37 research outputs found

    Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening-filter-free 7 MV beam line.

    No full text
    The aim of our work is to provide the up-to-now missing information on the Siemens Artiste FFF 7 MV beam line using a Monte-Carlo model fit to the realistic dosimetric measurements at the linear accelerator in clinical use at our department. The main Siemens Artiste 6MV and FFF 7MV beams were simulated using the Geant4 toolkit. The simulations were compared with the measurements with an ionization chamber in a water phantom to verify the validation of simulation and tuning the primary electron parameters. Hereafter, other parameters such as surface dose, spectrum, electron contamination, symmetry, flatness/unflatness, slope, and characteristic off-axis changes were discussed for both Flat and FFF mode. The mean electron energy for the FFF beam was 8.8 MeV and 7.5 MeV for Flat 6 MV, the spread energy and spot size of the selected Gaussian distribution source were 0.4 MeV and 1mm, respectively. The dose rate of the FFF beam was 2.8 (2.96) times higher than for the flattened beam for a field size of 10×10 (20×20) cm2. The electron contamination has significant contribution to the surface dose especially for the flattened beam. The penumbra, surface dose and the mean energy of photons decrease by removing the flattening filter. Finally, the results show that off-axis changes have no strong effect on the mean energy of FFF beams, while this effect was more considerable for the flattened beam

    Comparative planning of flattening-filter-free and flat beam IMRT for hypopharynx cancer as a function of beam and segment number.

    No full text
    Although highly conformal dose distributions can be achieved by IMRT planning, this often requires a large number of segments or beams, resulting in increased treatment times. While flattening-filter-free beams offer a higher dose rate, even more segments may be required to create homogeneous target coverage. Therefore, it is worthwhile to systematically investigate the dependence of plan quality on gantry angles and number of segments for flat vs. FFF beams in IMRT planning. For the practical example of hypopharynx cancer, we present a planning study of flat vs. FFF beams using three different configurations of gantry angles and different segment numbers. The two beams are very similar in physical properties, and are hence well-suited for comparative planning. Starting with a set of plans of equal quality for flat and FFF beams, we assess how far the number of segments can be reduced before the plan quality is markedly compromised, and compare monitor units and treatment times for the resulting plans. As long as a sufficiently large number of segments is permitted, all planning scenarios give good results, independently of gantry angles and flat or FFF beams. For smaller numbers of segments, plan quality decreases both for flat and FFF energies; this effect is stronger for fewer gantry angles and for FFF beams. For low segment numbers, FFF plans are generally worse than the corresponding flat beam plans, but they are less sensitive to a decrease in segment number if many gantry angles are used (18 beams); in this case the quality of flat and FFF plans remains comparable even for few segments

    Imaging dose and secondary cancer risk in image-guided radiotherapy of pediatric patients

    No full text
    Abstract Background Daily image-guided radiotherapy (IGRT) can contribute to cover extended body volumes with low radiation dose. The effect of additional imaging dose on secondary cancer development is modelled for a collective of children with Morbus Hodgkin. Methods Eleven radiotherapy treatment plans from pediatric patients with Hodgkin’s lymphoma were retrospectively analyzed, including imaging dose from scenarios using different energies (kV/MV) and planar/cone-beam computed tomography (CBCT) techniques. In addition to assessing the effect of imaging dose on organs at risk, the excess average risk (EAR) for developing a secondary carcinoma of the lung or breast was modelled. Results Although the variability between the patients is relatively large due to the different target volumes, the additional EAR due to imaging can be consistently determined. For daily 6MV CBCT, the EAR for developing a secondary cancer at age 50 is over 3 cases per 104 PY (patient-years) for the female breast and 0.7–0.8 per 104 PY for the lungs. This can be decreased by using only planar images (< 1 per 104 PY for the breast and 0.1 for the lungs). Similar values are achieved by daily 360° kV CBCT (0.44–0.57 per 104 PY for the breast and 0.08 per 104 PY for the lungs), which is again reduced for daily 200° kV CBCT (0.02 per 104 PY for the lungs and 0.07–0.08 per 104 PY for the breast). These values increase if an older attained age is considered (e.g., for 70 years, by a factor of four for the lungs). Conclusions Daily imaging can be performed with an additional secondary cancer risk of less than 1 per 104 PY if kV CBCT is applied. If MV modalities must be chosen, a similar EAR can be achieved with planar images. A further reduction in risk is possible if the imaging geometry allows for sparing of the breast by a partial rotation underneath the patient

    mARC Treatment of Hypopharynx Carcinoma with Flat and Flattening-Filter-Free Beam Energies – A Planning Study

    No full text
    <div><p>Background</p><p>The recently implemented mARC-rotation-technique is capable to deliver high dose rate bursts. For the case of hypopharynx cancer plans we evaluate whether the mARC can achieve an advantage in treatment time in comparison to IMRT. These plans consider two arcs with flat and flattening filter free (FFF) beam energies.</p><p>Materials and Methods</p><p>For 8 hypopharynx-cancer patients step-and-shoot-IMRT and mARC plans were created retrospectively using flat and FFF beam energy. The comparison of the plan scenarios considered measures of quality for PTV coverage and sparing of organs at risk. All plans were irradiated on an anthromorphic phantom equipped with thermoluminescent dosimeters to measure scattered dose and treatment times.</p><p>Results</p><p>A visual comparison of the dose distribution did not show a marked preference for either technique or energy. The statistical evaluation yielded significant differences in favor of the mARC technique and the FFF energy. Scattered dose could be decreased markedly by the use of the mARC technique. Treatment times could be reduced up to 3 minutes with the use of mARC in comparison to IMRT. The high dose rate energy results in another time advantage of about 1 minute.</p><p>Conclusions</p><p>All four plan scenarios yielded equally good quality plans. A combination of the mARC technique with FFF 7 MV high dose rate resulted in a decrease of treatment times from about 9 minutes to 5–6 minutes in comparison to 6 MV IMRT.</p></div