433 research outputs found

    Test of ID carbon-carbon composite prototype tiles for the SPIDER diagnostic calorimeter

    Get PDF
    Additional heating will be provided to the thermonuclear fusion experiment ITER by injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction at Consorzio RFX in Padova (Italy), the production of negative ions will be studied and optimised. To this purpose the STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) diagnostic will be used to characterise the SPIDER beam during short operation (several seconds) and to verify if the beam meets the ITER requirement regarding the maximum allowed beam non-uniformity (below \ub110%). The most important measurements performed by STRIKE are beam uniformity, beamlet divergence and stripping losses. The major components of STRIKE are 16 1D-CFC (Carbon matrix-Carbon Fibre reinforced Composite) tiles, observed at the rear side by a thermal camera. The requirements of the 1D CFC material include a large thermal conductivity along the tile thickness (at least 10 times larger than in the other directions); low specific heat and density; uniform parameters over the tile surface; capability to withstand localised heat loads resulting in steep temperature gradients. So 1D CFC is a very anisotropic and delicate material, not commercially available, and prototypes are being specifically realised. This contribution gives an overview of the tests performed on the CFC prototype tiles, aimed at verifying their thermal behaviour. The spatial uniformity of the parameters and the ratio between the thermal conductivities are assessed by means of a power laser at Consorzio RFX. Dedicated linear and non-linear simulations are carried out to interpret the experiments and to estimate the thermal conductivities; these simulations are described and a comparison of the experimental data with the simulation results is presented

    Characterization of Cs-free negative ion production in the ion source SPIDER by Cavity Ring-Down Spectroscopy

    Full text link
    The Neutral beam Injectors of the ITER experiment will be based on negative ion sources for the generation of beams composed by 1 MeV H/D particles. The prototype of these sources is currently under testing in the SPIDER experiment, part of the Neutral Beam Test Facility of Consorzio RFX, Padua, Italy. Among the targets of the experimentation in SPIDER, it is of foremost importance to maximize the beam current density extracted from the source acceleration system. The SPIDER operating conditions can be optimized thanks to a Cavity Ring-down Spectroscopy diagnostic, which is able to give line-integrated measurements of negative ion density in proximity of the acceleration system apertures. Regarding the diagnostic technique, this work presents a phenomenon of drift in ring down time measurements, which develops in a time scale of few hours. This issue may significantly affect negative ion density measurements for plasma pulses of 1 h duration, as required by ITER. Causes and solutions are discussed. Regarding the source performance, this paper presents how negative ion density is influenced by the RF power used to sustain the plasma, and by the magnetic filter field present in SPIDER to limit the amount of co-extracted electrons. In this study, SPIDER was operated in hydrogen and deuterium, in Cs-free conditions.Comment: 9 pages, 5 figures. Accepted manuscript of a published articl

    First Beam Characterization by Means of Emission Spectroscopy in the NIO1 Experiment

    Full text link
    The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation dedicated to the ITER neutral beam test facility. Many diagnostics are installed in NIO1 to characterize the source and the extracted negative ion beam. Among them, Beam Emission Spectroscopy (BES) has been used in NIO1 to measure the divergence and the uniformity of the beam, together with the fraction of beam ions which was neutralized inside the acceleration system. The diagnostic method is based on the analysis of the Doppler shifted HαH_\alpha photons emitted by the fast beam particles and collected along a line of sight. The article presents the experimental setup and the analysis algorithms of the BES diagnostic, together with a discussion of the first measurements and of their correlation with the operational parameters.Comment: 3 pages, 2 figures. Contributed paper for the ICIS 2017 conference. Accepted manuscript of a published pape

    Electron Density and Temperature in NIO1 RF Source Operated in Oxygen and Argon

    Full text link
    The NIO1 experiment, built and operated at Consorzio RFX, hosts an RF negative ion source, from which it is possible to produce a beam of maximum 130 mA in H- ions, accelerated up to 60 kV. For the preliminary tests of the extraction system the source has been operated in oxygen, whose high electronegativity allows to reach useful levels of extracted beam current. The efficiency of negative ions extraction is strongly influenced by the electron density and temperature close to the Plasma Grid, i.e. the grid of the acceleration system which faces the source. To support the tests, these parameters have been measured by means of the Optical Emission Spectroscopy diagnostic. This technique has involved the use of an oxygen-argon mixture to produce the plasma in the source. The intensities of specific Ar I and Ar II lines have been measured along lines of sight close to the Plasma Grid, and have been interpreted with the ADAS package to get the desired information. This work will describe the diagnostic hardware, the analysis method and the measured values of electron density and temperature, as function of the main source parameters (RF power, pressure, bias voltage and magnetic filter field). The main results show that not only electron density but also electron temperature increase with RF power; both decrease with increasing magnetic filter field. Variations of source pressure and plasma grid bias voltage appear to affect only electron temperature and electron density, respectively.Comment: 7 pages 4 figures. Contributed paper for the NIBS 2016 conference. Accepted manuscrip

