769 research outputs found

    Thermal Analysis of Polyamide-66/POSS nanocomposite fiber

    Full text link
    Poly Hexamethylene Adipamide (PA-66) nanocomposite fibers were prepared by melt mixing PA-66 using two Polyhedral Oligomeric Silsesquioxane (POSS) as fillers: Octaphenyl Polyhedral Oligomeric Silsesquioxane (OPS) and Octa-Aminophenyl Polyhedral Oligomeric Silsesquioxane (OAPS). OPS and OAPS in PA-66 was varied between 1% wt. and 3% wt. PA-66 nanocomposite fibers with varying concentrations of POSS were then analyzed using TGA, DSC and then compared to that of neat PA-66. PA-66 was thermally stable up to 350°C with low molecular weight species burning off below 200°C. PA-66-OPS were also thermally stable up to 350°C with burn-off of low molecular weight species being below 240°C. PA-66-OAPS was found to be more thermally stable (up to 400°C) with low molecular weight species burning off below 200°C. The decomposition temperatures of the PA66/POSS nanocomposites increased as the POSS content was increased, an indicator that the thermal decay of the PA66/POSS nanocomposites was slowed down by incorporating POSS into the PA66 matrix. Addition of POSS to PA-66 also increased crystallization temperature but did not change the melting temperatures. OAPS exhibited better thermal behavior when added to PA-66 compared to OPS and therefore is recommended as a prospective nanomaterial for further studies

    Panel Discussion On Lipid Metabolism In Cardiovascular Disease†

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/111126/1/jgs00741.pd

    High prevalence of <i>Rickettsia africae</i> variants in <i>Amblyomma variegatum</i> ticks from domestic mammals in rural western Kenya: implications for human health

    Get PDF
    Tick-borne spotted fever group (SFG) rickettsioses are emerging human diseases caused by obligate intracellular Gram-negative bacteria of the genus Rickettsia. Despite being important causes of systemic febrile illnesses in travelers returning from sub-Saharan Africa, little is known about the reservoir hosts of these pathogens. We conducted surveys for rickettsiae in domestic animals and ticks in a rural setting in western Kenya. Of the 100 serum specimens tested from each species of domestic ruminant 43% of goats, 23% of sheep, and 1% of cattle had immunoglobulin G (IgG) antibodies to the SFG rickettsiae. None of these sera were positive for IgG against typhus group rickettsiae. We detected Rickettsia africae–genotype DNA in 92.6% of adult Amblyomma variegatum ticks collected from domestic ruminants, but found no evidence of the pathogen in blood specimens from cattle, goats, or sheep. Sequencing of a subset of 21 rickettsia-positive ticks revealed R. africae variants in 95.2% (20/21) of ticks tested. Our findings show a high prevalence of R. africae variants in A. variegatum ticks in western Kenya, which may represent a low disease risk for humans. This may provide a possible explanation for the lack of African tick-bite fever cases among febrile patients in Kenya

    A Theoretical Model for Gas Separation in a Glow Discharge: Cataphoresis

    Get PDF
    A theoretical model for transient and steady-state cataphoresis is developed starting with the macroscopic equations of continuity. After a brief breakdown period, the impurity ions are assumed to be closely coupled with their neutral counterparts. The basic assumptions in the model are that after breakdown, the level of ionization of the impurity, and the axial electric field remain constant; it is demonstrated that under these conditions a system involving rapid ionization-recombination reactions is equivalent to a system in which no reaction occurs, but in which the effective\u27\u27 ion mobility is a product of the true ion mobility and the fraction of impurity ionization. The influence of endbulbs commonly employed in experiments is analyzed and found to influence greatly the characteristic time required to reach steady state. Agreement is found between the model and available experimental data. Particular emphasis is placed upon mass spectrometer data reported by Matveeva, and by Beckey, Groth, and Welge; these data are for mixtures of rare gases and for mixtures of hydrogen and deuterium, and involve endbulbs. The ordinary diffusion case, associated with the collapse of the steady-state cataphoretic profile, is also analyzed for a system containing endbulbs

    Treatment of Heavy Quarks in Deeply Inelastic Scattering

    Full text link
    We investigate a simplified version of the ACOT prescription for calculating deeply inelastic scattering from Q^2 values near the squared mass M_H^2 of a heavy quark to Q^2 much larger than M_H^2.Comment: 14 pages, 5 figure

    Comparing the EQ-5D-3 L and EQ-5D-5 L:studying measurement and scores in Indonesian type 2 diabetes mellitus patients

