69.5%) were considered appropriate indication and 13 (3.5%) inappropriate. With ACC 2009, 249 (67.8%) were considered appropriate indications and 13 (5.2%) inappropriate. Conclusions: We observed a high rate of adequacy of medical indications for MPS. Compared to the 2005 version, 2009 did not change the results