    Multicenter evaluation of the vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of gram-positive aerobic bacteria

    Get PDF
    Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.0 system (bioMérieux, Inc.) for the identification of aerobic Gram-positive bacteria. A total of 1,146 unique isolates, representing 13 genera and 42 species, were analyzed, and results were compared to those obtained by nucleic acid sequence-based identification as the reference method. For 1,063 of 1,146 isolates (92.8%), the Vitek MS provided a single identification that was accurate to the species level. For an additional 31 isolates (2.7%), multiple possible identifications were provided, all correct at the genus level. Mixed-genus or single-choice incorrect identifications were provided for 18 isolates (1.6%). Although no identification was obtained for 33 isolates (2.9%), there was no specific bacterial species for which the Vitek MS consistently failed to provide identification. In a subset of 463 isolates representing commonly encountered important pathogens, 95% were accurately identified to the species level and there were no misidentifications. Also, in all but one instance, the Vitek MS correctly differentiated Streptococcus pneumoniae from other viridans group streptococci. The findings demonstrate that the Vitek MS system is highly accurate for the identification of Gram-positive aerobic bacteria in the clinical laboratory setting

    Cost-Effectiveness Analysis of Diagnostic Options for Pneumocystis Pneumonia (PCP)

    Get PDF
    Diagnosis of Pneumocystis jirovecii pneumonia (PCP) is challenging, particularly in developing countries. Highly sensitive diagnostic methods are costly, while less expensive methods often lack sensitivity or specificity. Cost-effectiveness comparisons of the various diagnostic options have not been presented.We compared cost-effectiveness, as measured by cost per life-years gained and proportion of patients successfully diagnosed and treated, of 33 PCP diagnostic options, involving combinations of specimen collection methods [oral washes, induced and expectorated sputum, and bronchoalveolar lavage (BAL)] and laboratory diagnostic procedures [various staining procedures or polymerase chain reactions (PCR)], or clinical diagnosis with chest x-ray alone. Our analyses were conducted from the perspective of the government payer among ambulatory, HIV-infected patients with symptoms of pneumonia presenting to HIV clinics and hospitals in South Africa. Costing data were obtained from the National Institutes of Communicable Diseases in South Africa. At 50% disease prevalence, diagnostic procedures involving expectorated sputum with any PCR method, or induced sputum with nested or real-time PCR, were all highly cost-effective, successfully treating 77-90% of patients at 26−51perlife−yeargained.ProceduresusingBALspecimensweresignificantlymoreexpensivewithoutaddedbenefit,successfullytreating68−9026-51 per life-year gained. Procedures using BAL specimens were significantly more expensive without added benefit, successfully treating 68-90% of patients at costs of 189-232 per life-year gained. A relatively cost-effective diagnostic procedure that did not require PCR was Toluidine Blue O staining of induced sputum (25perlife−yeargained,successfullytreating6825 per life-year gained, successfully treating 68% of patients). Diagnosis using chest x-rays alone resulted in successful treatment of 77% of patients, though cost-effectiveness was reduced (109 per life-year gained) compared with several molecular diagnostic options.For diagnosis of PCP, use of PCR technologies, when combined with less-invasive patient specimens such as expectorated or induced sputum, represent more cost-effective options than any diagnostic procedure using BAL, or chest x-ray alone

    Red swamp crayfish: biology, ecology and invasion - an overview

    Full text link

    Detection of Group B Streptococcus Bacteria in LIM Enrichment Broth by Peptide Nucleic Acid Fluorescent In Situ Hybridization (PNA FISH) and Rapid Cycle PCR â–¿

    No full text
    The sensitivity, specificity, and negative and positive predictive values for the detection of group B Streptococcus (GBS) in 206 LIM enrichment broths by the use of subculture, GBS peptide nucleic acid fluorescent in situ hybridization (PNA FISH), and GBS PCR were 96.9%, 100%, 98.6%, and 100%; 98.4%, 100%, 99.3%, and 100%; and 100%, 100%, 100%, and 100%, respectively

    Use of Partial 16S rRNA Gene Sequencing for Identification of Legionella pneumophila and Non-pneumophila Legionella spp.

    No full text
    We examined 49 Legionella species, 26 L. pneumophila and 23 non-pneumophila Legionella spp., using partial 16S rRNA gene sequencing. This approach accurately identified all the L. pneumophila isolates, characterized all non-pneumophila Legionella isolates as such within this genus, and classified most (20/23; 87%) of the non-pneumophila Legionella isolates to the species level

    Multicenter Comparison of the VITEK 2 Yeast Susceptibility Test with the CLSI Broth Microdilution Reference Method for Testing Fluconazole against Candida spp.

