    Effect of early Ambroxol treatment on lung functions in mechanically ventilated preterm newborns who subsequently developed a bronchopulmonary dysplasia (BPD)

    Get PDF
    AbstractIn a randomized trial in 102 preterm newborns with respiratory distress syndrome (RDS) it has been shown that early Ambroxol treatment (30 mg kg−1over the first 5 days) significantly reduces the incidence of RDS-associated complications [bronchopulmonary dysplasia (BPD), intraventricular haemorrhage, post-natal acquired pneumonia]. The aim of the present analysis was to investigate the effect of Ambroxol treatment on lung function in newborns who developed BPD.Respiratory function testing (RFT) was performed immediately after extubation and at day 28. Tidal volume (VT) and respiratory frequency (f) were measured during tidal breathing using the deadspace free flow-through technique. The lung mechanic parameter VT/maxPeswas determined by measuring the maximal oesophageal pressure changes, maxPes, with a catheter tip pressure transducer.In the placebo group 36/50 infants were extubated within the first 28 days of life and 13/36 (36%) developed BPD. In the Ambroxol group 44/52 were extubated and 9/44 (20%) developed BPD. After extubation, RFT showed (i) no statistically significant difference in the ventilatory parameters of either treatment group, (ii) improved (P<0·05) lung mechanics (VT/maxPes) in Ambroxol group compared to controls (9·4±2·7 ml kPa−1vs. 8·1±2·6 ml kPa−1) and (iii) no statistically significant difference in lung function between infants with and without BPD. At day 28 we found (i) no effect of early Ambroxol treatment on lung functions, (ii) significantly (P<0·05) higher f (58·5±11·7 min−1vs. 49·7±10·1 min−1) and significantly (P<0·01) lower VT(9·6±1·9 ml vs. 12·3±2·7 ml) and VT/maxPes(8·9±2·6 ml kPa−1vs. 12·0±2·9 ml kPa−1) in infants with BPD compared to infants without and (iii) these differences are not influenced by early Ambroxol treatment.If the process of BPD development is induced, early Ambroxol treatment has no influence on impaired lung function at day 28

    Differences in tidal breathing between infants with chronic lung diseases and healthy controls

    Get PDF
    BACKGROUND: The diagnostic value of tidal breathing (TB) measurements in infants is controversially discussed. The aim of this study was to investigate to what extent the breathing pattern of sleeping infants with chronic lung diseases (CLD) differ from healthy controls with the same postconceptional age and to assess the predictive value of TB parameters. METHODS: In the age of 36–42 postconceptional weeks TB measurements were performed in 48 healthy newborns (median age and weight 7d, 3100 g) and 48 infants with CLD (80d, 2465 g)) using the deadspace-free flow-through technique. Once the infants had adapted to the mask and were sleeping quietly and breathing regularly, 20–60 breathing cycles were evaluated. Beside the shape of the tidal breathing flow-volume loop (TBFVL) 18 TB parameters were analyzed using ANOVA with Bonferroni correction. Receiver-operator characteristic (ROC) curves were calculated to investigate the discriminative ability of TB parameters. RESULTS: The incidence of concave expiratory limbs in CLD infants was 31% and significantly higher compared to controls (2%) (p < 0.001). Significant differences between CLD infants and controls were found in 11/18 TB parameters. The largest differences were seen in the mean (SD) inspiratory time 0.45(0.11)s vs. 0.65(0.14)s (p < 0.0001) and respiratory rate (RR) 55.4(14.2)/min vs. 39.2(8.6)/min (p < 0.0001) without statistically significant difference in the discriminative power between both time parameters. Most flow parameters were strongly correlated with RR so that there is no additional diagnostic value. No significant differences were found in the tidal volume and commonly used TB parameters describing the expiratory flow profile. CONCLUSION: The breathing pattern of CLD infants differs significantly from that of healthy controls. Concave TBFVL and an increased RR measured during quiet sleep and under standardized conditions may indicate diminished respiratory functions in CLD infants whereas most of the commonly used TB parameters are poorly predictive

    Early Lung Function Testing in Infants with Aortic Arch Anomalies Identifies Patients at Risk for Airway Obstruction

