    Treatment of simple bone cyst with bone marrow concentrate and equine-derived demineralized bone matrix injection versus methylprednisolone acetate injections: A retrospective comparative study

    Get PDF
    Objective: The aim of this study was to compare the outcome of intra-lesional autologous bone marrow concentrate (BMC) and equine derived demineralized bone matrix (EDDBM) injections with methylprednisolone acetate injections in patients with simple bone cyst. Methods: Clinical records and radiographs of 53 consecutive patients (37 females, and 16 males; mean age: 10.61 +/- 1.53 years) treated between 2006 and 2016 were retrospectively reviewed. Healing was assessed by an independent radiologist according to Neer scoring system. Functional outcome was assessed with the Activity Scale for Kids (ASK). Thirty-four cysts were in the humerus, 13 in the femur and 6 in other locations. Twenty-nine patients were included in Steroid Group and treated with 3 cycles of injections of methylprednisolone acetate, while 24 patients were treated with injection of autologous bone marrow concentrate and equine derived demineralized bone matrix (BMC + EDDBM Group). The two groups were homogenous for the mean age, sex distribution, cysts location and their clinical presentation. Results: At a minimum follow-up of 24 months, success rate (Neer/Cole score 3 and 4) was higher in EDDBM+BMC group (83.3% vs 58.6%; p=0.047). Female patients had higher healing rates in both groups (p=0.002). No association was found between healing and age (p=0.839), cyst activity (p=0.599), cyst localization (p=0.099) and clinical presentation (p=0.207). BMC+EDDBM group showed higher ASK score (p=0.0007). Conclusion: Treatment with BMC+EDDBM injections may provide better results with a single procedure than 3 methylprednisolone acetate injections and represent an interesting alternative for the treatment of unicameral bone cysts

    Polyvinylpyridine-supported palladium nanoparticles: An efficient catalyst for Suzuki–Miyaura coupling reactions

    Get PDF
    Palladium nanoparticles (Pd NPs) synthesized by the metal vapor synthesis technique were supported on poly(4-vinylpyridine) 2% cross-linked with divinylbenzene (Pd/PVPy). Transmission electron microscopy revealed the presence of small metal nanoparticles (dm = 2.9 nm) highly dispersed on the PVPy. The Pd/PVPy system showed high catalytic efficiency in Suzuki-Miyaura carbon–carbon coupling reactions of both non-activated and deactivated aromatic iodides and bromides with aryl boronic acids, carried out under an air atmosphere. The high turnover of the catalyst and the ability of the PVPy resin to retain active Pd species are highlighted. By comparing the catalytic performances of Pd/PVPy with those observed by using commercially available Pd-based supported catalysts, the reported system showed higher selectivity and lower Pd leaching

    Total Synthesis of Asparenydiol by Two Sonogashira Cross-Coupling Reactions Promoted by Supported Pd and Cu Catalysts

    Get PDF
    Asparenydiol, which is an important natural compound with potential pharmacological activities, was synthesized through two Sonogashira cross-coupling reactions catalyzed by supported Pd and Cu catalysts and by a Mitsunobu etherification. The optimization of the Sonogashira couplings allowed the use of catalysts supported on different matrices with good results in terms of catalytic efficiency and yields

    Usefulness of multimodality imaging approach in the diagnosis of mechanical prosthetic valve dysfunction

    Get PDF
    Background Although the long-term outcome of mechanical mitral and aortic prosthetic valve (M-PV, Ao-PV), PV dysfunction (PVD) remains a very serious complication associated with high morbidity and mortality. Thrombosis/pannus and paravalvular leak are the 2 main mechanisms of PVD. The diagnosis of PVD, based on clinical presentation may be challenging, but it is essential for referring the patient to the optimal treatment (clinical follow-up, thrombolysis, surgery). An integrated multimodality imaging approach, comprising several parameters by transthoracic echocardiography (TTE) and fluoroscopy (F), is mandatory to pursue the correct therapeutic pathway. Purpose This study aims to evaluate the incremental diagnostic value of combined TTE+F over each imaging modality alone in symptomatic pts with Ao-PV or M-PV and high suspicion of PVD. Methods 387 consecutive pts (63\ub111y, 213 Ao-PV, 173 M-PV) suspected for PVD, symptomatic for dyspnea, embolic events, fever or haemolysis were enrolled. All patients were imaged by TTE and F within 2 days after the admission to the hospital. TTE was defined positive for PVD in presence of intra/para-prosthetic regurgitation or high transprosthetic gradient (>20mmHg in Ao-PV, >8mmHg in M-PV) together with altered Doppler parameters (for Ao-PV: DVI <0.25, AT>95ms; for M-PV: Peak Mitral Velocity>2m/sec, VTIPrMV/VTILVO>2.5, PHT>130ms). F was defined positive for PVD when leaflet/s restriction occurs. PVD was confirmed by transoesophageal echocardiography (TOE) or positive response of thrombolysis (T), or surgical inspection (S). Results PVD was found in 46% (99/213) of Ao-PV and in 53% (91/173) of M-PV at TOE/T/S. Sensitivity (SE), specificity (SP), negative predictive value (NPV), positive predictive value (PPV) and diagnostic accuracy (ACC) for TTE, F and combined TTE+F are reported in Table. The integration of TTE+F data significantly improved ACC both for Ao-PV and M-PV. At ROC analysis, the combined model of TTE+F showed the highest AUC for the detection of PVD compared with TTE and F alone (Figure). Table 1. Comparison of diagnostic accuracy between TTE, F, and TTE+F TTE-Ao-PV (n=211) F-Ao_PV (n=204) TTE+F-Ao-PV (n=202) TTE-M-PV (n=172) F-M-PV (n=158) TTE+F-M-PV (n=157) SE / SP / NPV / PPV / ACC (%) 86 / 89 / 88 / 88 / 88 59 / 99 / 72 / 98 / 79 94 / 88 / 94 / 88 / 91 74 / 90 / 75 / 89 / 81 49 / 96 / 60 / 93 / 70 81 / 86 / 78 / 88 / 83 Figure 1. ROC curves Conclusions In patients with clinical suspicion of PVD, TTE and F are both valid tools to evaluate the PV performance. However, the combined model of TTE+F had a significant incremental value over TTE or F alone to diagnose the presence of PVD. This multimodality imaging approach allows to overcome several weaknesses of the TTE or F alone and consequently provides a prompt recognition of PVD even though TOE remains the gold standard to diagnose paravalvular Leak and non-obstructive thrombosis

