411 research outputs found

    Internal Transitions of Two-Dimensional Charged Magneto-Excitons X-: Theory and Experiment

    Full text link
    Internal spin-singlet and spin-triplet transitions of charged excitons X- in magnetic fields in quantum wells have been studied experimentally and theoretically. The allowed X- transitions are photoionizing and exhibit a characteristic double-peak structure, which reflects the rich structure of the magnetoexciton continua in higher Landau levels (LL's). We discuss a novel exact selection rule, a hidden manifestation of translational invariance, that governs transitions of charged mobile complexes in a magnetic field.Comment: 4 pages, 2 figures, submitted to Physica

    Integrated Hepatitis C Care for People Who Inject Drugs (Heplink): Protocol for a Feasibility Study in Primary Care (Preprint)

    Get PDF
    Background: Hepatitis C virus (HCV) infection is a major cause of chronic liver disease and death. Drug use remains the significant cause of new infections in the European Union, with estimates of HCV antibody prevalence among people who inject drugs ranging from 5% to 90% in 29 European countries. In Ireland and the European Union, primary care is a key area to focus efforts to enhance HCV diagnosis and treatment among people who inject drugs. Objective: The Heplink study aims to improve HCV care outcomes among opiate substitution therapy (OST) patients in general practice by developing an integrated model of HCV care and evaluating its feasibility, acceptability, and likely efficacy. Methods: The integrated model of care comprises education of community practitioners, outreach of an HCV-trained nurse into general practitioner (GP) practices, and enhanced access of patients to community-based evaluation of their HCV disease (including a novel approach to diagnosis, that is, Echosens FibroScan Mini 430). A total of 24 OST-prescribing GP practices were recruited from the professional networks and databases of members of the research consortium. Patients were eligible if they are aged ≥18 years, on OST, and attend the practice for any reason during the recruitment period. Baseline data on HCV care processes and outcomes were extracted from the clinical records of participating patients. Results: This study is ongoing and has the potential to make an important impact on patient care and provide high-quality evidence to help GPs make important decisions on HCV testing and onward referral. Conclusions: A substantial proportion of HCV-positive patients on OST in general practice are not engaged with specialist hospital services but qualify for direct-acting antiviral drugs treatment. The Heplink model has the potential to reduce HCV-related morbidity and mortality. Registered Report Identifier: RR1-10.2196/904

    Terahertz dynamics of a topologically protected state: quantum Hall effect plateaus near cyclotron resonance in a GaAs/AlGaAs heterojunction

    Full text link
    We measure the Hall conductivity of a two-dimensional electron gas formed at a GaAs/AlGaAs heterojunction in the terahertz regime close to the cyclotron resonance frequency by employing a highly sensitive Faraday rotation method coupled with electrical gating of the sample to change the electron density. We observe clear plateau-and step-like features in the Faraday rotation angle vs. electron density and magnetic field (Landau-level filling factor), which are the high frequency manifestation of quantum Hall plateaus - a signature of topologically protected edge states. The results are compared to a recent dynamical scaling theory.Comment: 18 pages, 3 figure

    Terahertz Magneto Optical Polarization Modulation Spectroscopy

    Full text link
    We report the development of new terahertz techniques for rapidly measuring the complex Faraday angle in systems with broken time-reversal symmetry using the cyclotron resonance of a GaAs two-dimensional electron gas in a magnetic field as a system for demonstration of performance. We have made polarization modulation, high sensitivity (< 1 mrad) narrow band rotation measurements with a CW optically pumped molecular gas laser, and by combining the distinct advantages of terahertz (THz) time domain spectroscopy and polarization modulation techniques, we have demonstrated rapid broadband rotation measurements to < 5 mrad precision.Comment: 25 pages including 7 figures, introduces use of rotating polarizer with THz TDS for Complex Faraday Angle determinatio

    Robust Magnetic Polarons in Type-II (Zn,Mn)Te Quantum Dots

    Full text link
    We present evidence of magnetic ordering in type-II (Zn, Mn) Te quantum dots. This ordering is attributed to the formation of bound magnetic polarons caused by the exchange interaction between the strongly localized holes and Mn within the dots. In our photoluminescence studies, the magnetic polarons are detected at temperatures up to ~ 200 K, with a binding energy of ~ 40 meV. In addition, these dots display an unusually small Zeeman shift with applied field (2 meV at 10 T). This behavior is explained by a small and weakly temperature-dependent magnetic susceptibility due to anti-ferromagnetic coupling of the Mn spins