    Get PDF
    BACKGROUND: Aortic arch anomalies (AAA) are rare cardio-vascular anomalies. Right-sided and double-sided aortic arch anomalies (RAAA, DAAA) are distinguished, both may cause airway obstructions. We studied the degree of airway obstruction in infants with AAA by neonatal lung function testing (LFT). PATIENTS AND METHODS: 17 patients (10 RAAA and 7 DAAA) with prenatal diagnosis of AAA were investigated. The median (range) post conception age at LFT was 40.3 (36.6-44.1) weeks, median body weight 3400 (2320-4665) g. Measurements included tidal breathing flow-volume loops (TBFVL), airway resistance (R(aw)) by bodyplethysmography and the maximal expiratory flow at functional residual capacity (V'(max)FRC) by rapid thoracic-abdominal compression (RTC) technique. V'(max)FRC was also expressed in Z-scores, based on published gender-, age and height-specific reference values. RESULTS: Abnormal lung function tests were seen in both RAAA and DAAA infants. Compared to RAAA infants, infants with DAAA had significantly more expiratory flow limitations in the TBFVL, (86% vs. 30%, p<0.05) and a significantly increased R(aw) (p = 0.015). Despite a significant correlation between R(aw) and the Z-score of V'(max)FRC (r = 0.740, p<0.001), there were no statistically significant differences in V'(max)FRC and it's Z-scores between RAAA and DAAA infants. 4 (24%) infants (2 RAAA, 2 DAAA) were near or below the 10(th) percentile of V'(max)FRC, indicating a high risk for airway obstruction. CONCLUSION: Both, infants with RAAA and DAAA, are at risk for airway obstruction and early LFT helps to identify and to monitor these infants. This may support the decision for therapeutic interventions before clinical symptoms arise

    Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Very low birth weight (VLBW) infants (< 1,500 g) with bronchopulmonary dysplasia (BPD) develop lung damage caused by mechanical ventilation and maturational arrest. We compared functional lung development after discharge from hospital between VLBW infants with and without BPD.</p> <p>Methods</p> <p>Comprehensive lung function assessment was performed at about 50, 70, and 100 weeks of postmenstrual age in 55 sedated VLBW infants (29 with former BPD [O<sub>2 </sub>supplementation was given at 36 weeks of gestational age] and 26 VLBW infants without BPD [controls]). Mean gestational age (26 vs. 29 weeks), birth weight (815 g vs. 1,125 g), and the proportion of infants requiring mechanical ventilation for ≥7 d (55% vs. 8%), differed significantly between BPD infants and controls.</p> <p>Results</p> <p>Both body weight and length, determined over time, were persistently lower in former BPD infants compared to controls, but no significant between-group differences were noted in respiratory rate, respiratory or airway resistance, functional residual capacity as determined by body plethysmography (FRC<sub>pleth</sub>), maximal expiratory flow at the FRC (V'max <sub>FRC</sub>), or blood gas (pO<sub>2</sub>, pCO<sub>2</sub>) levels. Tidal volume, minute ventilation, respiratory compliance, and FRC determined by SF6 multiple breath washout (representing the lung volume in actual communication with the airways) were significantly lower in former BPD infants compared to controls. However, these differences became non-significant after normalization to body weight.</p> <p>Conclusions</p> <p>Although somatic growth and the development of some lung functional parameters lag in former BPD infants, the lung function of such infants appears to develop in line with that of non-BPD infants when a body weight correction is applied. Longitudinal lung function testing of preterm infants after discharge from hospital may help to identify former BPD infants at risk of incomplete recovery of respiratory function; such infants are at risk of later respiratory problems.</p

    A Systematic Approach to Multiple Breath Nitrogen Washout Test Quality

    Get PDF
    Background: Accurate estimates of multiple breath washout (MBW) outcomes require correct operation of the device, appropriate distraction of the subject to ensure they breathe in a manner representative of their relaxed tidal breathing pattern, and appropriate interpretation of the acquired data. Based on available recommendations for an acceptable MBW test, we aimed to develop a protocol to systematically evaluate MBW measurements based on these criteria. Methods: 50MBWtest occasions were systematically reviewed for technical elements and whether the breathing pattern was representative of relaxed tidal breathing by an experienced MBW operator. The impact of qualitative and quantitative criteria on inter-observer agreement was assessed across eight MBW operators (n = 20 test occasions, compared using a Kappa statistic). Results: Using qualitative criteria, 46/168 trials were rejected: 16.6%were technically unacceptable and 10.7% were excluded due to inappropriate breathing pattern. Reviewer agreement was good using qualitative criteria and further improved with quantitative criteria from (κ = 0.53– 0.83%) to (κ 0.73–0.97%), but at the cost of exclusion of further test occasions in this retrospective data analysis. Conclusions: The application of the systematic review improved inter-observer agreement but did not affect reported MBW outcomes

    A survey of transcutaneous blood gas monitoring among European neonatal intensive care units