    No full text
    A fully automated commercial antifungal susceptibility test system (VITEK 2 yeast susceptibility test; bioMerieux, Inc., Hazelwood, Mo.) was compared in three different laboratories with Clinical and Laboratory Standards Institute (CLSI) reference broth microdilution (BMD) method by testing two quality control strains and a total of 426 isolates of Candida spp. (103 to 135 clinical isolates in each laboratory plus 80 challenge isolates in one laboratory) against fluconazole. Reference BMD MIC endpoints were established after 24 and 48 h of incubation. VITEK 2 endpoints were determined spectrophotometrically after 10 to 26 h of incubation (mean, 13 h). Excellent essential agreement (within two dilutions) between the VITEK 2 and the 24- and 48-h BMD MICs was observed. The overall agreement values were 97.9 and 93.7%, respectively. Both intra- and interlaboratory agreement was 100%. The overall categorical agreement between VITEK 2 and BMD was 97.2% at the 24-h BMD time point and 88.3% at the 48-h BMD time point. Decreased categorical agreement at 48 h was attributed to trailing growth observed with Candida glabrata. The VITEK 2 system reliably detected fluconazole resistance among Candida spp. and demonstrated excellent quantitative and qualitative agreement with the reference BMD method

    Case of Synovitis Potentially Caused by Dolosigranulum pigrum

    No full text
    We report a case of synovitis in a 64-year-old man who developed the infection while on steroid therapy for rheumatoid arthritis. Dolosigranulum pigrum, a gram-positive catalase-negative coccus, was isolated from two sets of blood cultures prior to antibiotic therapy. The patient was treated with 4 weeks of appropriate antibiotics, and the synovial inflammation resolved. Although synovial aspirates were never positive for any bacteria or fungi, the timing of positive blood cultures and absence of other pathogens suggest the possible etiology as D. pigrum

    Multicenter Comparison of the VITEK 2 Antifungal Susceptibility Test with the CLSI Broth Microdilution Reference Method for Testing Amphotericin B, Flucytosine, and Voriconazole against Candida spp.â–¿

    No full text
    A fully automated commercial antifungal susceptibility test system (VITEK 2; bioMérieux, Inc., Hazelwood, MO) was compared in three different laboratories with the Clinical and Laboratory Standards Institute (formerly the NCCLS) reference broth microdilution method (BMD) by testing 2 quality control strains, 10 reproducibility strains, and 426 isolates of Candida spp. against amphotericin B, flucytosine, and voriconazole. Reference BMD MIC endpoints were established after 24 and 48 h of incubation. VITEK 2 system MIC endpoints were determined spectrophotometrically after 9.1 to 27.1 h of incubation (mean, 12 to 14 h). Excellent essential agreement (within 2 dilutions) between the VITEK 2 system and the 24- and 48-h BMD MICs was observed for all three antifungal agents: amphotericin B, 99.1% and 97%, respectively; flucytosine, 99.1% and 98.8%, respectively; and voriconazole, 96.7% and 96%, respectively. Both intra- and interlaboratory agreements were >98% for all three drugs. The overall categorical agreements between the VITEK 2 system and BMD for flucytosine and voriconazole were 98.1 to 98.6% at the 24-h BMD time point and 96.9 to 97.4% at the 48-h BMD time point. The VITEK 2 system reliably detected flucytosine and voriconazole resistance among Candida spp. and demonstrated excellent quantitative and qualitative agreement with the reference BMD method

    Evaluation of ColorPAC Giardia/Cryptosporidium Rapid Assay and ProSpecT Giardia/Cryptosporidium Microplate Assay for Detection of Giardia and Cryptosporidium in Fecal Specimens

    No full text
    Detection of Giardia and Cryptosporidium in clinical stool specimens using the ColorPAC and ProSpecT enzyme immunoassays revealed 98.7% agreement for Giardia detection and 98.1% agreement for Cryptosporidium detection. Sensitivities were uniformly 100%. The specificities of the ColorPAC immunoassay for Giardia and Cryptosporidium detection were 100 and 99.5%, respectively, and those for the ProSpecT assay were 98.4 and 98.6%, respectively. The false-positive reactions with the ProSpecT assay occurred with specimens that were grossly bloody
    • …