1,568 research outputs found
Bayesian Error Estimation in Density Functional Theory
We present a practical scheme for performing error estimates for Density
Functional Theory calculations. The approach which is based on ideas from
Bayesian statistics involves creating an ensemble of exchange-correlation
functionals by comparing with an experimental database of binding energies for
molecules and solids. Fluctuations within the ensemble can then be used to
estimate errors relative to experiment on calculated quantities like binding
energies, bond lengths, and vibrational frequencies. It is demonstrated that
the error bars on energy differences may vary by orders of magnitude for
different systems in good agreement with existing experience.Comment: 5 pages, 3 figure
Muscle velocity recovery cycles in myopathy.
OBJECTIVE
To understand the pathophysiology of myopathies by using muscle velocity recovery cycles (MVRC) and frequency ramp (RAMP) methodologies.
METHODS
42 patients with quantitative electromyography (qEMG) and biopsy or genetic verified myopathy and 42 healthy controls were examined with qEMG, MVRC and RAMP, all recorded from the anterior tibial muscle.
RESULTS
There were significant differences in the motor unit potential (MUP) duration, the early and late supernormalities of the MVRC and the RAMP latencies in myopathy patients compared to controls (p < 0.05 apart from muscle relatively refractory period (MRRP)). When dividing into subgroups, the above-mentioned changes in MVRC and RAMP parameters were increased for the patients with non-inflammatory myopathy, while there were no significant changes in the group of patients with inflammatory myopathy.
CONCLUSIONS
The MVRC and RAMP parameters can discriminate between healthy controls and myopathy patients, more significantly for non-inflammatory myopathy. MVRC differences with normal MRRP in myopathy differs from other conditions with membrane depolarisation.
SIGNIFICANCE
MVCR and RAMP may have a potential in understanding disease pathophysiology in myopathies. The pathogenesis in non-inflammatory myopathy does not seem to be caused by a depolarisation of the resting membrane potential but rather by the change in sodium channels of the muscle membrane
Inelastic transport theory from first-principles: methodology and applications for nanoscale devices
We describe a first-principles method for calculating electronic structure,
vibrational modes and frequencies, electron-phonon couplings, and inelastic
electron transport properties of an atomic-scale device bridging two metallic
contacts under nonequilibrium conditions. The method extends the
density-functional codes SIESTA and TranSIESTA that use atomic basis sets. The
inelastic conductance characteristics are calculated using the nonequilibrium
Green's function formalism, and the electron-phonon interaction is addressed
with perturbation theory up to the level of the self-consistent Born
approximation. While these calculations often are computationally demanding, we
show how they can be approximated by a simple and efficient lowest order
expansion. Our method also addresses effects of energy dissipation and local
heating of the junction via detailed calculations of the power flow. We
demonstrate the developed procedures by considering inelastic transport through
atomic gold wires of various lengths, thereby extending the results presented
in [Frederiksen et al., Phys. Rev. Lett. 93, 256601 (2004)]. To illustrate that
the method applies more generally to molecular devices, we also calculate the
inelastic current through different hydrocarbon molecules between gold
electrodes. Both for the wires and the molecules our theory is in quantitative
agreement with experiments, and characterizes the system-specific mode
selectivity and local heating.Comment: 24 pages, 17 figure
Comparison of figure-of-8 and circular coils for threshold tracking transcranial magnetic stimulation measurements
OBJECTIVES: The transcranial magnetic stimulation (TMS) technique of threshold-tracking short-interval intracortical inhibition (T-SICI) has been proposed as a diagnostic tool for amyotrophic lateral sclerosis (ALS). Most of these studies have used a circular coil, whereas a figure-of-8 coil is usually recommended for paired-pulse TMS measurements. The aim of this study was to compare figure-of-8 and circular coils for T-SICI in the upper limb, with special attention to reproducibility, and the pain or discomfort experienced by the subjects. METHODS: Twenty healthy subjects (aged: 45.5 ± 6.7, mean ± SD, 9 females, 11 males) underwent two examinations with each coil, in morning and afternoon sessions on the same day, with T-SICI measured at interstimulus intervals (ISIs) from 1-7 ms. After each examination the subjects rated degree of pain/discomfort from 0 to 10 using a numerical rating scale (NRS). RESULTS: Mean T-SICI was higher for the figure-of-8 than for the circular coil at ISI of 2 ms (p < 0.05) but did not differ at other ISIs. Intra-subject variability did not differ between coils, but mean inhibition from 1-3.5 ms was less variable between subjects with the figure-of-8 coil (SD 7.2% vs. 11.2% RMT, p < 0.05), and no such recordings were without inhibition (vs. 6 with the circular coil). The subjects experienced less pain/discomfort with the figure-of-8 coil (mean NRS: 1.9 ± 1.28 vs 2.8 ± 1.60, p < 0.005). DISCUSSION: The figure-of-8 coil may have better applicability in patients, due to the lower incidence of lack of inhibition in healthy subjects, and the lower experience of pain or discomfort
Placental transfer of the polybrominated diphenyl ethers BDE-47, BDE-99 and BDE-209 in a human placenta perfusion system: an experimental study
<p>Abstract</p> <p>Background</p> <p>Polybrominated diphenyl ethers (PBDEs) have been widely used as flame retardants in consumer products. PBDEs may affect thyroid hormone homeostasis, which can result in irreversible damage of cognitive performance, motor skills and altered behaviour. Thus, in utero exposure is of very high concern due to critical windows in fetal development.</p> <p>Methods</p> <p>A human ex vivo placenta perfusion system was used to study the kinetics and extent of the placental transfer of BDE-47, BDE-99 and BDE-209 during four-hour perfusions. The PBDEs were added to the maternal circulation and monitored in the maternal and fetal compartments. In addition, the perfused cotyledon, the surrounding placental tissue as well as pre-perfusion placental tissue and umbilical cord plasma were also analysed. The PBDE analysis included Soxhlet extraction, clean-up by adsorption chromatography and GC-MS analysis.</p> <p>Results and Discussion</p> <p>Placental transfer of BDE-47 was faster and more extensive than for BDE-99. The fetal-maternal ratios (FM-ratio) after four hours of perfusion were 0.47 and 0.25 for BDE-47 and BDE-99, respectively, while the indicative permeability coefficient (IPC) measured after 60 minutes of perfusion was 0.26 h<sup>-1 </sup>and 0.10 h<sup>-1</sup>, respectively. The transport of BDE-209 seemed to be limited. These differences between the congeners may be related to the degree of bromination. Significant accumulation was observed for all congeners in the perfused cotyledon as well as in the surrounding placental tissue.</p> <p>Conclusion</p> <p>The transport of BDE-47 and BDE-99 indicates in utero exposure to these congeners. Although the transport of BDE-209 was limited, however, possible metabolic debromination may lead to products which are both more toxic and transportable. Our study demonstrates fetal exposure to PBDEs, which should be included in risk assessment of PBDE exposure of women of child-bearing age.</p
Down-regulation of CK2α correlates with decreased expression levels of DNA replication minichromosome maintenance protein complex (MCM) genes
- …