139 research outputs found

    Mid- and Long-Term Results of Endovascular Treatment in Thoracic Aorta Blunt Trauma

    Get PDF
    Study Aim. Evaluation of results in blunt injury of the thoracic aorta (BAI) endovascular treatment. Materials and Methods. Sixteen patients were treated for BAI. Thirteen patients had associated polytrauma, 4 of these had a serious hypotensive status and 4 had an hemothorax. In the remaining 3, two had a post-traumatic false aneurysm of the isthmus and 1 had a segmental dissection. In those 13 patients a periaortic hematoma was associated to hemothorax in 4. All patients were submitted to an endovascular treatment, in two cases the subclavian artery ostium was intentionally covered. Results. One patient died for disseminated intravascular coagulation. No paraplegia was recorded. No ischemic complications were observed. A type I endoleak was treated by an adjunctive cuff. During the followup (1–9 years) 3 patients were lost. A good patency and no endoleaks were observed in all cases. One infolding and 1 migration of the endografts were corrected by an adjunctive cuff. Conclusion. The medium and long term results of the endovascular treatment of BAI are encouraging with a low incidence rate of mortality and complications. More suitable endo-suite and endografts could be a crucial point for the further improvement of these results

    A Western single-center experience with endoscopic submucosal dissection for early gastrointestinal cancers

    No full text
    Endoscopic submucosal dissection (ESD) has gained worldwide acceptance as a treatment for early gastrointestinal cancers (EGICs). However, the management of these tumors in the Western world is still mainly surgical. Our aim was to evaluate the safety and feasibility of ESD at a European center. Based on the knowledge transferred by one of the most experienced Japanese institutions, we conducted a pilot study on 25 consecutive patients with EGICs located in the esophagus (n = 3), stomach (n = 7), duodenum (n = 1), and colon (n = 14) at our tertiary center over a 2-year-period. The main outcome measurements were complete (R0) resection, as well as en-bloc resection and the management of complications. The R0 and en-bloc resection rates were 100% and 84%, respectively. There were three cases of bleeding and five cases of perforation. With a median follow up of 18 months, two recurrences were observed. We conclude that ESD for early esophageal and gastric cancers is feasible and effective, while colonic ESD requires more expertise

    Outcomes of a new slowly resorbable biosynthetic mesh (Phasix (TM)) in potentially contaminated incisional hernias : a prospective, multi-center, single-arm trial

    Get PDF
    Background: Resorbable biomaterials have been developed to reduce the amount of foreign material remaining in the body after hernia repair over the long-term. However, on the short-term, these resorbable materials should render acceptable results with regard to complications, infections, and reoperations to be considered for repair. Additionally, the rate of resorption should not be any faster than collagen deposition and maturation; leading to early hernia recurrence. Therefore, the objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (Phasix (TM)) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair. Materials and methods: A prospective, multi-center, single-arm trial was conducted at surgical departments in 15 hospitals across Europe. Patients aged >= 18, scheduled to undergo elective Ventral Hernia Working Group Grade 3 hernia repair of a hernia larger than 10 cm(2) were included. Hernia repair was performed with Phasix (TM) Mesh in sublay position when achievable. The primary outcome was the rate of surgical site occurrence (SSO), including infections, that required intervention until 3 months after repair. Results: In total, 84 patients were treated with Phasix (TM) Mesh. Twenty-two patients (26.2%) developed 32 surgical site occurrences. These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula. No significant differences in surgical site occurrence development were found between groups repaired with or without component separation technique, and between clean-contaminated or contaminated wound sites. At three months, there were no hernia recurrences. Conclusion: Phasix (TM) Mesh demonstrated acceptable postoperative surgical site occurrence rates in patients with a Ventral Hernia Working Group Grade 3 hernia. Longer follow-up is needed to evaluate the recurrence rate and the effects on quality of life. This study is ongoing through 24 months of follow-up

    Lichtenstein's operation, mesh plug, or prolene hernia system repair for groin hernia: which is better?

    No full text
    Comment on Zhao G, Gao P, Ma B, Tian J, Yang K. Open mesh techniques for inguinal hernia repair: a meta-analysis of randomized controlled trials Ann Surg. 2009; 250(1): 35-4

    MESH PLUG REPAIR AND SURGEON'S SATISFACTION

    No full text
    MESH PLUG REPAIR AND SURGEON'S SATISFACTIO
    • 

    corecore