1,079 research outputs found

    A novel technology for disinfecting surfaces infested with Candida auris: the UVC chip

    Get PDF
    Background The fungal pathogen Candida Auris is increasingly associated with multidrug-resistant infections that are highly expensive for the Health Care System. The spreading of this pathogen can occur, among others, through contact with infected surfaces or medical instruments. This study evaluated the efficacy of a novel UVC chip, novel alternative to UVC LEDs and lamps, in inactivating Candida auris strain. Methods This experimental study was carried out between July and September 2020 at the University of Siena. Candida auris (ATCC 12372) at two known concentrations (1.5X107 and 1.5x106 CFU/ml) at a fixed distance (7,5 cm) from the chip (5.1mW radiant power) was tested, in triplicates, with three exposure times (5, 10 and 15 minutes). Potato Dextrose Agar (PDA) plates without the plate lid and containing Candida auris were exposed to UVC light. Subsequently, the plates were incubated at 36 °C for 48 h. Log reduction between treated and positive control (not exposed to UVC light) samples was calculated. Results At 15 minutes, we had the highest inactivation result, mean 4.43 log10, starting from a 1.5x106 CFU/mL concentration. At a higher concentration, 1.5X107 CFU/mL, the reduction had a mean of 3.51 log10. Conclusions The results of the experiments showed a significant microbial reduction in relation to the exposure time. The highest level of reduction was reached after 15 minutes of exposure. UVC chip had a relevant biocidal effect on Candida auris and may represent a valuable tool in the prevention of infections caused by this pathogen, which is becoming increasingly prevalent and persistent globally. Key messages • The use of UVC Chip decreases surface contamination. • New technology against healthcare-associated infections

    A time-varying SIRD model for dynamic vaccination strategies against COVID-19

    Get PDF
    The COVID-19 pandemic has demonstrated how the optimal allocation of the limited doses of vaccine available represents one of the main useful measures to mitigate the transmission of the infection and reduce the mortality associated with it, especially at an early stage of the pandemic. The use of a compartmental model allows us to understand which population groups to vaccinate and to what extent to act depending on the type of health or social objective to be achieved

    Wind of change: Better air for microbial environmental control

    Get PDF
    Background: The COVID19 epidemic highlighted the importance of air in the transmission of pathogens. Air disinfection is one of the key points to reduce the risk of transmission both in the health sector and in public, civil and industrial environments. All bacteria and viruses tested to date can be inactivated by UV-C rays. Laboratory tested UV-C systems are increasingly popular and proposed as effective technologies for air purification; few studies have evaluated their performance in populated indoor environments. The aim of this investigation was to evaluate the effectiveness of a UV-C disinfection system for air in a real working context. Methods: This experimental study was conducted between December 2020 and February 2021 in an office of the Department of Molecular and Developmental Medicine of the University of Siena, Italy. A pre-final version air purifier (Cleaning Air T12), capable of treating 210 m3/h of air, was first tested for its ability to filter particulates and reduce microbial air contamination in the absence of people. Subsequently, the experiments were conducted in the presence of 3–5 subjects who worked for several hours in an office. During the tests, microbiological samples of air were collected in real time, switching the system on and off periodically. Air samples were collected and incubated on Petri dishes at 36 ◦C and 22 ◦C. Statistical analysis was performed with Stata 16 software assuming a significance level of 95%. An interpolating model was identified to describe the dynamics of contamination reduction when the device operates. Results: Preliminary tests showed a significant 62.5% reduction in Colony-Forming Units (CFUs) with 36 ◦C incubation. Reductions in the particulate component were also observed. In the main test, comparison of CFU data, between the device-on phase (90 min) and the subsequent device-off phase (60 min), showed statistically significant increase (p = 0.001) of environmental contamination passing from a mean of 86.6 (65.8–107.4) to 171.1 (143.9–198.3) CFU/m3, that is a rise of about 100%. The interpolating model exhibited a good fit of CFU reduction trend with the device on. Conclusions: The system, which mainly uses UV-C lamps for disinfection, was able to significantly reduce envi- ronmental and human contamination in real time. Experimental tests have shown that as soon as the device is switched off, after at least half an hour of operation, the healthiness of the air decreases drastically within 10 minutes, bringing the airborne microbial contamination (induced by the presence of operators in the environ- ment) to levels even higher than 150% of the last value with the device on. Re-engineering strategies for system improvement were also discusse

    Safer school with near-UV technology: novel applications for environmental hygiene

