224 research outputs found

    Decoupling of a Neutron Interferometer from Temperature Gradients

    Get PDF
    Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation which relaxes these stringent isolation requirements. Here, the INDEX Collaboration and National Institute of Standards and Technology demonstrates the functionality of a neutron interferometer in vacuum and characterize the use of a compact vacuum chamber enclosure as a means to isolate the interferometer from spatial temperature gradients and time-dependent temperature fluctuations. The vacuum chamber is found to have no depreciable effect on the performance of the interferometer (contrast) while improving system stability, thereby showing that it is feasible to replace large temperature isolation and control systems with a compact vacuum enclosure for perfect crystal neutron interferometry

    Neutron interferometer crystallographic imperfections and gravitationally induced quantum interference measurements

    Get PDF
    © 2017 American Physical Society, https://dx.doi.org/10.1103/physreva.95.013840Dynamical diffraction leads to an interesting, unavoidable set of interference effects for neutron interferometers. This experiment studies the interference signal from two and three successive Bragg diffractions in the Laue geometry. We find that intrinsic Bragg-planemisalignment in monolithic, "perfect" silicon neutron interferometers is relevant between successive diffracting crystals, as well as within the Borrmann fan for typical interferometer geometries. We show that the dynamical phase correction employed in the Colella, Overhauser, and Werner gravitationally induced quantum interference experiments is attenuated by slight, intrinsic misalignments between diffracting crystals, potentially explaining the long-standing 1% discrepancy between theory and experiment. This systematic may also impact precision measurements of the silicon structure factor, affecting previous and future measurements of the Debye-Waller factor and neutron-electron scattering length as well as potential fifth-force searches. For the interferometers used in this experiment, Bragg planes of different diffracting crystals were found to be misaligned by 10 to 40 nrad.U.S. Department of Energy: DE-FG02-97ER41042National Science Foundation: PHY-1307426, PHY-1205342Canada Excellence Research Chairs, Government of Canada: 215284Natural Sciences and Engineering Research Council of Canada: RGPIN-41857

    Measurement of Receptor-Activated Phosphoinositide Turnover in Rat Brain: Nonequivalence of Inositol Phosphate and CDP-Diacylglycerol Formation

    Full text link
    Two methods for the measurement of receptor-activated phosphoinositide turnover were evaluated for their degree of correspondence in slices of rat brain; they involved the Li + -dependent accumulations of either [ 3 H]-inositol-labeled inositol phosphates or [ 3 H]cytidine-labeled CDP-diacylglycerol. In contrast to the expectation that the ratio of these two responses would remain approximately constant, varying degrees of correspondence were obtained. The two extremes are exemplified by carbachol, which elicited large increases in both inositol phosphate and CDP-diacylglycerol labeling, and endothelin, which gave a robust inositol phosphate response with little or no accumulation of 3 H-CDP-diacylglycerol. No instance of the presence of the latter response in the absence of 3 H-inositol phosphate accumulation was observed. Measurement of 3 H-CDP-diacylglycerol accumulation thus may add additional insight into the regulation of phosphoinositide turnover and the complex actions of Li + .Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/66135/1/j.1471-4159.1993.tb03258.x.pd

    Holography with a neutron interferometer

    Get PDF
    © 2016 Optical Society of America. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved.We use a Mach-Zehnder interferometer to perform neutron holography of a spiral phase plate. The object beam passes through a spiral phase plate, acquiring the phase twist characteristic of orbital angular momentum states. The reference beam passes through a fused silica prism, acquiring a linear phase gradient. The resulting hologram is a fork dislocation image, which could be used to reconstruct neutron beams with various orbital angular momenta. This work paves the way for novel applications of neutron holography, diffraction and imaging.Canada Excellence Research Chairs, Government of Canada: 215284National Institute of Standards and TechnologyNatural Sciences and Engineering Research Council of Canada: RGPIN-418579U.S. Department of Energy: DE-FG02-97ER41042National Science Foundation: PHY-1307426, PHY-1205342Collaborative Research and Training Experience (CREATE) program: 41406

    A sensitive search for dark energy through chameleon scalar fields using neutron interferometry

    Get PDF
    The physical origin of the dark energy, which is postulated to cause the accelerated expansion rate of the universe, is one of the major open questions of cosmology. A large subset of theories postulate the existence of a scalar field with a nonlinear coupling to matter chosen so that the effective range and/or strength of the field is greatly suppressed unless the source is placed in vacuum. We describe a measurement using neutron interferometry which can place a stringent upper bound on chameleon fields proposed as a solution to the problem of the origin of dark energy of the universe in the regime with a strongly-nolinear coupling term. In combination with other experiments searching for exotic short-range forces and laser-based measurements, slow neutron experiments are capable of eliminating this and many similar types of scalar-field-based dark energy models by laboratory experiments.NSF grant PHY-1068712Indiana University Center for the Exploration of Energy and MatterIndiana University Center for Spacetime SymmetriesCanadian Excellence Research, NSERC Discovery and CREATE Progra
    corecore