    Do rebreathing manoeuvres for non-invasive measurement of cardiac output during maximum exercise test alter the main cardiopulmonary parameters?

    Get PDF
    Background: Inert gas rebreathing has been recently described as an emergent reliable non-invasive method for cardiac output determination during exercise, allowing a relevant improvement of cardiopulmonary exercise test clinical relevance. For cardiac output measurements by inert gas rebreathing, specific respiratory manoeuvres are needed which might affect pivotal cardiopulmonary exercise test parameters, such as exercise tolerance, oxygen uptake and ventilation vs carbon dioxide output (VE/VCO2) relationship slope. Method: We retrospectively analysed cardiopulmonary exercise testing of 181 heart failure patients who underwent both cardiopulmonary exercise testing and cardiopulmonary exercise test+cardiac output within two months (average 16 \ub1 15 days). All patients were in stable clinical conditions (New York Heart Association I\u2013III) and on optimal medical therapy. Results: The majority of patients were in New York Heart Association Class I and II (78.8%), with a mean left ventricular ejection fraction of 31 \ub1 10%. No difference was found between the two tests in oxygen uptake at peak exercise (1101 (interquartile range 870\u20131418) ml/min at cardiopulmonary exercise test vs 1103 (844\u20131389) at cardiopulmonary exercise test-cardiac output) and at anaerobic threshold. However, anaerobic threshold and peak heart rate, peak workload (75 (58\u2013101) watts and 64 (42\u201390), p < 0.01) and carbon dioxide output were significantly higher at cardiopulmonary exercise testing than at cardiopulmonary exercise test+cardiac output, whereas VE/VCO2 slope was higher at cardiopulmonary exercise test+cardiac output (30 (27\u201335) vs 33 (28\u201337), p < 0.01). Conclusion: The similar anaerobic threshold and peak oxygen uptake in the two tests with a lower peak workload and higher VE/VCO2 slope at cardiopulmonary exercise test+cardiac output suggest a higher respiratory work and consequent demand for respiratory muscle blood flow secondary to the ventilatory manoeuvres. Accordingly, VE/VCO2 slope and peak workload must be evaluated with caution during cardiopulmonary exercise test+cardiac output

    Endothelial Dysfunction in Patients with Severe Mitral Regurgitation

    Get PDF
    Mitral valve prolapse (MVP) is the most common cause of severe mitral regurgitation. It has been reported that MVP patients-candidates for mitral valve repair (MVRep)-showed an alteration in the antioxidant defense systems as well as in the L-arginine metabolic pathway. In this study, we investigate if oxidative stress and endothelial dysfunction are an MVP consequence or driving factors. Forty-five patients undergoing MVRep were evaluated before and 6 months post surgery and compared to 29 controls. Oxidized (GSSG) and reduced (GSH) forms of glutathione, and L-arginine metabolic pathway were analyzed using liquid chromatography-tandem mass spectrometry methods while osteoprotegerin (OPG) through the ELISA kit and circulating endothelial microparticles (EMP) by flow cytometry. Six-month post surgery, in MVP patients, the GSSG/GSH ratio decreased while symmetric and asymmetric dimethylarginines levels remained comparable to the baseline. Conversely, OPG levels significantly increased when compared to their baseline. Finally, pre-MVRep EMP levels were significantly higher in patients than in controls and did not change post surgery. Overall, these results highlight that MVRep completely restores the increased oxidative stress levels, as evidenced in MVP patients. Conversely, no amelioration of endothelial dysfunction was evidenced after surgery. Thus, therapies aimed to restore a proper endothelial function before and after surgical repair could benefit MVP patients
    • …