6 research outputs found

    АНАЛІЗ ПРОБЛЕМ ТА МОЖЛИВОСТЕЙ ВІДТВОРЕННЯ АРТИКУЛЯЦІНИХ РУХІВ ЩЕЛЕПИ У ЦИФРОВОМУ СЕРЕДОВИЩІ

    Get PDF
    Introduction. The use of virtual articulators, which are essentially software, greatly enhances the effectiveness of planning and implementing stages of complex dental rehabilitation with the ability to completely translate patient data (not only anatomical but also functional) into a digital format.The aim of study. Carry out an analysis of design and simulation systems for jaw kinematic parameters reproduction, basic principles of the architecture of existing software aimed at reproducing articulation components and constructing individualized occlusion patterns during patient-oriented prosthetic treatment.Materials and methods. The search for publications in electronic databases (PubMedCentral (PMC), BioMed Central, InTech, MEDLINE / PubMed, the Public Library of Science One (PloS)) was carried out in accordance with the Medical Subject Headings (MeSH) descriptors, which are peculiar headings categorized by the hierarchy system. Additionally, the analysis of references in already pre-made system reviews related to the objectives of this study and other review publications adjacent to them was provided.Results. The systematic review of the principles of digital modeling of articulation schemes with different initial conditions confirmed the possibility of their practical application during the manufacture of prosthetic elements with individualized occlusive surfaces, thus ensuring the achievement of the best results of dental rehabilitation.Conclusions. A systematic review of the main possibilities for reproduction jaw articulation movements in the digital environment is the primary stage in the development of an own model of a digital atticulator to address specific clinical problems associated with prosthetic retreatment of patients with present occlusive dysfunctions.Введение. Использование виртуальных артикуляторов, которые по сути представляют собой программное обеспечение, значительно повышает эффективность планирования и реализация этапов комплексной стоматологической реабилитации с возможностью полного перевода данных пациента (не только анатомических, но и функциональных) в цифровой формат.Цель исследования. Провести анализ систем дизайна и имитации кинематических параметров челюсти, основных принципов архитектуры имеющегося программного обеспечения направленного на воспроизводство артикуляционных составляющих и построение индивидуализированных окклюзионных схем в ходе пациент-ориентированного ортопедического лечения.Материалы и методы. Поиск публикаций в электронных базах данных (PubMedCentral (PMC), BioMed Central, InTech, MEDLINE / PubMed, Public Library of Science One (PloS)) осуществлялся согласно дескрипторов Medical Subject Headings (MeSH), представляющих собой своеобразные заголовки, категоризированных по системе иерархии. Дополнительно проводился анализ ссылок в уже предварительно проведенных системных обзорах, касающихся цели данного исследования, и других обзорных публикациях, смежных с ними.Результаты исследования. Проведенный системный обзор принципов цифрового моделирования артикуляционных схем с различными исходными условиями подтвердил возможность их практического применения при изготовлении протетических элементов с индивидуализированными окклюзионными поверхностями, обеспечивая таким образом достижение наиболее оптимальных результатов стоматологической реабилитации.Выводы. Системный обзор основных возможностей воспроизведения артикуляционных движений челюсти в цифровой среде является первичным этапом разработки собственной модели цифрового атикулятора для решения конкретных клинических проблем, связанных с повторным протезированием пациентов с имеющимися окклюзионными дисфункциями.Вступ. Використання віртуальних артикуляторів, що по суті представляють собою програмне забезпечення, значно підвищує ефективність планування та реалізація етапів комплексної стоматологічної реабілітації з можливістю повного переведення даних пацієнта (не тільки анатомічних, а й функціональних) у цифровий формат.Мета дослідження. Провести аналіз систем дизайну та імітації кінематичних параметрів щелепи, основних принципів архітектури наявного програмного забезпечення спрямованого на відтворення артикуляційних складових та побудову індивідуалізованих оклюзійних схем в ході пацієнт-орієнтованого ортопедичного лікування.Матеріали та методи. Пошук публікацій у електронних базах даних (PubMedCentral (PMC), BioMed Central, InTech, MEDLINE/ PubMed, Public Library of Science One (PloS)) здійснювався згідно дескрипторів Medical Subject Headings (MeSH), що становлять собою своєрідні заголовки, категоризовані за системою ієрархії. Додатково проводився аналіз посилань в уже попередньо проведених системних оглядах, що стосувалися мети даного дослідження, та інших оглядових публікаціях, суміжних із ними.Результати дослідження. Проведений системний огляд принципів цифрового моделювання артикуляційних схем з різними вихідними умовами підтвердив можливість їх практичного застосування під час виготовлення протетичних елементів з індивідуалізованими оклюзійними поверхнями, забезпечуючи таким чином досягнення найбільш оптимальних результатів стоматологічної реабілітації.Висновки. Системний огляд основних можливостей відтворення артикуляційних рухів щелепи в цифровому середовищі є первинним етапом розробки власної моделі цифрового атикулятора для вирішення конкретних клінічних проблем пов’язаних із повторним протезуванням пацієнтів із наявними оклюзійними дисфункціями

