270 research outputs found
On the possibility to utilize a PCO Edge 4.2 bi scientific CMOS imager for extended ultra violet and soft X-ray photon detection
A state of the art commercial detector, a PCO Edge 4.2 bi based on a back illuminated sCMOS sensor developed for applications in the visible light/ultra violet regime has been adapted for ultra-high vacuum operations and has been characterized using soft X-ray in the energy range from 30 eV to 1000 eV. The imager features 2048 x 2048 pixel with a pixel size of 6.5 mu m x 6.5 mu m and allows full frame acquisitions at 48 Hz with a dynamic range of 88 dB at a noise level of 1.9 e(-). Spatial resolution and quantum efficiency have been elucidated in the aforementioned energy range at a soft X-ray beam line at Elettra Sincrotrone Trieste. The handiness of the camera as well as its Python library package allows easy and fast integration into the beam line environments of synchrotron sources and free electron lasers
Fast, multi-band photon detectors based on quantum well devices for beam-monitoring in new generation light sources
In order to monitor the photon-beam position for both diagnostics and calibration purposes, we have investigated the possibility to use InGaAs/InAlAs
Quantum Well (QW) devices as position-sensitive photon detectors for Free-Electron Laser (FEL) or Synchrotron Radiation (SR).
Owing to their direct, low-energy band gap and high electron mobility, such QW devices may be used also at Room Temperature (RT) as fast multi-band sensors for photons ranging from visible light to hard X-rays. Moreover, internal charge-amplification mechanism can be applied for very low signal levels, while the high carrier mobility allows the design of very fast photon detectors with sub-nanosecond response times. Segmented QW sensors have been preliminary tested with 100-fs-wide 400 nm laser pulses and X-ray SR. The reported results indicate that these devices respond with 100 ps rise-times to such ultra-fast laser pulses. Besides, linear scan on the back-pixelated device has shown that these detectors are sensitive to the position of each ultrashort beam bunch
A New Expression for the Gain-Noise Relation of Single-Carrier Avalanche Photodiodes With Arbitrary Staircase Multiplication Regions
We propose a simple expression to relate the total excess noise factor of a single-carrier multiplication staircase avalanche photodiode (APD) to the excess noise factor and gain given by the individual conduction band discontinuities. The formula is valid when electron impact ionization dominates hole impact ionization; hence, it is especially suited for staircase APDs with In-rich multiplication regions, as opposed, for example, to GaAs/AlGaAs systems where hole ionization plays an important role. The formula has been verified by accurate means of numerical simulations based on a newly developed nonlocal history dependent impact ionization model
Optimization of GaAs/AlGaAs staircase avalanche photodiodes accounting for both electron and hole impact ionization
A recently developed nonlocal history dependent model for electron and hole impact ionization is used to compute the gain and the excess noise factor in avalanche photodiodes featuring heterojunctions of III-V compound semiconductors while accounting for both carriers. The model has been calibrated with measurements by our group, as well as on noise versus gain data from the literature. We explore the avalanche photodiode design trade-offs related to the number of GaAs/AlGaAs conduction band steps for X-ray spectroscopy applications
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption
spectroscopy and X-ray diffraction to provide chemically specific structural
information of materials. It operates in the energy range 2.4-27 keV by using a
silicon double reflection Bragg monochromator. The fluorescence measurement is
performed in place of the absorption spectroscopy when the sample transparency
is too low for transmission measurements or the element to study is too diluted
in the sample. We report on the development and on the preliminary tests of a
new prototype detector based on Silicon Drift Detectors technology and the
SIRIO ultra low noise front-end ASIC. The new system will be able to reduce
drastically the time needed to perform fluorescence measurements, while keeping
a short dead time and maintaining an adequate energy resolution to perform
spectroscopy. The custom-made silicon sensor and the electronics are designed
specifically for the beamline requirements.Comment: Proceeding of the 6YRM 12th-14th Oct 2015 - L'Aquila (Italy).
Accepted for publication on Journal of Physics: Conference Serie
Experimental and simulation analysis of carrier lifetimes in GaAs/AlGaAs Avalanche Photo-Diodes
Extensive experimental characterization and TCAD simulation analysis have been used to study the dark current in Avalanche Photo-Diodes (APDs). The comparison between the temperature dependence of measurements and simulations points out that SRH generation/recombination is responsible for the observed dark current. After the extraction of the carrier lifetimes in the GaAs layers, they have been used to predict the APD collection efficiency of the photo-generated currents under realistic operation conditions and as a function of the photogeneration position inside the absorption layer
Analysis of intracellular magnesium and mineral depositions during osteogenic commitment of 3d cultured saos2 cells
In this study, we explore the behaviour of intracellular magnesium during bone phenotype modulation in a 3D cell model built to mimic osteogenesis. In addition, we measured the amount of magnesium in the mineral depositions generated during osteogenic induction. A two-fold increase of intracellular magnesium content was found, both at three and seven days from the induction of differentiation. By X-ray microscopy, we characterized the morphology and chemical composition of the mineral depositions secreted by 3D cultured differentiated cells finding a marked co-localization of Mg with P at seven days of differentiation. This is the first experimental evidence on the presence of Mg in the mineral depositions generated during biomineralization, suggesting that Mg incorporation occurs during the bone forming process. In conclusion, this study on the one hand attests to an evident involvement of Mg in the process of cell differentiation, and, on the other hand, indicates that its multifaceted role needs further investigation
Modeling Approaches for Gain, Noise and Time Response of Avalanche Photodiodes for X-Rays Detection
We report on a suite of modeling approaches for the optimization of Avalanche Photodiodes for X-rays detection. Gain and excess noise are computed efficiently using a non-local/history dependent model that has been validated against full-band Monte Carlo simulations. The (stochastic) response of the detector to photon pulses is computed using an improved Random-Path-Length algorithm. As case studies, we consider diodes consisting of AlGaAs/GaAs multi-layers with separated absorption and multiplication regions. A superlattice creating a staircase conduction band structure is employed in the multiplication region to keep the multiplication noise low. Gain and excess noise have been measured in devices fabricated with such structure and successfully compared with the developed models
High contrast microstructural visualisation of natural acellular matrices by means of phase-based x-ray tomography
Acellular scaffolds obtained via decellularization are a key instrument in regenerative medicine both per se and to drive the development of future-generation synthetic scaffolds that could become available off-the-shelf. In this framework, imaging is key to the understanding of the scaffolds’ internal structure as well as their interaction with ells and other organs, including ideally post-implantation. Scaffolds of a wide range of intricate organs (oesophagus, lung, liver and small intestine) were imaged with x-ray phase contrast computed tomography (PC-CT). Image quality was sufficiently high to visualize scaffold micro architecture and to detect major anatomical features, such as the oesophageal mucosal-submucosal separation, pulmonary alveoli and intestinal villi. These results are a long-sought step for the field of regenerative medicine: until now, histology and scanning electron microscopy have been the gold standard to study the scaffold structure. However, they are both destructive: hence, they are not suitable for imaging scaffolds prior to transplantation, and have no prospect for post-transplantation use. PC-CT, on the other hand, is non-destructive, 3D and fully quantitative. Importantly, not only do we demonstrate achievement of high image quality at two different synchrotron facilities, but also with commercially available x-ray equipment, which makes the method instantly available worldwide to any research laboratory
- …