    Bilateral Assessment of Functional Tasks for Robot-assisted Therapy Applications

    Get PDF
    This article presents a novel evaluation system along with methods to evaluate bilateral coordination of arm function on activities of daily living tasks before and after robot-assisted therapy. An affordable bilateral assessment system (BiAS) consisting of two mini-passive measuring units modeled as three degree of freedom robots is described. The process for evaluating functional tasks using the BiAS is presented and we demonstrate its ability to measure wrist kinematic trajectories. Three metrics, phase difference, movement overlap, and task completion time, are used to evaluate the BiAS system on a bilateral symmetric (bi-drink) and a bilateral asymmetric (bi-pour) functional task. Wrist position and velocity trajectories are evaluated using these metrics to provide insight into temporal and spatial bilateral deficits after stroke. The BiAS system quantified movements of the wrists during functional tasks and detected differences in impaired and unimpaired arm movements. Case studies showed that stroke patients compared to healthy subjects move slower and are less likely to use their arm simultaneously even when the functional task requires simultaneous movement. After robot-assisted therapy, interlimb coordination spatial deficits moved toward normal coordination on functional tasks

    Identification of a prognostic signature in colorectal cancer using combinatorial algorithm-driven analysis

    Get PDF
    Acknowledgements The colorectal cancer microarray was provided by the NHS Grampian Biorepository and the majority of the immunostaining was performed in the Grampian Biorepository laboratory (www.biorepository.nhsgrampian.org/). The antibodies were developed in collaboration with Vertebrate Antibodies Ltd (https://vertebrateantibodies.com/)Peer reviewedPublisher PD

    HEPCARE EUROPE- A Case study of a Service Innovation Project Aiming at Improving the Elimination of HCV in Vulnerable Populations in Four European Cities

    Get PDF
    OBJECTIVES: Hepatitis C Virus (HCV) is an important cause of chronic liver disease. Among at-risk populations, access to diagnosis and treatment is challenging. We describe an integrated model of care, Hepcare Europe, developed to address this challenge. METHODS: Using a case-study approach, we describe the cascade of care outcomes at all sites. Costing analyses estimated the cost per person screened and linked to care. RESULTS: A total of 2608 participants were recruited across 218 clinical sites. HCV antibody test results were obtained for 2568(98.5%), 1074(41.8%) were antibody-positive, 687(60.5%) tested positive for HCV-RNA, 650(60.5%) were linked to care and 319(43.5%) started treatment. 196(61.4%) of treatment initiates achieved a Sustained Viral Response (SVR) at dataset closure, 108(33.9%) were still on treatment, 8(2.7%) defaulted from treatment, and 7(2.6%) had a virologic failure or died. The cost per person screened varied from Є194 to Є635, while cost per person linked to care varied from Є364 to Є2035. CONCLUSIONS: Hepcare enhanced access to HCV treatment and cure, costs were affordable in all settings, offering a framework for scale-up and reproducibility

    Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    Get PDF
    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components

    Internal transitions of quasi-2D charged magneto-excitons in the presence of purposely introduced weak lateral potential energy variations

    Full text link
    Optically detected resonance spectroscopy has been used to investigate effects of weak random lateral potential energy fluctuations on internal transitions of charged magneto-excitons (trions) in quasi two-dimensional GaAs/AlGaAs quantum-well (QW) structures. Resonant changes in the ensemble photoluminescence induced by far-infrared radiation were studied as a function of magnetic field for samples having: 1) no growth interrupts (short range well-width fluctuations), and 2) intentional growth interrupts (long range monolayer well-width differences). Only bound-to-continuum internal transitions of the negatively charged trion are observed for samples of type 1. In contrast, a feature on the high field (low energy) side of electron cyclotron resonance is seen for samples of type 2 with well widths of 14.1 and 8.4 nm. This feature is attributed to a bound-to-bound transition of the spin-triplet with non-zero oscillator strength resulting from breaking of translational symmetry.Comment: 16 pages, 3 figures, submitted to Physical Review
    corecore