    Get PDF
    Systems capable of disinfecting air and surfaces could reduce the risk of infectious diseases transmission. Aim: to evalu-ate the effectiveness of near-UV LED ceiling lamps, with a wavelength of 405 nm, in improving environmental hygiene. Between November and December 2020, we conducted an experimental study having a pre-post design in a kindergarten room in Siena where 4 ceiling lamps with 405 nm LED technology were installed. Twice per day, sampling was performed before (T0) and after treatment with near-UV (T1). We used between 8 and 12 pairs of contact plates to sample at various random spots each day. Air samplings were also performed. The plates were incubated at 22 and 36 degrees C. Significance was set at 95% (p < 0.05). The mean level of Colony Forming Unit (CFU) at T(0) was 249 (95% CI 193.1 - 305.0) at 36 degrees C and 535.2 (374.3 - 696.1) at 22 degrees C. The reduction was significant at T(1): by 65% at 36 degrees C and, 72% at 22 degrees C. Also, for air contamination: 95.3% (98.4 & mdash;92.3). A dose threshold of about 5 J/cm2 was identified to have an 80% CFU abatement and remains nearly constant. The advantage of being able to use this technology in the presence of people is very important in the context of controlling environmental contamination. © 2023, The Author(s)

    concordance and time estimation of store and forward mobile teledermatology compared to classical face to face consultation

    Get PDF
    Smartphones have overcome the limitations of image quality seen in older devices and opened a new field of telemedicine called "mobile teledermatology". Technological advances and the need to reduce health service costs will strongly promote the development of telemedicine. For this reason, we evaluated the concordance be tween store-and-forward mobile teledermatology and the classical face-to-face dermatological visit. We also measured the time taken to submit a teleconsultation using a smartphone. Before conventional face-to-face visit, a final-year resident of the 3-year course for general practitioners collected medical history, took digital images of skin diseases with a smartphone and, measuring the time required to complete this operation, transmitted them to an expert teledermatologist. In 391 patients we obtained a concordance between face-to-face and store-and-forward diagnosis of 91.05% (Cohen κ coefficient = 0.906). On average only few minutes needs to be added to a no

    An Updated Algorithm Integrated With Patient Data for the Differentiation of Atypical Nevi From Early Melanomas: the idScore 2021

    Get PDF
    Introduction: It is well known that multiple patient-related risk factors contribute to the development of cutaneous melanoma, including demographic, phenotypic and anamnestic factors. Objectives: We aimed to investigate which MM risk factors were relevant to be incorporated in a risk scoring-classifier based clinico-dermoscopic algorithm. Methods: This retrospective study was performed on a monocentric dataset of 374 atypical melanocytic skin lesions sharing equivocal dermoscopic features, excised in the suspicion of malignancy. Dermoscopic standardized images of 258 atypical nevi (aN) and 116 early melanomas (eMM) were collected along with objective lesional data (i.e., maximum diameter, specific body site and body area) and 7 dermoscopic data. All cases were combined with a series of 10 MM risk factors, including demographic (2), phenotypic (5) and anamnestic (3) ones. Results: The proposed iDScore 2021 algorithm is composed by 9 variables (age, skin phototype I/II, personal/familiar history of MM, maximum diameter, location on the lower extremities (thighs/legs/ ankles/back of the feet) and 4 dermoscopic features (irregular dots and globules, irregular streaks, blue gray peppering, blue white veil). The algorithm assigned to each lesion a score from 0 to 18, reached an area under the ROC curve of 92% and, with a score threshold ≥ 6, a sensitivity (SE) of 98.2% and a specificity (SP) of 50.4%, surpassing the experts in SE (+13%) and SP (+9%).Conclusions: An integrated checklist combining multiple anamnestic data with selected relevant dermoscopic features can be useful in the differential diagnosis and management of eMM and aN exhibiting with equivocal features

    Antenatal syphilis serology in pregnant women and follow-up of their infants in northern Italy

    Get PDF
    ABSTRACTPositive syphilis serology was noted in 119 (0.49%) of the 24 053 pregnant women delivering at St Orsola Hospital in Bologna, Italy, from November 2000 through July 2007. Six presumptive cases of congenital syphilis with IgM western blot positive results were found. Two infants had a positive cerebrospinal fluid (CSF) Venereal Disease Research Laboratory test result (one also had a positive CSF PCR result), another presented long-bone lesions, and the remaining three were preterm. These observations confirmed that antenatal syphilis screening facilitates treatment during pregnancy and offsets vertical transmission; moreover, the use of IgM western blot and careful CSF examination allowed the identification and treatment of high-risk newborns

    Italy-Japan agreement and discrepancies in diagnosis of superficial gastric lesions.

    Get PDF
    The agreement between Italian and Japanese endoscopists and pathologists on endoscopic and histopathological diagnoses of superficial gastric lesions is verified with the use of Paris and Vienna classifications. The correlations between Paris endoscopic types and Vienna histopathological categories is high in both the independent Italian and Japanese evaluations. However, the agreement between Italian and Japanese endoscopists is moderate due to the difficult evaluation of the height of the lesions, in particular when they are mixed. The agreement on the size of the lesions is fairly good. The probability of the same allocation to the Vienna categories of a single case is 87 per cent, disagreements remaining in dysplasia grading, between dysplasia, not only high-grade but also low-grade, and in situ carcinoma, and on cancer invasion of the lamina propria. The results indicate that use of the Paris and Vienna classifications has reduced the discrepancies between Western and Japanese endoscopists and pathologists in the diagnosis of these lesions
    • …
    corecore