3,163 research outputs found

    Living with helicopter noise : evaluating sound insulation techniques for domestic dwellings using real helicopters

    Get PDF
    Specific remedial works designed to improve sound installation and reduce the noise level produced by helicopters inside dwellings are described. The theoretical problems and practical solutions to installing high performance acoustic insulation to a traditional property in the UK are presented. A novel application of ISO 140-5 is presented using real helicopters to measure sound insulation in-situ in the presence of multiple flanking transmission paths. Dedicated field trials to evaluate the performance of such acoustic double-glazing and associated modifications systems were performed and the precautions taken to minimise measurement uncertainties over the extended time period of the trials are detailed. The field trials involved the use of military training helicopters following selected flight paths around the property while noise level measurements were made internally and externally, before and after replacement of the existing single glazed windows and attenuated ventilation units were installed. The results show that after replacing the main windows with acoustic insulated glazing units, insulation levels of 40dB or above are achieved in most rooms. The results also illustrate the importance of effectively addressing ventilation when windows are replaced. It is concluded that despite complications due to sound flanking and regulatory ventilation, the use of acoustic double-glazing units and properly attenuated ventilation units can effectively reduce helicopter noise in suitable dwellings

    Annoyance due to railway vibration at different times of the day

    Get PDF
    The time of day when vibration occurs is considered as a factor influencing the human response to vibration. The aim of the present paper is to identify the times of day during which railway vibration causes the greatest annoyance, to measure the differences between annoyance responses for different time periods and to obtain estimates of the time of day penalties. This was achieved using data from case studies comprised of face-to-face interviews and internal vibration measurements (N=755). Results indicate that vibration annoyance differs with time of day and that separate time of day weights can be applied when considering exposure–response relationships from railway vibration in residential environments

    Logic-controlled solid state switchgear for 270 volts dc

    Get PDF
    A feasibility study to design and demonstrate solid state switchgear in the form of circuit breakers and a power transfer switch is described. The switchgear operates on a nominal 270 V dc circuit and controls power to a load of up to 15 amperes. One circuit breaker may be interconnected to a second breaker to form a power transfer switch. On-off and transfer functions of the breakers or the transfer switch are remotely controlled. A number of reclosures with variable time delay between tripout and reclosure are programmed and controlled by integrated analog and COSMOS logic circuits. A unique commutation circuit, that generates only minimal transient disturbance to either source or load, was developed to interrupt current flow through the main SCR switching element. Laboratory tests demonstrated performance of the solid state circuit breakers over specified voltage and temperature ranges

    Gamma ray emission from the region of the galactic center

    Get PDF
    A combination nuclear emulsion-spark chamber gamma ray (E=100 MeV) telescope was used to study the region of sky that includes the Galactic Center. 95% confidence upper limits on the flux from the reported sources G gamma 2 - 3 and Sgr gamma-1 were placed at 4.4 and 8.8 x 10 to the minus 5th power protons/sq cm-sec, and a similar limit on the emission from the Galactic Center as a point source (plus or minus .75 degrees) was placed at 3.3 x 10 to the minus 5th power protons/sq cm-sec. No enhanced emission was observed from the Galactic Plane (plus or minus 6 degrees) and an upper limit of 2 x 10 to the minus 4th power protons/sq cm-sec rad/ was obtained

    Human response to vibration in residential environments (NANR209), technical report 3 : calculation of vibration exposure

    Get PDF
    The Technical Report 3 describes the research undertaken to develop a methodology by which human exposure to vibration in residential environments can be calculated. That work has carried out by the University of Salford supported by the Department of environment food and rural affairs (Defra). The overall aim of the project is to derive exposure-response relationships for human vibration in residential environments. This document in particular focuses on the methods used to calculate vibration exposure from measured vibration signals due to different sources. The main objective of this report is to describe the different approaches used for calculating the different source-specific exposure. Reported here are findings obtained and a description of the feasibility of the methods used for evaluating exposure for different sources. In addition, an evaluation of the uncertainty related to the exposure calculation is considered
    • …
    corecore