10 research outputs found

    The role of experience in echocardiographic identification of location and extent of mitral valve prolapse with 2D and 3D echocardiography

    Get PDF
    Contradiction exists on the incremental value of two-dimensional (2D) and 3D transoesophageal echocardiography (TOE) over 2D transthoracic echocardiography (TTE) for the detection of mitral valve (MV) prolapse in readers with different echocardiographic experience. Twenty patients and five healthy persons were retrospectively identified who had undergone 2D-TTE, 2D-TOE and 3D-TOE. Fifteen (75 %) patients had surgical evidence of prolapse of the posterior MV leaflet and five patients (25 %) had a dilated MV annulus without prolapse. Three reader groups with different echocardiographic expertise (novice, trainees, cardiologists) scored thus in total 675 posterior scallops. Overall there was an improvement in agreement and Kappa values from novice to trainees to cardiologists. Diagnostic accuracies of 2D-TOE were higher than those of 2D-TTE mainly in novice readers. The incremental value of 3D-TOE over 2D-TOE was mainly seen in specificities. Time to diagnosis was dramatically reduced from 2D to 3D-TEE in all reader groups (all P < 0.001). 3D-TOE also improved the agreement (+12 to +16 %) and Kappa values (+0.14 to +0.21) in all reader groups for the exact description of P2 prolapse. Differences between readers with variable experience in determining the precise localization and extent of the prolapsing posterior MV scallops exist in particular in 2D-TTE analysis. 3D-TOE analysis was extremely fast compared to the 2D analysis methods and showed the best diagnostic accuracy (mainly driven by specificity) with identification of P1 and P3 prolapse still improving from novice to trainees to cardiologists and provided optimal description of P2 prolapse extent

    Interprofessional Consensus Regarding Design Requirements for Liquid-Based Perinatal Life Support (PLS) Technology

    Get PDF
    Liquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design. The aim of this paper is to provide a framework for research and development of PLS technology. These requirements are considering the possible respective user perspectives, with the aim to co-create a PLS system that facilitates physiological growth and development for extremely preterm born infants

    Diffusion-Weighted MRI for Selection of Complete Responders After Chemoradiation for Locally Advanced Rectal Cancer: A Multicenter Study

    Get PDF
    PURPOSE: In 10-24% of patients with rectal cancer who are treated with neoadjuvant chemoradiation, no residual tumor is found after surgery (ypT0). When accurately selected, these complete responders might be considered for less invasive treatments instead of standard surgery. So far, no imaging method has proven reliable. This study was designed to assess the accuracy of diffusion-weighted MRI (DWI) in addition to standard rectal MRI for selection of complete responders after chemoradiation. METHODS: A total of 120 patients with locally advanced rectal cancer from three university hospitals underwent chemoradiation followed by a restaging MRI (1.5T), consisting of standard T2W-MRI and DWI (b0-1000). Three independent readers first scored the standard MRI only for the likelihood of a complete response using a 5-point confidence score, after which the DWI images were added and the scoring was repeated. Histology (ypT0 vs. ypT1-4) was the standard reference. Diagnostic performance for selection of complete responders and interobserver agreement were compared for the two readings. RESULTS: Twenty-five of 120 patients had a complete response (ypT0). Areas under the ROC-curve for the three readers improved from 0.76, 0.68, and 0.58, using only standard MRI, to 0.8, 0.8, and 0.78 after addition of DWI (P = 0.39, 0.02, and 0.002). Sensitivity for selection of complete responders ranged from 0-40% on standard MRI versus 52-64% after addition of DWI. Specificity was equally high (89-98%) for both reading sessions. Interobserver agreement improved from kappa 0.2-0.32 on standard MRI to 0.51-0.55 after addition of DWI. CONCLUSIONS: Addition of DWI to standard rectal MRI improves the selection of complete responders after chemoradiation

    Asymptomatic Patients with Severe Aortic Stenosis and the Impact of Intervention

    No full text
    Objectives the exact timing of aortic valve replacement (AVR) in asymptomatic patients with severe aortic stenosis (AS) remains a matter of debate. Therefore, we described the natural history of asymptomatic patients with severe AS, and the effect of AVR on long-term survival. Methods: Asymptomatic patients who were found to have severe AS between June 2006 and May 2009 were included. Severe aortic stenosis was defined as peak aortic jet velocity Vmax ≥ 4.0 m/s or aortic valve area (AVA) ≤ 1 cm2. Development of symptoms, the incidence of AVR, and all-cause mortality were assessed. Results: A total of 59 asymptomatic patients with severe AS were followed, with a mean follow-up of 8.9 ± 0.4 years. A total of 51 (86.4%) patients developed AS related symptoms, and subsequently 46 patients underwent AVR. The mean 1-year, 2-year, 5-year, and 10-year overall survival rates were higher in patients receiving AVR compared to those who did not undergo AVR during follow-up (100%, 93.5%, 89.1%, and 69.4%, versus 92.3%, 84.6%, 65.8%, and 28.2%, respectively; p &lt; 0.001). Asymptomatic patients with severe AS receiving AVR during follow-up showed an incremental benefit in survival of up to 31.9 months compared to conservatively managed patients (p = 0.002). Conclusions: The majority of asymptomatic patients turn symptomatic during follow-up. AVR during follow-up is associated with better survival in asymptomatic severe AS patients

