166 research outputs found

    Early Detection of Iatrogenic Pericardial Effusion: Importance of Intracardiac Echocardiography

    Get PDF

    Debate: Do all patients with heart failure require implantable defibrillators to prevent sudden death?

    Get PDF
    Sudden death is a major cause of mortality in patients with ventricular dysfunction. The highest risk occurs among patients with less severe functional impairment. Current methods of risk stratification are inadequate, and a rational therapy for prevention of sudden death is not available. The implantable cardioverter-defibrillator (ICD) has proven to be more effective than drugs in reducing sudden-death risk in some subsets of patients. Empiric ICD therapy, targeting the general population with mild to moderate heart failure, will maximize the impact of such a strategy to prevent sudden death and improve long-term survival

    Importance of abortive shock capability with electrogram storage in cardioverter-defibrillator devices

    Get PDF
    AbstractObjectives. This study evaluates the ability of a third-generation cardioverter-defibrillator to abort energy delivery and the importance of electrogram storage in analyzing the aborted events.Background. In the Cadence Tiered Therapy Defibrillator, when a tachycardia satisfies detection criteria for cardioversion or defibrillation therapy, high voltage capacitors begin charging. The Cadence defibrillator continues monitoring the rhythm during charging and if the rate decreases to below the rate triggering therapy, charging is terminated. This event is registered as an aborted shock. The defibrillator also has the ability to store intracardiac electrogram recordings of the electrical events that precipitate device therapy or aborted shocks.Methods. During a mean follow-up interval of 10 ± 7 months, 55 aborted events were registered by the Cadence defibrillator in 18 of the 49 patients who received it. Thirty-two stored ventricular etectrograms of events leading to aborted shocks were available for analysis in 15 patients.Results. Intracardiac electrogram recordings demonstrated the probable electrical events leading to these aborted shocks included nonsustained ventricular tachycardia (n = 10), nonsustained rapid polymorphic ventricular tachycardia/ventricular fibrillation (n = 2), atrial fibrillation (n = 5), supraventricular tachycardia (n = 2) and electrical noise (n = 13). Eleven patients had a therapeutic intervention initiated as a consequence of the diagnostic information provided by analysis of intracardiac electrogram recordings. Four of the 15 patients had no changes made. During a follow-up period of 9 ± 5 months after therapy was altered, no patient had subsequent aborted shocks. Five patients have had seven appropriate shocks for sustained ventricular tachycardias.Conclusions. The ability of Cadence defibrillator to continue tachycardia sensing during capacitor charging and to abort shock therapy for self-terminating events prevented unnecessary shocks in 18 (37%) of the 49 patients. Intracardiac electrogram recordings were critical for instituting appropriate therapy that may have prevented unnecessary device charging and inappropriate discharges

    Usefulness of electrophysiologic study to determine the clinical tolerance of arrhythmia recurrences during amiodarone therapy

    Get PDF
    The relation of clinical and electrophysiologic variables to outcome was evaluated in 121 patients treated with amiodarone for sustained ventricular tachyarrhythmias. Electrophysiologic study was performed in all patients a mean of 14 days after beginning amiodarone therapy. Forty-six patients who were given oral amiodarone therapy experienced arrhythmia recurrence. Multivariate analysis was performed using 16 clinical and electrophysiologic variables to determine which factors were associated with 1) arrhythmia recurrence and 2) a poorly tolerated arrhythmia recurrence (that is, cardiac arrest or sudden cardiac death) during oral amiodarone therapy. No variable predicted arrhythmia recurrence. Five variables correlated significantly with a poorly tolerated arrhythmia recurrence. Hemodynamic stability of the arrhythmia induced on electrophysiologic testing during amiodarone therapy had the best predictive value (p < 0.001). Younger age, lower ejection fraction, a poorly tolerated rhythm at clinical presentation and absence of left ventricular aneurysm were also associated with a poorly tolerated arrhythmia recurrence.Only 3 of 57 patients who had a well tolerated arrhythmia induced on electrophysiologic testing during amiodarone therapy had recurrence of a poorly tolerated arrhythmia versus 19 of 47 who had hemodynamically unstable arrhythmias induced during amiodarone therapy (p < 0.001). Thus, electrophysiologic testing during amiodarone therapy appears useful in identifying patients who are prone to have catastrophic arrhythmia recurrences and could allow for the institution of additional or alternative modes of therapy

    Atrial septum fat deposition and atrial anatomy assessed by cardiac magnetic resonance: relationship to atrial electrophysiology

    Get PDF
    To assess the prevalence of fat deposition in the atrial septum with and its relationship with 12-lead electrocardiogram (ECG) atrial parameters (PR interval, P wave duration) and the presence of atrial fibrillation

    Characteristics of the phenotype of mixed cardiomyopathy in patients with implantable cardioverter-defibrillators

    Get PDF
    OnlinePublBackground or Purpose The prognosis of mixed cardiomyopathy (CMP) in patients with implanted cardioverter-defbrillators (ICDs) has not been investigated. We aim to study the demographic, clinical, device therapies and survival characteristics of mixed CMP in a cohort of patients implanted with a defbrillator. Methods The term mixed CMP was used to categorise patients with impaired left ventricular ejection fraction attributed to documented non-ischemic triggers with concomitant moderate coronary artery disease. This is a single center observational cohort of 526 patients with a mean follow-up of 8.7±3.5 years. Results There were 42.5% patients with ischemic cardiomyopathy (ICM), 26.9% with non-ischemic cardiomyopathy (NICM) and 30.6% with mixed CMP. Mixed CMP, compared to NICM, was associated with higher mean age (69.1 ± 9.6 years), atrial fibrillation (55.3%) and greater incidence of comorbidities. The proportion of patients with mixed CMP receiving device shocks was 23.6%, compared to 18.4% in NICM and 27% in ICM. The VT cycle length recorded in mixed CMP (281.6 ± 43.1 ms) was comparable with ICM (282.5 ± 44 ms; p = 0.9) and lesser than NICM (297.7±48.7 ms; p=0.1). All-cause mortality in mixed CMP (21.1%) was similar to ICM (20.1%; p=0.8) and higher than NICM (15.6%; p = 0.2). The Kaplan–Meier curves revealed hazards of 1.57 (95% CI: 0.91, 2.68) for mixed CMP compared to NICM. Conclusion In a cohort of patients with ICD, the group with mixed CMP represents a phenotype predominantly comprised of the elderly with a higher incidence of comorbidities. Mixed CMP resembles ICM in terms of number of device shocks and VT cycle length. Trends of long-term prognosis of patients with mixed CMP are worse than NICM and similar to ICM.Deep Chandh Raja, Indira Samarawickrema, Sarat Krishna Menon, Rikvin Singh, Abhinav Mehta, Lukah Q. Tuan, Ulhas Pandurangi, Sanjiv Jain, David J. Callans, Francis E. Marchlinski, Walter P. Abhayaratna, Prashanthan Sanders, Rajeev K. Patha
    • …
    corecore