    Аналіз методів оцінки та впливу полірованості композитних матеріалів на функціональний прогноз реставрацій

    Get PDF
    Summary. Among the proposed USPHS criteria approved by FDI, the level of gloss and polishing of restorations plays a key role in preventing not only such complications  as disocorporations or changes in their texture in the future, but also preventing secondary caries and sealing disintegration, since areas with high roughness play the role of retention points for the accumulation of bacterial plaque and the further progression of the above-described complications.The aim of the study – to analyze the methods for assessing the quality of polishing composite restorations and to determine the role of influence roughness factor of their surface on the prediction of their functioning and change of color stability parameters, formation of biofilm and shine.Materials and Methods. Search of publications related to the topic of this analysis was conducted by the Google Scholar search engine by the keywords "roughness", "polishing", "composite restorations" and their analogues in English. The depth of search, taking into account the age of key articles, determined by the level of their citation in later periodicals, did not exceed 15 years. In order to organize the received data, Microsoft Excel 2016 (Microsoft Office) table editor was used to group  pre-selected articles based on the results of the provided content analysis.Results and Discussion. In the course of the analysis, it was established that the basic laboratory methods for assessing the roughness of the restoration surface, as an indicator of the quality of polishing, are atomic force microscopy, scanning electron microscopy and profilometry. Most often, in order to verify the aforementioned parameter in the analyzed studies, the Ra value of mean arithmetic deviation of the profile was used, on the basis of which analysis it was possible to determine the dependence of the possibilities for achieving the corresponding level of restoration polishing on the structure of the composite material used, the system and phases of polishing, and the tribological nature of the interaction of the polishing system and the surface of the restoration.Conclusions. The results of the analysis show that the data obtained in the course of previous clinical and laboratory studies dedicated to the effect of polishing on various restoration parameters are debatable and a more specific systematization is required, with the selection of the investigated aspects of brightness, roughness, color stability and functional prediction changes due to the polishing method in separate independent subjects for research, with further phased combination of them after obtaining unambiguous numerical data, subjected to appropriate objective interpretation.Резюме. Среди предложенных критериев USPHS, одобренных FDI, уровень блеска и полированости реставраций играет одно из ключевых значений для предупреждения не только таких осложнений как дисколорация или изменение их текстуры в будущем, но и для профилактики вторичного кариеса и дезинтеграции пломбы, поскольку площади с повышенной шероховатостью играют роль ретенционных пунктов для накопления бактериального налета и дальнейшего прогрессирования вышеописанных осложнений. Цель исследования – провести анализ методов оценки качества полировки композитных реставраций и определить роль влияния фактора шероховатости их поверхности на прогноз их функционирования и изменение параметров цветоустойчивости, формирование биопленки и блеска. Материалы и методы. Поиск публикаций смежных с темой данного анализа проводился в поисковой системе Google Scholar по ключевым словам «шероховатость», «полированисть», «композитные реставрации» и их аналогов на английском языке. Глубина поиска с учетом возраста ключевых статей, которые определялись по уровню цитируемости в более поздних периодических изданиях, не превышала 15 лет. С целью систематизации полученных данных использовали табличный редактор Microsoft Excel 2016 (Microsoft Office), в котором проводили группировку предварительно отобранных статей по результатам