32 research outputs found

    Esophageal and Gastric Malignancies After Bariatric Surgery: a Retrospective Global Study

    Get PDF
    Background: Bariatric surgery can influence the presentation, diagnosis, and management of gastrointestinal cancers. Esophagogastric (EG) malignancies in patients who have had a prior bariatric procedure have not been fully characterized. Objective: To characterize EG malignancies after bariatric procedures. Setting: University Hospital, United Kingdom. Methods: We performed a retrospective, multicenter observational study of patients with EG malignancies after bariatric surgery to characterize this condition. Results: This study includes 170 patients from 75 centers in 25 countries who underwent bariatric procedures between 1985 and 2020. At the time of the bariatric procedure, the mean age was 50.2 ± 10 years, and the mean weight 128.8 ± 28.9 kg. Women composed 57.3% (n = 98) of the population. Most (n = 64) patients underwent a Roux-en-Y gastric bypass (RYGB) followed by adjustable gastric band (AGB; n = 46) and sleeve gastrectomy (SG; n = 43). Time to cancer diagnosis after bariatric surgery was 9.5 ± 7.4 years, and mean weight at diagnosis was 87.4 ± 21.9 kg. The time lag was 5.9 ± 4.1 years after SG compared to 9.4 ± 7.1 years after RYGB and 10.5 ± 5.7 years after AGB. One third of patients presented with metastatic disease. The majority of tumors were adenocarcinoma (82.9%). Approximately 1 in 5 patients underwent palliative treatment from the outset. Time from diagnosis to mortality was under 1 year for most patients who died over the intervening period. Conclusion: The Oesophago-Gastric Malignancies After Obesity/Bariatric Surgery study presents the largest series to date of patients developing EG malignancies after bariatric surgery and attempts to characterize this condition.info:eu-repo/semantics/publishedVersio

    Nouvelle approche pour la mesure précise de faibles tensions continues

    No full text
    In order to eliminate the errors which usually occur in amplifiers, the authors propose a circuit in which they are automatically compensated. A sampling technique is used, with two phases. During the first one, the error is measured and memorized and during the second, it is substracted from the result of measurement. An application using integrated circuits only is presented.En vue d'éliminer les erreurs que l'on rencontre habituellement dans les amplificateurs, les auteurs proposent un montage permettant de les compenser automatiquement. On emploie une méthode d'échantillonnage comportant deux phases : dans la première, l'erreur est mesurée et mise en mémoire ; dans la deuxième, elle est retranchée du résultat de la mesure. Une réalisation utilisant uniquement des circuits intégrés est présentée

    Nouvelle approche pour la mesure précise de faibles tensions continues

    No full text
    En vue d'éliminer les erreurs que l'on rencontre habituellement dans les amplificateurs, les auteurs proposent un montage permettant de les compenser automatiquement. On emploie une méthode d'échantillonnage comportant deux phases : dans la première, l'erreur est mesurée et mise en mémoire ; dans la deuxième, elle est retranchée du résultat de la mesure. Une réalisation utilisant uniquement des circuits intégrés est présentée

    Mesure simultanée du pouvoir thermoélectrique et de la diffusivité thermique par la méthode de l'impulsion thermique

    No full text
    La méthode de l'impulsion thermique, obtenue par flash optique ou par laser, pour la mesure des caractéristiques thermiques des corps (diffusivité, conductibilité, chaleur spécifique) est bien connue. Nous avons étendu la méthode à la mesure simultanée du pouvoir thermoélectrique. Connaissant l'énergie absorbée par la face antérieure de l'échantillon, l'évolution en température de la face opposée et la f.é.m. résultante obtenue entre les deux faces, on détermine le pouvoir thermoélectrique sans passer par la mesure du gradient de température à travers l'échantillon

    Mesure simultanée du pouvoir thermoélectrique et de la diffusivité thermique par la méthode de l'impulsion thermique

    No full text
    The thermal pulse method, using an optical flash or a laser, for measuring the thermal characteristics of materials (diffusivity, conductivity, specific heat) is well known. We have extended the method to the simultaneous measurement of thermoelectric power. Knowing the energy absorbed by the front surface of the sample, the variation of the temperature of the opposite surface and the resultant emf obtained between the two faces, one determines the thermoelectric power without necessity of measurement of the temperature gradient across the sample.La méthode de l'impulsion thermique, obtenue par flash optique ou par laser, pour la mesure des caractéristiques thermiques des corps (diffusivité, conductibilité, chaleur spécifique) est bien connue. Nous avons étendu la méthode à la mesure simultanée du pouvoir thermoélectrique. Connaissant l'énergie absorbée par la face antérieure de l'échantillon, l'évolution en température de la face opposée et la f.é.m. résultante obtenue entre les deux faces, on détermine le pouvoir thermoélectrique sans passer par la mesure du gradient de température à travers l'échantillon

    Impédancemètre automatique 100 Ω−1\mathsf{\Omega{-}1} TΩ\mathsf{\Omega}

    No full text
    This work presents a wholly automated high impedance system working in the frequency range 1 mHz–10 kHz and conceived to measure complex impedances (RpR_{\rm p} //Cp C_{\rm p}) UP to 1012Ω 10^{12}\Omega. Therefore we have built, surrounding a gain phase analyser, a high impedance programmable electrometer working on shunt mode. This apparatus using high resistances and low leakage capacitors, resorts to the high impedance electronics, the components are selected by the way of very high insulating Reed switches drived by a VXI bus.Dans ce travail nous présentons un système haute impédance totalement automatique fonctionnant dans la gamme de fréquence 1 mHz–10 kHz et conçu pour la mesure des impédances complexes (RpR_{\rm p} //Cp C_{\rm p}) jusqu'à 1012Ω^{12}\Omega. Pour cela nous avons construit, autour d'un analyseur vectoriel, un électromètre haute impédance programmable fonctionnant en mode shunt. Ce dispositif utilisant des résistances de hautes valeurs et des condensateurs à faibles fuites, fait appel à l'électronique haute impédance ; les composants sont sélectionnés au moyen de relais Reed de très haute isolation commandés par un bus VXI

    Comparison between a magneto-optical method and Fannin's technique for measuring Brown's relaxation frequency of ferrofluids

    No full text
    International audienc

    Dielectric study of primary amines from room temperature down to −180 °C and from 10 kHz up to 35 GHz

    No full text
    The aim of this paper is to present the NH2 dielectric behaviour in the primary amines for the importance it bears in the interaction of aminoacids and proteins and their influence in the electric conduction processes. For that, the dielectric properties of 1-propylamine, 1-butylamine and 1-pentylamine have been studied. Measurements were performed between room temperature and −180 °C in the low frequency range and micro-waves measurements were done between −40 °C and 25 °C. The isofrequency recordings of dispersion ε′ and absorption ε′′, for these three primary amines, show clearly the relaxations and the effect of the aliphatic chain length
    corecore