    Uncertainties and challenges in surgical and transcatheter tricuspid valve therapy : a state-of-the-art expert review

    No full text
    Tricuspid regurgitation (TR) is a frequent and complex problem, commonly combined with left-sided heart disease, such as mitral regurgitation. Significant TR is associated with increased mortality if left untreated or recurrent after therapy. Tricuspid regurgitation was historically often disregarded and remained undertreated. Surgery is currently the only Class I Guideline recommended therapy for TR, in the form of annuloplasty, leaflet repair, or valve replacement. As growing experience of transcatheter therapy in structural heart disease, many dedicated transcatheter tricuspid repair or replacement devices, which mimic well-established surgical techniques, are currently under development. Nevertheless, many aspects of TR are little understood, including the disease process, surgical or interventional risk stratification, and predictors of successful therapy. The optimal treatment timing and the choice of proper surgical or interventional technique for significant TR remain to be elucidated. In this context, we aim to highlight the current evidence, underline major controversial issues in this field and present a future roadmap for TR therapy

    Interprofessional Consensus Regarding Design Requirements for Liquid-Based Perinatal Life Support (PLS) Technology

    No full text
    Liquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design. The aim of this paper is to provide a framework for research and development of PLS technology. These requirements are considering the possible respective user perspectives, with the aim to co-create a PLS system that facilitates physiological growth and development for extremely preterm born infants

    A prospective multi-centre study of the value of FDG-PET as part of a structured diagnostic protocol in patients with fever of unknown origin.

    No full text
    Contains fulltext : 52019.pdf (publisher's version ) (Closed access)PURPOSE: Since (18)F-fluorodeoxyglucose (FDG) accumulates in neoplastic cells and in activated inflammatory cells, positron emission tomography (PET) with FDG could be valuable in diagnosing patients with fever of unknown origin (FUO). The aim of this study was to validate the use of FDG-PET as part of a structured diagnostic protocol in the general patient population with FUO. METHODS: From December 2003 to July 2005, 70 patients with FUO were recruited from one university hospital (n=38) and five community hospitals (n=32). A structured diagnostic protocol including FDG-PET was used. A dedicated, full-ring PET scanner was used for data acquisition. FDG-PET scans were interpreted by two staff members of the department of nuclear medicine without further clinical information. The final clinical diagnosis was used for comparison with the FDG-PET results. RESULTS: Of all scans, 33% were clinically helpful. The contribution of FDG-PET to the final diagnosis did not differ significantly between patients diagnosed in the university hospital and patients diagnosed in the community hospitals. FDG-PET contributed significantly more often to the final diagnosis in patients with continuous fever than in patients with periodic fever. FDG-PET was not helpful in any of the patients with normal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP). CONCLUSION: FDG-PET is a valuable imaging technique as part of a diagnostic protocol in the general patient population with FUO and a raised ESR or CRP

    Selective iNOS inhibition for the treatment of sepsis-induced acute kidney injury.

    No full text
    Contains fulltext : 81592.pdf (publisher's version ) (Closed access)The incidence and mortality of sepsis and the associated development of acute kidney injury (AKI) remain high, despite intense research into potential treatments. Targeting the inflammatory response and/or sepsis-induced alterations in the (micro)circulation are two therapeutic strategies. Another approach could involve modulating the downstream mechanisms that are responsible for organ system dysfunction. Activation of inducible nitric oxide (NO) synthase (iNOS) during sepsis leads to elevated NO levels that influence renal hemodynamics and cause peroxynitrite-related tubular injury through the local generation of reactive nitrogen species. In many organs iNOS is not constitutively expressed; however, it is constitutively expressed in the kidney and, in humans, a relationship between the upregulation of renal iNOS and proximal tubular injury during systemic inflammation has been demonstrated. For these reasons, the selective inhibition of renal iNOS might have important implications for the treatment of sepsis-induced AKI. Various animal studies have demonstrated that selective iNOS inhibition-in contrast to nonselective NOS inhibition-attenuates sepsis-induced renal dysfunction and improves survival, a finding that warrants investigation in clinical trials. In this Review, the selective inhibition of iNOS as a potential novel treatment for sepsis-induced AKI is discussed
    corecore