    Complete compensation of criss-cross deflection in a negative ion accelerator by magnetic technique

    Get PDF
    During 2016, a joint experimental campaign was carried out by QST and Consorzio RFX on the Negative Ion Test Stand (NITS) at the QST Naka Fusion Institute, Japan, with the purpose of validating some design solutions adopted in MITICA, which is the full-scale prototype of the ITER NBI, presently under construction at Consorzio RFX, Padova, Italy. The main purpose of the campaign was to test a novel technique, for suppressing the beamlet criss-cross magnetic deflection. This new technique, involving a set of permanent magnets embedded in the Extraction Grid, named Asymmetric Deflection Compensation Magnets (ADCM), is potentially more performing and robust than the traditional electrostatic compensation methods. The results of this first campaign confirmed the effectiveness of the new magnetic configuration in reducing the criss-cross magnetic deflection. Nonetheless, contrary to expectations, a complete deflection correction was not achieved. By analyzing in detail the results, we found indications that a physical process, taking place just upstream of the plasma grid, was giving an important contribution to the final deflection of the negative ion beam. This process appears to be related to the drift of negative ions inside the plasma source, in the presence of a magnetic field transverse to the extraction direction, and results in a non-uniform ion current density extracted at the meniscus. Therefore, the numerical models adopted in the design were improved by including this previously disregarded effect, so as to obtain a much better matching with the experimental results. Based on the results of the first campaign, new permanent magnets were designed and installed on the Extraction Grid of NITS. A second QST-Consorzio RFX joint experimental campaign was then carried out in 2017, demonstrating the complete correction of the criss-cross deflection and confirming the validity of the novel magnetic configuration and of the hypothesis behind the new models. This contribution presents the results of the second joint experimental campaign on NITS along with the overall data analysis of both campaigns, and the description of the improved models. A general picture is given of the relation among magnetic field, beam energy, meniscus non-uniformity and beamlet deflection, constituting a useful database for the design of future machines

    Numerical and experimental investigations of a microwave interferometer for the negative ion source SPIDER

    Full text link
    The electron density close to the extraction grids and the co-extracted electrons represent a crucial issue when operating negative ion sources for fusion reactors. An excessive electron density in the plasma expansion region can indeed inhibit the negative ion production and introduce potentially harmful electrons in the accelerator. Among the set of plasma and beam diagnostics proposed for SPIDER upgrade, a heterodyne microwave (mw) interferometer at 100 GHz is being explored as a possibility to measure electron density in the plasma extraction region. The major issue in applying this technique in SPIDER is the poor accessibility of the probing microwave beam through the source metal walls and the long distance of 4 m at which mw modules should be located outside the vacuum vessel. Numerical investigations in a full-scale geometry showed that the power transmitted through the plasma source apertures was sufficient for the microwave module sensitivity. An experimental proof-of-principle of the setup was then performed. The microwave system was tested on an experimental full-scale test-bench mimicking SPIDER viewports accessibility constraints, including the presence of a SPIDER-like plasma. The outcome of first tests revealed that, despite the geometrical constraints, in certain conditions, the electron density measurements are possible. The main issue arises from decoupling the one-pass signal from spurious multipaths generated by mw beam reflections, requiring signal cross correlation analysis. These preliminary tests demonstrate that despite the 4 m distance between the mw modules and the presence of metal walls, plasma density measurement is possible when the 80-mm diameter ports are available. In this contribution, we discuss the numerical simulations, the preliminary experimental tests and suggest design upgrades of the interferometric setup to enhance signal transmission

    About the parabolic relation existing between the skewness and the kurtosis in time series of experimental data

    Full text link
    In this work we investigate the origin of the parabolic relation between skewness and kurtosis often encountered in the analysis of experimental time-series. We argue that the numerical values of the coefficients of the curve may provide informations about the specific physics of the system studied, whereas the analytical curve per se is a fairly general consequence of a few constraints expected to hold for most systems.Comment: To appear in Physica Script

    Negative ion density in the ion source SPIDER in Cs free conditions

    Full text link
    The SPIDER experiment, operated at the Neutral Beam Test Facility of Consorzio RFX, Padua, hosts the prototype of the H-/D- ion source for the ITER neutral beam injectors. The maximization of the ion current extracted from the source and the minimization of the amount of co-extracted electrons are among the most relevant targets to accomplish. The Cavity Ring-Down Spectroscopy diagnostic measures the negative ion density in the source close to the acceleration system, so as to have feedback information to optimize the source parameters and to maximize the amount of negative ions that can be extracted at optimal beam divergence. This work shows how the magnetic filter field and the bias currents, present in SPIDER to limit the amount of co-extracted electrons and the electron-ion stripping reactions, affect the density of negative ions available for extraction. Moreover, the influence of the extraction process on the density of negative ions available for extraction is also presented. In this study SPIDER was operated in hydrogen and deuterium in Cs-free conditions, therefore negative ions were mostly produced by reactions in the plasma volume.Comment: 13 pages, 8 figures. Preprint of a published pape
    • …
    corecore