10 research outputs found

    Perioperative time course of matrix metalloproteinase-9 (MMP-9), its tissue inhibitor TIMP-1 & S100B protein in carotid surgery

    No full text
    Background & objectives: Ischaemic stroke is a life burdening disease for which carotid endarterectomy (CEA) is considered a gold standard intervention. Pro-inflammatory markers like matrix metalloproteinases (MMPs) and their inhibitors (TIMPs) and S-100 Beta (S100B) may have a role in the early inflammation and cognitive decline following CEA. This study was aimed to describe the perioperative time courses and correlations between of MMP-9, TIMP-1 and S100B following CEA. Methods: Fifty four patients scheduled for CEA were enrolled. Blood samples were collected at four time points, T 1 : preoperative, T 2 : 60 min after cross-clamp release, T 3 : first postoperative morning, T 4 : third postoperative morning. Twenty atherosclerotic patients were included as controls. Plasma MMP-9, TIMP-1 and S100B levels were estimated by ELISA. Results: TIMP-1 was decreased significantly in the CEA group (P<0.01). Plasma MMP-9 was elevated and remained elevated from T 1-4 in the CEA group (P<0.05) with a marked elevation in T 3 compared to T 1 (P<0.05). MMP-9/TIMP-1 was elevated in the CEA group and increased further by T 2 and T 3 (P<0.05). S100B was elevated on T 2 and decreased on T 3-4 compared to T 1 . Interpretation & conclusions: Our study provides information on the dynamic changes of MMP-9-TIMP-1 system and S100B in the perioperative period. Preoperative reduction of TIMP-1 might be predictive for shunt requirement but future studies are required for verification

    Comparison of the perioperative time courses of matrix metalloproteinase-9 (MMP-9) and its inhibitor (TIMP-1) during carotid artery stenting (CAS) and carotid endarterectomy (CEA)

    No full text
    Abstract Background Our aim was to compare the perioperative time courses of matrix metalloproteinase-9 (MMP-9) and its inhibitor (TIMP-1) in during carotid endarterectomy (CEA) and carotid artery stenting (CAS). Methods In our prospective study, twenty-five patients who were scheduled to undergo CAS were enrolled. We used a matched, historical CEA group as controls. Blood samples were collected at four time points: T1: preoperative; T2: 60 min after stent insertion; T3: first postoperative morning; and T4: third postoperative morning. Plasma MMP-9 and TIMP-1 levels were measured by ELISA. Results In the CEA group, the plasma levels of MMP-9 were significantly elevated at T3 compared to T1. In the CAS group, there was no significant difference in MMP-9 levels in the perioperative period. MMP-9 levels were significantly higher in the T3 samples of the CEA group compared to the CAS group. Significantly lower TIMP-1 levels were measured in both groups at T2 than at T1 in both groups. MMP-9/TIMP-1 at T3 was significantly higher than that at T1 in the CEA group compared to both T1 and the CAS group. Conclusions CAS triggers smaller changes in the MMP-9-TIMP-1 system during the perioperative period, which may correlate with a lower incidence of central nervous system complications. Additional studies as well as cognitive and functional surveys are warranted to determine the clinical relevance of our findings. Trial registration NIH U.S. National Library of Medicine, Clinicaltrials.gov,NCT03410576, 24.01.2018, Retrospectively registere

    Comparison of VividTrac®, Airtraq®, King Vision®, Macintosh Laryngoscope and a Custom-Made Videolaryngoscope for difficult and normal airways in mannequins by novices

