2,233 research outputs found

    Modelling the positioning of single needle electrodes for the treatment of breast cancer in a clinical case

    Get PDF
    Background: Breast cancer is the most common cancer in women worldwide and is the second most common cause of cancer death in women. Electrochemotherapy (ECT) used in early-phase clinical trials for the treatment of primary breast cancer resulted in a not complete tumor necrosis in most cases. The present study was undertaken to analyze the feasibility to use ECT to treat patients with histologically proven unifocal ductal breast cancer. In particular, results of ECT treatment in a clinical case are compared with the ones of a simplified 3D dosimetric model. Methods: This clinical study was conducted with the pulse generator Cliniporator Vitae (IGEA, Carpi, Italy). ECT procedures were performed according to ESOPE standard operating procedures. Five single needle electrodes were used with one positioned in the center of the tumor, and the other four distributed around the nodule. Histological images of the resected tumor are compared with the maps of the electric field obtained with a simplified 3D model in Comsol Multiphysics v 4.3. Results: The results of the clinical case demonstrated a reduced efficacy of the ECT treatment described. The proposed simple numerical model of the breast tumor located in a low conductive tissue suggests that this is due to the reduced electric field induced inside the tumor with such 5 electrodes placement. However, where the electric field is predicted higher than the reversible electroporation threshold (E > 400 V/cm), also the histological images confirm the necrosis of the target with a good agreement between the modeled and clinical results. Conclusions: The results suggest the dependence of the effectiveness of the treatment on the careful placement of the electrodes. A detailed planned procedure for the tumor analysis after the treatment is also needed in order to better correlate the single electrode positions and the histological images. Simulation models could be used to identify better electrodes configuration in planning the experimental protocol for ECT treatment of breast tumors

    Transformation-tolerant object recognition in rats revealed by visual priming

    Get PDF
    Successful use of rodents as models for studying object vision crucially depends on the ability of their visual system to construct representations of visual objects that tolerate (i.e., remain relatively unchanged with respect to) the tremendous changes in object appearance produced, for instance, by size and viewpoint variation. Whether this is the case is still controversial, despite some recent demonstration of transformation-tolerant object recognition in rats. In fact, it remains unknown to what extent such a tolerant recognition has a spontaneous, perceptual basis, or, alternatively, mainly reflects learning of arbitrary associative relations among trained object appearances. In this study, we addressed this question by training rats to categorize a continuum of morph objects resulting from blending two object prototypes. The resulting psychometric curve (reporting the proportion of responses to one prototype along the morph line) served as a reference when, in a second phase of the experiment, either prototype was briefly presented as a prime, immediately before a test morph object. The resulting shift of the psychometric curve showed that recognition became biased toward the identity of the prime. Critically, this bias was observed also when the primes were transformed along a variety of dimensions (i.e., size, position, viewpoint, and their combination) that the animals had never experienced before. These results indicate that rats spontaneously perceive different views/appearances of an object as similar (i.e., as instances of the same object) and argue for the existence of neuronal substrates underlying formation of transformation-tolerant object representations in rats

    Mitigation of Automotive Control Modules Hardware Replacement-based Attacks Through Hardware Signature

    Get PDF
    Authentication of hardware modules connected through Controller Area Networks (CAN) in modern vehicles is becoming an increasing security issue. Untrusted modules introduced on the market may alter the secure boot infrastructure of a complex vehicle, thus completely compromising its security. This paper introduces the problem and highlights a preliminary idea for reaching better protection and preventing or limiting this category of attacks

    PSP Framework: A novel risk assessment method in compliance with ISO/SAE-21434

    Get PDF
    As more cars connect to the internet and other devices, the automotive market has become a lucrative target for cyberattacks. This has made the industry more vulnerable to security threats. As a result, car manufacturers and governments are working together to reduce risks and prevent cyberattacks in the automotive sector. However, existing attack feasibility models derived from the information technology field may not always provide accurate assessments of the potential risks faced by Vehicle Electronic Control Units in different operating conditions and domains. This paper introduces the PUNCH Softronix and Politecnico di Torino (PSP) framework to address this issue. This framework is designed to provide accurate assessments compatible with the attack feasibility models defined by the automotive product security standards. The PSP framework utilizes social sentiment analysis to evaluate the real threat risk levels

    LIN-MM: Multiplexed Message Authentication Code for Local Interconnect Network message authentication in road vehicles

    Get PDF
    The automotive market is profitable for cyberattacks with the constant shift toward interconnected vehicles. Electronic Control Units (ECUs) installed on cars often operate in a critical and hostile environment. Hence, both carmakers and governments have supported initiatives to mitigate risks and threats belonging to the automotive domain. The Local Interconnect Network (LIN) is one of the most used communication protocols in the automotive field. Today’s LIN buses have just a few light security mechanisms to assure integrity through Message Authentication Codes (MAC). However, several limitations with strong constraints make applying those techniques to LIN networks challenging, leaving several vehicles still unprotected. This paper presents LIN Multiplexed MAC (LIN-MM), a new approach for exploiting signal modulation to multiplex MAC data with standard LIN communication. LIN-MM allows for transmitting MAC payloads, maintaining full-back compatibility with all versions of the standard LIN protocol

