11 research outputs found
Recommended from our members
Registration of the endoluminal surfaces of the colon derived from prone and supine CT colonography
Purpose: Computed tomographic (CT) colonography is a relatively new technique for detecting bowel cancer or potentially precancerous polyps. CT scanning is combined with three-dimensional (3D) image reconstruction to produce a virtual endoluminal representation similar to optical colonoscopy. Because retained fluid and stool can mimic pathology, CT data are acquired with the bowel cleansed and insufflated with gas and patient in both prone and supine positions. Radiologists then match visually endoluminal locations between the two acquisitions in order to determine whether apparent pathology is real or not. This process is hindered by the fact that the colon, essentially a long tube, can undergo considerable deformation between acquisitions. The authors present a novel approach to automatically establish spatial correspondence between prone and supine endoluminal colonic surfaces after surface parameterization, even in the case of local colon collapse.Methods: The complexity of the registration task was reduced from a 3D to a 2D problem by mapping the surfaces extracted from prone and supine CT colonography onto a cylindrical parameterization. A nonrigid cylindrical registration was then performed to align the full colonic surfaces. The curvature information from the original 3D surfaces was used to determine correspondence. The method can also be applied to cases with regions of local colonic collapse by ignoring the collapsed regions during the registration.Results: Using a development set, suitable parameters were found to constrain the cylindrical registration method. Then, the same registration parameters were applied to a different set of 13 validation cases, consisting of 8 fully distended cases and 5 cases exhibiting multiple colonic collapses. All polyps present were well aligned, with a mean (+/- std. dev.) registration error of 5.7 (+/- 3.4) mm. An additional set of 1175 reference points on haustral folds spread over the full endoluminal colon surfaces resulted in an error of 7.7 (+/- 7.4) mm. Here, 82% of folds were aligned correctly after registration with a further 15% misregistered by just onefold.Conclusions: The proposed method reduces the 3D registration task to a cylindrical registration representing the endoluminal surface of the colon. Our algorithm uses surface curvature information as a similarity measure to drive registration to compensate for the large colorectal deformations that occur between prone and supine data acquisitions. The method has the potential to both enhance polyp detection and decrease the radiologist's interpretation time. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3577603
Shortening osteotomy for the treatment of spinal neuroarthropathy following spinal cord injury. A case report and literature review
The development of Charcot’s arthropathy of the spine secondary to spinal cord injury is rare and reports in the literature concerning it’s surgical management are limited. Arthrodesis is the recommended treatment for painful and unstable neuropathic joints. Traditionally this involves extensive debridement of the affected joint with anterior and posterior instrumented fusion and autograft to bridge the defect. This paper reviews the reported surgical management of post-traumatic spinal neuroarthropathy in the recent literature and presents a case where sound fusion was achieved by a shortening osteotomy and end-to-end apposition of the fresh bleeding bony surfaces of the adjacent vertebral bodies. The patient reported marked improvement of symptoms post-operatively without any complications of surgery. CT scan at 13 months confirmed successful bony union. Clinical follow up was completed to 3 years. This technique eliminated the need for anterior surgery and extensive autograft thus reducing surgical morbidity