    No full text
    Abstract Background Direct laryngoscopy remains the gold standard for endotracheal intubation and is preferred by experienced operators. However, an increasing number of reports currently support videolaryngoscopy, particularly for novice users. The widespread use of videolaryngoscopy may be limited due to financial limitations, especially in low-income countries. Therefore, affordable single-use scopes are now becoming increasingly popular. We sought to compare these new scopes with direct laryngoscopes and the previously tested videolaryngoscopes in mannequins by novices. Methods Fifty medical students were recruited to serve as novice users. Following brief, standardized training, students were asked to execute endotracheal intubation with each of the devices, including the Airtraq®, a custom-made videolaryngoscope, the King Vision®, the Macintosh laryngoscope and the VividTrac®, on an airway trainer (Laerdal Airway Management Trainer®) in normal and difficult airway scenarios. We evaluated the time to and the proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction. Results We observed no differences in esophageal intubation. However, intubation-related times, the view of the glottis and operator satisfaction were significantly better throughout the study with the commercial videolaryngoscopes. In comparison, the custom-made videolaryngoscope performance proved to be similar to that of the Macintosh laryngoscope. The VividTrac® performance was similar (P > 0.05) or significantly better than that of the King Vision® in both scenarios. Conclusions Based upon our results, the Airtraq®, King Vision® and VividTrac® were superior to the Macintosh laryngscope in both normal and difficult airway scencarios for novice users. In particular, our study is the first to report that the VividTrac® shows promise for further clinical evaluation

    Intracranial volume inversely correlates with serum 25(OH)D level in healthy young women

    No full text
    Objectives Vitamin D is important in normal brain development. In animals low vitamin D level is associated with brain morphological alterations including enlargement of the brain. Whether a similar association exists in humans is unknown. Here we investigated the relationship between vitamin D and total intracranial volume as well as total volume of the cortical grey and cerebral white matter and that of the ventricles in young healthy women. Methods To assess volumes we applied semi-automatic user-independent MR volumetry. For the vitamin D measurements automated electrochemiluminescence immunoassay was used. Results We found a significant negative correlation between vitamin D and total intracranial volume as well as total cortical grey and cerebral white matter volumes. Discussion This association may reflect a trait-like relationship between vitamin D and brain size possibly determined in early development

    Comparison and evaluation of seven different bench-top flow cytometers with a modified six-plexed mycotoxin kit.

    No full text
    Many bench-top flow cytometers (b-FCs) are compatible with microsphere-based multiplexed assays. Disciplines implementing b-FCs-based assays are expanding; they include monitoring and validating food quality. A multiplexed platform protocol was evaluated for poly-mycotoxin assays, which is compatible with a variety of b-FC models. The seven instruments included: BD FACSCalibur, BD FACSArray Bioanalyzer, Accuri C6, Partec CyFlow(R) Space, Beckman Coulter FC 500, Guava EasyCyte Mini, and Luminex 100 . Current reports related to the food industry describe fungal co-infections leading to poly-mycotoxin contamination in grain (Sulyok M, Berthiller F, Krska R, Schuhmacher R, Rapid Commun Mass Spectrom 2006;20:2649-2659). It is imperative to determine whether b-FC-based assays can replace traditional single-mycotoxin enzyme-linked immunosorbent assay (ELISA). A six-plexed poly-mycotoxin kit was tested on seven different b-FCs. The modified kit was initially developed for the BD FACSArray Bioanalyzer (BD Biosciences) (Czeh A, Mandy F, Feher-Toth S, Torok L, Mike Z, Koszegi B, Lustyik G, J Immunol Methods 2012;384:71-80). With the multiplexed platform, it is possible to identify up to six mycotoxin contaminants simultaneously at regional grain collection/transfer/inspection facilities. In the future, elimination of contaminated food threat may be better achieved with the inclusion of b-FCs in the food protection arsenal. A universal protocol, matched with postacquisition software, offers an effective alternative platform compared to using a series of ELISA kits. To support side-by-side evaluation of seven flow cytometers, an instrument-independent fluorescence emission calibration was added to the protocol. All instrument performances were evaluated for strength of agreement based on paired sets of evaluation to predicate method. The results suggest that all b-FCs were acceptable of performing with the multiplexed kit for five of six mycotoxins. For OTA, the detection sensitivity was consistent only for five of the seven instruments. (c) 2013 International Society for Advancement of Cytometry
    corecore