    Rhabdomyolysis induced by co-administration of fluvastatin and colchicine

    Get PDF
    A case of fluvastatin-induced rhabdomyolysis after coadministration of colchicine is reported. A 77 year old man with ischemic heart disease, chronic pericardial effusion, diabetes mellitus, dyslipidemia, arterial hypertension, chronic renal failure (stage 2 of classification of chronic kidney disease of National Kidney Foundation) and chronic gout presented with a generalized muscle pain. The patient had been taking 80 mg/day of fluvastatin for 4 years, and, for four weeks before presentation, he had also been taking a dose of colchicine (1.0 mg daily) for an exacerbation of gout. Investigations confirmed the diagnosis of rhabdomyolysis. Discontinuation of fluvastatin and colchicine therapy and adequate fluid administration resulted in the resolution of clinical and biochemical features of rhabdomyolysis. Although neuromuscular adverse effects of fluvastatin and colchicine are well recognized, rhabdomyolysis is rare, making this is only the second case reported of fluvastatin and colchicine co-administration induced rhabdomyolysis in literature

    The risk of late or advanced presentation of HIV infected patients is still high, associated factors evolve but impact on overall mortality is vanishing over calendar years: Results from the Italian MASTER Cohort

    Get PDF
    BACKGROUND: We aimed at evaluating frequency and factors associated with late presentation and advanced HIV disease and excess risk of death due to these conditions from 1985 to 2013 among naïve HIV infected patients enrolled in the Italian MASTER Cohort. METHODS: All antiretroviral naive adults with available CD4+ T cell count after diagnosis of HIV infection were included. Multivariable logistic regression analysis investigated factors associated either with late presentation or advanced HIV disease. Probabilities of survival were estimated both at year-1 and at year-5 according to the Kaplan-Meier method. Flexible parametric models were used to evaluate changes in risk of death overtime according to late presentation and advanced HIV disease. The analyses were stratified for calendar periods. RESULTS: 19,391 patients were included (54 % were late presenters and 37.6 % were advanced presenters). At multivariable analysis, the following factors were positively associated with late presentation: male gender (OR = 1.29), older age (≥55 years vs. <25 years; OR = 7.45), migration (OR = 1.54), and heterosexual risk factor for HIV acquisition (OR = 1.52) or IDU (OR = 1.27) compared to homosexual risk. Survival rates at year-5 increased steadily and reached 92.1 % for late presenters vs. 97.4 % for non-late presenters enrolled in the period 2004-2009. Using flexible parametric models we found a sustained reduction of hazard ratios over time for any cause deaths between late and non-late presenters over time. Similar results were found for advanced HIV disease. CONCLUSION: Screening polices need to be urgently implemented, particularly in most-at-risk categories for late presentation, such as migrants, older patients and those with heterosexual intercourse or IDU as risk factors for HIV acquisition. Although in recent years the impact of late presentation on survival decreased, about 10 % of patients diagnosed in more recent years remains at increased risk of death over a long-term follow-up

    Low central venous saturation predicts poor outcome in patients with brain injury after major trauma: a prospective observational study

    Get PDF
    Abstract Background Continuous monitoring of central venous oxygen saturation (ScvO2) has been proposed as a prognostic indicator in several pathological conditions, including cardiac diseases, sepsis, trauma. To our knowledge, no studies have evaluated ScvO2 in polytraumatized patients with brain injury so far. Thus, the aim of the present study was to assess the prognostic role of ScvO2 monitoring during first 24 hours after trauma in this patients' population. Methods This prospective, non-controlled study, carried out between April 2006 and March 2008, was performed in a higher level Trauma Center in Florence (Italy). In the study period, 121 patients affected by major brain injury after major trauma were recruited. Inclusion criteria were: 1. Glasgow Coma Scale (GCS) score ≤ 13; 2. an Injury Severity Score (ISS) ≥ 15. Exclusion criteria included: 1. pregnancy; 2. age 2 monitoring within 2 hours from the trauma. Demographic and clinical data were collected, including Abbreviated Injury Scale (AIS), Injury Severity Score (ISS), Simplified Acute Physiologic Score II (SAPS II), Marshall score. The worst values of lactate and ScvO2 within the first 24 hours from trauma, ICU length of stay (LOS), and 28-day mortality were recorded. Results Patients who deceased within 28 days showed higher age (53 ± 16.6 vs 43.8 ± 19.6, P = 0.043), ISS core (39.3 ± 14 vs 30.3 ± 10.1, P 2 resulted significantly lower (66.7% ± 11.9 vs 70.1% ± 8.9 vs, respectively; P = 0.046). Patients with ScvO2 values ≤ 65% also showed higher 28-days mortality rate (31.3% vs 13.5%, P = 0.034), ICU LOS (28.5 ± 15.2 vs 16.6 ± 13.8, P 2 > 65%. Conclusion ScvO2 value less than 65%, measured in the first 24 hours after admission in patients with major trauma and head injury, was associated with higher mortality and prolonged hospitalization.</p

    Nanoscale electro-structural characterisation of ohmic contacts formed on p-type implanted 4H-SiC

    Get PDF
    This work reports a nanoscale electro-structural characterisation of Ti/Al ohmic contacts formed on p-type Al-implanted silicon carbide (4H-SiC). The morphological and the electrical properties of the Al-implanted layer, annealed at 1700°C with or without a protective capping layer, and of the ohmic contacts were studied using atomic force microscopy [AFM], transmission line model measurements and local current measurements performed with conductive AFM
    • …
    corecore