контент-анализа. Результаты и их обсуждение. В ходе проведенного анализа было установлено, что основными лабораторными методами для оценки параметра шероховатости поверхности реставрации, как показателя качества полированости, выступают атомно-силовая микроскопия, сканирующая электронная микроскопия и профилометрия. Чаще всего с целью верификации вышеупомянутого параметра в проанализированных исследованиях использовали показатель Ra – среднего арифметического отклонения профиля, на основе анализа которого удалось установить зависимость возможностей достижения соответствующего уровня полированости реставраций от структуры используемого композитного материала, системы и этапности полировки, трибологической природы взаимодействия системы полировки и поверхности реставрации. Выводы. Результаты проведенного анализа свидетельствуют о том, что данные получены в ходе предыдущих клинических и лабораторных исследований влияния и эффекта полировки на различные параметры реставраций являются дискуссионными и требуются более конкретной систематизации с выделением исследуемых аспектов изменения блеска, шероховатости, цветоустойчивости и функционального прогноза от метода полировки в отдельные независимые тематики для исследований, с поэтапным их сочетанием после получения однозначных многочисленных данных, подвергающихся соответствующей объективной интерпретации.Резюме. Серед запропонованих критеріїв USPHS, одобрених FDI, рівень блиску та полірованості реставрацій відіграє одне з ключових значень для попередження не тільки таких ускладнень як дисколорації чи зміна їх текстури в майбутньому, а й для профілактики вторинного карієсу та дезінтеграції пломби, оскільки площі з підвищеною шорсткістю відіграють роль ретенційних пунктів для накопичення бактеріального нальоту та подальшого прогресування вищеописаних ускладнень.Мета дослідження – провести аналіз методів оцінки якості полірування композитних реставрацій та визначити роль впливу фактора шорсткості їх поверхні на прогноз функціонування та зміну параметрів кольоростійкості, формування біоплівки та блиску.  Матеріали і методи. Пошук публікацій, суміжних із темою даного аналізу, проводили у пошуковій системі Google Scholar за ключовими словами «шорсткість», «полірованість», «композитні реставрації» та їх аналогів англійською мовою. Глибина пошуку з урахуванням віку ключових статей, що визначалися за рівнем цитованості у пізніших періодичних виданнях, не перевищувала 15 років. З метою систематизації отриманих даних використовували табличний редактор Microsoft Excel 2016 (Microsoft Office), у якому відбувалось групування попередньо відібраних статей за результатами контент-аналізу.Результати досліджень та їх обговорення. В ході проведеного аналізу було встановлено, що основними лабораторними методами для оцінки параметру шорсткості поверхні реставрації як показника якості полірованості, виступають атомно-силова мікроскопія, скануюча електронна мікроскопія та профілометрія. Найчастіше з метою верифікації вищезгаданого параметру в проаналізованих дослідженнях використовували показник Ra – середнього арифметичного відхилення профілю, на основі аналізу якого вдалось встановити залежність можливостей досягнення відповідного рівня полірованості реставрацій від структури використовуваного композитного матеріалу, системи та етапності полірування, трибологічної природи взаємодії системи полірування та поверхні реставрації.Висновки. Результати проведеного аналізу свідчать про те, що дані, отримані в ході попередніх клінічних та лабораторних досліджень щодо впливу та ефекту полірування на різні параметри реставрацій, є дискусійними та потребуються більш конкретної систематизації з виокремленням досліджуваних аспектів змін блиску, шорсткості, кольоростійкості та функціонального прогнозу від методу полірування в окремі незалежні тематики для досліджень, з поетапним їх поєднанням після отримання однозначних чисельних даних, що піддаються відповідній об’єктивній інтерпретації

    Hangzhou, China: West Lake [011]

    No full text
    Photograph (close-up) of plant, Huagang Park, West Lake, Hangzhou, ChinaPlant, Huagang Park, Hangzhou (Hangchow), China
    corecore