    Get PDF
    BACKGROUND: PCO(2 )and PO(2 )are important monitoring parameters in neonatal intensive care units (NICU). Compared to conventional blood gas measurements that cause significant blood loss in preterms, transcutaneous (tc) measurements allow continuous, non-invasive monitoring of blood gas levels. The aim of the study was to survey the usage and opinions among German speaking NICUs concerning tc blood gas monitoring. METHODS: A questionnaire was developed and sent to 56 head nurses of different NICUs in Germany, Switzerland and Austria. RESULTS: A completely answered questionnaire was obtained from 41 NICUs. In two of these units tc measurements are not performed. In most NICUs (77%), both P(tc)O(2 )and P(tc)CO(2 )are measured simultaneously. Most units change the sensors every 3 hours; however, the recommended temperature of 44°C is used in only 15% of units. In only 8% of units are arterial blood gases obtained to validate tc values. Large variations were found concerning the targeted level of oxygen saturation [median upper limit: 95% (range 80–100%); median lower limit: 86% (range 75–93%)] and PO(2 )[median upper limit: 70 mmHg (range 45–90 mmHg); median lower limit: 44 mmHg (range 30–60 mmHg)]. CONCLUSION: Our survey shows that the use of tc monitors remains widespread among German speaking NICUs, despite earlier data suggesting that their use had been abandoned in many NICUs worldwide. In addition, we suggest that the current method of monitoring oxygenation may not prevent hyperoxemia in preterm infants

    Lung Volume, Breathing Pattern and Ventilation Inhomogeneity in Preterm and Term Infants

    Get PDF
    BACKGROUND: Morphological changes in preterm infants with bronchopulmonary dysplasia (BPD) have functional consequences on lung volume, ventilation inhomogeneity and respiratory mechanics. Although some studies have shown lower lung volumes and increased ventilation inhomogeneity in BPD infants, conflicting results exist possibly due to differences in sedation and measurement techniques. METHODOLOGY/PRINCIPAL FINDINGS: We studied 127 infants with BPD, 58 preterm infants without BPD and 239 healthy term-born infants, at a matched post-conceptional age of 44 weeks during quiet natural sleep according to ATS/ERS standards. Lung function parameters measured were functional residual capacity (FRC) and ventilation inhomogeneity by multiple breath washout as well as tidal breathing parameters. Preterm infants with BPD had only marginally lower FRC (21.4 mL/kg) than preterm infants without BPD (23.4 mL/kg) and term-born infants (22.6 mL/kg), though there was no trend with disease severity. They also showed higher respiratory rates and lower ratios of time to peak expiratory flow and expiratory time (t(PTEF)/t(E)) than healthy preterm and term controls. These changes were related to disease severity. No differences were found for ventilation inhomogeneity. CONCLUSIONS: Our results suggest that preterm infants with BPD have a high capacity to maintain functional lung volume during natural sleep. The alterations in breathing pattern with disease severity may reflect presence of adaptive mechanisms to cope with the disease process

    Persistently Elevated Right Ventricular Index of Myocardial Performance in Preterm Infants with Incipient Bronchopulmonary Dysplasia

    Get PDF
    OBJECTIVES: Elevated pulmonary vascular resistance occurs during the first days after birth in all newborn infants and persists in infants at risk for bronchopulmonary dysplasia (BPD). It is difficult to measure in a non-invasive fashion. We assessed the usefulness of the right ventricular index of myocardial performance (RIMP) to estimate pulmonary vascular resistance in very low birth weight infants. STUDY DESIGN: Prospective echocardiography on day of life (DOL) 2, 7, 14, and 28 in 121 preterm infants (median [quartiles] gestational age 28 [26]-[29] weeks, birth weight 998 [743-1225] g) of whom 36 developed BPD (oxygen supplementation at 36 postmenstrual weeks). RESULTS: RIMP derived by conventional pulsed Doppler technique was unrelated to heart rate or mean blood pressure. RIMP on DOL 2 was similar in infants who subsequently did (0.39 [0.33-0.55]) and did not develop BPD (0.39 [0.28-0.51], p = 0.467). RIMP declined steadily in non-BPD infants but not in BPD infants (DOL 7: 0.31[0.22-0.39] vs. 0.35[0.29-0.48], p = 0.014; DOL 14: 0.23[0.17-0.30] vs. 0.35[0.25-0.43], p<0.001; DOL 28: 0.21[0.15-0.28] vs. 0.31 [0.21-0.35], p = 0.015). CONCLUSIONS: In preterm infants, a decline in RIMP after birth was not observed in those with incipient BPD. The pattern of RIMP measured in preterm infants is commensurate with that of pulmonary vascular resistance

    A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System

    Get PDF
    Background For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N2)MBW system. Methods The N2MBW setup indirectly measures the N2 fraction (FN2) from main-stream carbon dioxide (CO2) and side-stream oxygen (O2) signals: FN2 = 1−FO2−FCO2−FArgon. For in vitro N2MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and FCO2. In vivo N2MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N2MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference]2) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (Sacin and Scond). Results The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. Conclusion The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N2MBW system reliably measures lung volumes and delivers reproducible LCI values