10 research outputs found

    Soliton Solutions on Noncommutative Orbifold $ T^2/Z_4

    Full text link
    In this paper, we explicitly construct a series of projectors on integral noncommutative orbifold T2/Z4T^2/Z_4 by extended GHSGHS constrution. They include integration of two arbitary functions with Z4Z_4 symmetry. Our expressions possess manifest Z4Z_{4} symmetry. It is proved that the expression include all projectors with minimal trace and in their standard expansions, the eigen value functions of coefficient operators are continuous with respect to the arguments kk and qq. Based on the integral expression, we alternately show the derivative expression in terms of the similar kernal to the integral one.Since projectors correspond to soliton solutions of the field theory on the noncommutative orbifold, we thus present a series of corresponding solitons.Comment: 18 pages, no figure; referrences adde

    Comparison of Airway Intubation Devices When Using a Biohazard Suit: A Feasibility Study

    Get PDF
    OBJECTIVES: We set out to compare emergency medicine residents\u27 intubating times and success rates for direct laryngoscopy (DL), GlideScope-assisted intubation (GS), and the Supraglottic Airway Laryngopharyngeal Tube (SALT) airway with and without biohazard gear. METHODS: Each resident passed through 2 sets of 3 testing stations (DL, GS, SALT) in succession, intubating Laerdal mannequin heads with the 3 modalities after randomization to start with or without biohazard gear. RESULTS: Thirty-seven residents participated, and 27 were male (73%); 14 (37.8%) had prior experience intubating in biohazard suits. There was a statistically significant difference in those who had prior intubation experience between DL (37, 100%), GS (32, 86.5%), and SALT (12, 32.4%) (P \u3c .001) and in median time to intubation (48 seconds, no suit; 57 seconds, with suits) (P = .03). There was no statistically significant difference between the overall times to intubate for the 3 devices. First-pass success was highest for DL (91.2%, no suit; 83.7%, suit) followed by GS (89%, no suit; 78.3%, suit) and SALT (51%, no suit; 67.6%, suit). CONCLUSION: A minority of participants had prior experience intubating in biohazard suits. Use of biohazard suits extends time to successful intubation. There was no difference in time to intubation for the 3 devices, but first-pass success was highest for DL (with or without biohazard gear)

    Extremism and Social Learning

    Full text link

    Comparison of Airway Intubation Devices When Using a Biohazard Suit: a Feasibility Study.

    No full text
    OBJECTIVES: We set out to compare emergency medicine residents\u27 intubating times and success rates for direct laryngoscopy (DL), GlideScope-assisted intubation (GS), and the Supraglottic Airway Laryngopharyngeal Tube (SALT) airway with and without biohazard gear. METHODS: Each resident passed through 2 sets of 3 testing stations (DL, GS, SALT) in succession, intubating Laerdal mannequin heads with the 3 modalities after randomization to start with or without biohazard gear. RESULTS: Thirty-seven residents participated, and 27 were male (73%); 14 (37.8%) had prior experience intubating in biohazard suits. There was a statistically significant difference in those who had prior intubation experience between DL (37, 100%), GS (32, 86.5%), and SALT (12, 32.4%) (P \u3c .001) and in median time to intubation (48 seconds, no suit; 57 seconds, with suits) (P = .03). There was no statistically significant difference between the overall times to intubate for the 3 devices. First-pass success was highest for DL (91.2%, no suit; 83.7%, suit) followed by GS (89%, no suit; 78.3%, suit) and SALT (51%, no suit; 67.6%, suit). CONCLUSION: A minority of participants had prior experience intubating in biohazard suits. Use of biohazard suits extends time to successful intubation. There was no difference in time to intubation for the 3 devices, but first-pass success was highest for DL (with or without biohazard gear)
    corecore