52 research outputs found

    Effects of an Alpha-4 Integrin Inhibitor on Restenosis in a New Porcine Model Combining Endothelial Denudation and Stent Placement

    Get PDF
    Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where restenosis is assessed after endothelial abrasion of the arterial wall or stent implantation. We combined endothelial cell denudation and implantation of stents to develop a new clinically relevant porcine model of restenosis, and used this model to determine the effects of an α4 integrin inhibitor, ELN 457946, on restenosis. Balloon-angioplasty endothelial cell denudation and subsequent implantation of bare metal stents in the left anterior descending coronary, iliac, and left common carotid arteries was performed in domestic pigs, treated with vehicle or ELN 457946, once weekly via subcutaneous injections, for four weeks. After 1 month, histopathology and morphometric analyses of the arteries showed complete healing and robust, consistent restenotic response in stented arteries. Treatment with ELN 457946 resulted in a reduction in the neointimal response, with decreases in area percent stenosis between 12% in coronary arteries and 30% in peripheral vessels. This is the first description of a successful pig model combining endothelial cell denudation and bare metal stent implantation. This new double injury model may prove particularly useful to assess pharmacological effects of drug candidates on restenosis, in coronary and/or peripheral arteries. Furthermore, the ELN 457946 α4 integrin inhibitor, administered subcutaneously, reduced inflammation and restenosis in stented coronary and peripheral arteries in pigs, therefore representing a promising systemic therapeutic approach in reducing restenosis in patients undergoing angioplasty and/or stent implantation

    Clin Transl Sci

    Get PDF
    Adenosine boasts promising preclinical and clinical data supporting a vital role in modulating vascular homeostasis. Its widespread use as a diagnostic and therapeutic agent have been limited by its short half-life and complex biology, though adenosine-modulators have shown promise in improving vascular healing. Moreover, circulating adenosine has shown promise in predicting cardiovascular (CV) events. We sought to delineate whether circulating plasma adenosine levels predict CV events in patients undergoing invasive assessment for coronary artery disease. Patients undergoing invasive angiography had clinical data prospectively recorded in the Cardiovascular and Percutaneous ClInical TriALs (CAPITAL) revascularization registry and blood samples collected in the CAPITAL Biobank from which adenosine levels were quantified. Tertile-based analysis was used to assess prediction of major adverse cardiovascular events (MACE; composite of death, myocardial infarction, unplanned revascularization, and cerebrovascular accident). Secondary analyses included MACE subgroups, clinical subgroups and adenosine levels. There were 1,815 patients undergoing angiography who had blood collected with adenosine quantified in 1,323. Of those quantified, 51.0% were revascularized and 7.3% experienced MACE in 12 months of follow-up. Tertile-based analysis failed to demonstrate any stratification of MACE rates (log rank, P = 0.83), when comparing low-to-middle (hazard ratio (HR) 1.10, 95% confidence interval (CI) 0.68-1.78, P = 0.70) or low-to-high adenosine tertiles (HR 0.95, 95% CI 0.56-1.57, P = 0.84). In adjusted analysis, adenosine similarly failed to predict MACE. Finally, adenosine did not predict outcomes in patients with acute coronary syndrome nor in those revascularized or treated medically. Plasma adenosine levels do not predict subsequent CV outcomes or aid in patient risk stratification

    Efficacy and Safety of Abciximab in Diabetic Patients Who Underwent Percutaneous Coronary Intervention with Thienopyridines Loading: A Meta-Analysis

    Get PDF
    It has been controversial whether abciximab offered additional benefits for diabetic patients who underwent percutaneous coronary intervention (PCI) with thienopyridines loading.MEDLINE, EMBASE, the Cochrane library clinical trials registry, ISI Science Citation Index, ISI Web of Knowledge and China National Knowledge Infrastructure (CNKI) were searched, supplemented with manual-screening for relevant publications. Quantitative meta-analyses were performed to assess differences between abciximab groups and controls with respect to post-PCI risk of major cardiac events (MACEs), angiographic restenosis and bleeding complications.<0.001), whereas major bleedings rate was similar (RR: 0.83, 95% CI: 0.27–2.57).Concomitant dosing of abciximab and thienopyridines provides no additional benefit among diabetic patients who underwent PCI; this conclusion, though, needs further confirmation in larger studies

    Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type

    Get PDF
    Aim To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Methods and results Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). Conclusion A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957

    Viability of Hybrid Systems: A Controllability Operator Approach

    No full text
    The problem of viability of hybrid systems is considered in this work. A model for a hybrid system is developed including a means of including three forms of uncertainty: transition dynamics, structural uncertainty, and parametric uncertainty. A computational basis for viability of hybrid systems is developed and applied to three control law classes. An approach is developed for robust viability based on two extensions of the controllability operator. The three-tank example is examined for both the viability problem and robust viability problem. The theory is applied through simulation to an active magnetic bearing system and to a batch polymerization process showing that viability can be satisfied in practice. The problem of viable attainability is examined based on the controllability operator approach introduced by Nerode and colleagues. Lastly, properties of the controllability operator are presented

    Association between plasminogen activator inhibitor-1 and cardiovascular events: a systematic review and meta-analysis

    No full text
    Abstract Background Small studies have implicated plasminogen activator inhibitor-1 (PAI-1) as a predictor of cardiovascular events; however, these findings have been inconsistent. We sought out to examine the potential role of PAI-1 as a marker for major adverse cardiovascular events (MACE). Methods We systematically reviewed all indexed studies examining the association between PAI-1 and MACE (defined as death, myocardial infarction, or cerebrovascular accident) or restenosis. EMBASE, Web of Science, Medline, and the Cochrane Library were searched through October 2016 to identify relevant studies, supplemented by letters to authors and review of citations. Studies reporting the results of PAI-1 antigen and/or activity levels in association with MACE in human subjects were included. Results Of 5961 articles screened, we identified 38 articles published between 1991 to 2016 that reported PAI-1 levels in 11,557 patients. In studies that examined PAI-1 antigen and activity levels, 15.1% and 29.6% of patients experienced MACE, respectively. Patients with MACE had higher PAI-1 antigen levels with a mean difference of 6.11 ng/mL (95% CI, 3.27-8.96). This finding was similar among patients with and without known coronary artery disease. Comparatively, studies that stratified by PAI-1 activity levels were not associated with MACE. In contrast, studies of coronary restenosis suggest PAI-1 antigen and activity levels are negatively associated with MACE. Conclusions Elevated plasma PAI-1 antigen levels are associated with MACE. Definitive studies are needed to ascertain if PAI-1 acts simply as a marker of risk or if it is indeed a bona fide therapeutic target
    • …