    Get PDF
    BACKGROUND: The EuroQoL five-dimensional instrument (EQ-5D) is the favoured preference-based instrument to measure health-related quality of life (HRQoL) in several countries. Two versions of the EQ-5D are available: the 3-level version (EQ-5D-3 L) and the 5-level version (EQ-5D-5 L). This study aims to compare specific measurement properties and scoring of the EQ-5D-3 L (3 L) and EQ-5D-5 L (5 L) in Indonesian type 2 diabetes mellitus (T2DM) outpatients.METHODS: A survey was conducted in a hospital and two primary healthcare centres on Sulawesi Island. Participants were asked to complete the two versions of the EQ-5D instruments. The 3 L and 5 L were compared in terms of distribution and ceiling, discriminative power and test-retest reliability. To determine the consistency of the participants' answers, we checked the redistribution pattern, i.e., the consistency of a participant's scores in both versions.RESULTS: A total of 198 T2DM outpatients (mean age 59.90 ± 11.06) completed the 3 L and 5 L surveys. A total of 46 health states for 3 L and 90 health states for 5 L were reported. The '11121' health state was reported most often: 17% in the 3 L and 13% in the 5 L. The results suggested a lower ceiling effect for 5 L (11%) than for 3 L (15%). Regarding redistribution, only 6.1% of responses were found to be inconsistent in this study. The 5 L had higher discriminative power than the 3 L version. Reliability as reflected by the index score was 0.64 for 3 L and 0.74 for 5 L. Pain/discomfort was the dimension mostly affected, whereas the self-care dimension was the least affected.CONCLUSIONS: This study suggests that the 5 L-version of the EQ-5D instrument performs better than the 3 L-version in T2DM outpatients in Indonesia, regarding measurement and scoring properties. As such, our study supports the use of the 5 L as the preferred health-related quality of life measurement tool. We did not do a trial but this study was approved by the Medical Ethics Committee of Universitas Gadjah Mada Yogyakarta, Indonesia (document number KE/FK/1188/EC, 12 November 2014, amended 16 March 2015).</p

    Comparing the EQ-5D-3 L and EQ-5D-5 L:studying measurement and scores in Indonesian type 2 diabetes mellitus patients

    Get PDF
    BACKGROUND: The EuroQoL five-dimensional instrument (EQ-5D) is the favoured preference-based instrument to measure health-related quality of life (HRQoL) in several countries. Two versions of the EQ-5D are available: the 3-level version (EQ-5D-3 L) and the 5-level version (EQ-5D-5 L). This study aims to compare specific measurement properties and scoring of the EQ-5D-3 L (3 L) and EQ-5D-5 L (5 L) in Indonesian type 2 diabetes mellitus (T2DM) outpatients. METHODS: A survey was conducted in a hospital and two primary healthcare centres on Sulawesi Island. Participants were asked to complete the two versions of the EQ-5D instruments. The 3 L and 5 L were compared in terms of distribution and ceiling, discriminative power and test-retest reliability. To determine the consistency of the participants' answers, we checked the redistribution pattern, i.e., the consistency of a participant's scores in both versions. RESULTS: A total of 198 T2DM outpatients (mean age 59.90 ± 11.06) completed the 3 L and 5 L surveys. A total of 46 health states for 3 L and 90 health states for 5 L were reported. The '11121' health state was reported most often: 17% in the 3 L and 13% in the 5 L. The results suggested a lower ceiling effect for 5 L (11%) than for 3 L (15%). Regarding redistribution, only 6.1% of responses were found to be inconsistent in this study. The 5 L had higher discriminative power than the 3 L version. Reliability as reflected by the index score was 0.64 for 3 L and 0.74 for 5 L. Pain/discomfort was the dimension mostly affected, whereas the self-care dimension was the least affected. CONCLUSIONS: This study suggests that the 5 L-version of the EQ-5D instrument performs better than the 3 L-version in T2DM outpatients in Indonesia, regarding measurement and scoring properties. As such, our study supports the use of the 5 L as the preferred health-related quality of life measurement tool. We did not do a trial but this study was approved by the Medical Ethics Committee of Universitas Gadjah Mada Yogyakarta, Indonesia (document number KE/FK/1188/EC, 12 November 2014, amended 16 March 2015)

    Astrometric Methods and Instrumentation to Identify and Characterize Extrasolar Planets: A Review

    Full text link
    I present a review of astrometric techniques and instrumentation utilized to search for, detect, and characterize extra-solar planets. First, I briefly summarize the properties of the present-day sample of extrasolar planets, in connection with predictions from theoretical models of planet formation and evolution. Next, the generic approach to planet detection with astrometry is described, with significant discussion of a variety of technical, statistical, and astrophysical issues to be faced by future ground-based as well as space-borne efforts in order to achieve the required degree of measurement precision. After a brief summary of past and present efforts to detect planets via milli-arcsecond astrometry, I then discuss the planet-finding capabilities of future astrometric observatories aiming at micro-arcsecond precision. Lastly, I outline a number experiments that can be conducted by means of high-precision astrometry during the next decade, to illustrate its potential for important contributions to planetary science, in comparison with other indirect and direct methods for the detection and characterization of planetary systems.Comment: 61 pages, 8 figures, PASP, accepted (October 2005 issue

    Tests of a large air‐core superconducting solenoid as a nuclear‐reaction‐product spectrometer

    Get PDF
    An air‐core superconducting solenoid, with a diameter of 0.2 m and a length of 0.4 m, has been configured for use as a heavy‐ion reaction‐product spectrometer (E/A≤5 MeV/u) near θ=0° (10 to 35 msr). The performance of the spectrometer was established using α‐particle sources and nuclear‐reaction products from (18O, 18Ne), (18O, 20Ne) and (18O, 14O) and masses determined for 30Mg, 108Ru and 109Rh. A system suitable for production of radioactive beams has been constructed, and in‐beam tests are in progress at the University of Notre Dame. Large air‐core solenoids with dΩ≤20 msr and capable of focusing ions with E/A≥30 MeV/u appear feasible.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87304/2/845_1.pd
    corecore