60 research outputs found

    Transmission-dominated mid-infrared supermirrors with finesse exceeding 200 000

    Full text link
    We fabricate and characterize substrate-transferred single-crystal mirror coatings with 9.33 ±\pm 0.17 ppm of transmittance and 4.27 ±\pm 0.52 ppm of excess optical loss, corresponding to a transmission-loss dominated reflectance of 99.9986% at 4.45 μ\mum. For the first time, a cavity finesse > 200 000 is achieved in the mid-infrared.Comment: Sept 21: Minor revisions to conform to 2-page length requirement including abbr. refs.; Figure font sizes increase

    Direct frequency comb measurement of OD + CO → DOCO kinetics

    Get PDF
    The kinetics of the hydroxyl radical (OH) + carbon monoxide (CO) reaction, which is fundamental to both atmospheric and combustion chemistry, are complex because of the formation of the hydrocarboxyl radical (HOCO) intermediate. Despite extensive studies of this reaction, HOCO has not been observed under thermal reaction conditions. Exploiting the sensitive, broadband, and high-resolution capabilities of time-resolved cavity-enhanced direct frequency comb spectroscopy, we observed deuteroxyl radical (OD) + CO reaction kinetics and detected stabilized trans-DOCO, the deuterated analog of trans-HOCO. By simultaneously measuring the time-dependent concentrations of the trans-DOCO and OD species, we observed unambiguous low-pressure termolecular dependence of the reaction rate coefficients for N_2 and CO bath gases. These results confirm the HOCO formation mechanism and quantify its yield

    Mid-infrared interference coatings with excess optical loss below 10 ppm

    Get PDF
    Low excess optical loss, combined absorption and scatter loss, is a key performance metric for any high-reflectance coating technology and is currently one of the main limiting factors for the application of optical resonators in the mid-infrared spectral region. Here we present high-reflectivity substrate-transferred single-crystal GaAs/AlGaAs interference coatings at a center wavelength of 4.54 µm with record-low excess optical loss below 10 parts per million. These high-performance mirrors are realized via a novel microfabrication process that differs significantly from the production of amorphous multilayers generated via physical vapor deposition processes. This new process enables reduced scatter loss due to the low surface and interfacial roughness, while low background doping in epitaxial growth ensures strongly reduced absorption. We report on a suite of optical measurements, including cavity ring-down, transmittance spectroscopy, and direct absorption tests to reveal the optical losses for a set of prototype mirrors. In the course of these measurements, we observe a unique polarization-orientation-dependent loss mechanism which we attribute to elastic anisotropy of these strained epitaxial multilayers. A future increase in layer count and a corresponding reduction of transmittance will enable optical resonators with a finesse in excess of 100,000 in the mid-infrared spectral region, allowing for advances in high-resolution spectroscopy, narrow-linewidth laser stabilization, and ultrasensitive measurements of various light–matter interactions

    Broadband reduction of quantum radiation pressure noise via squeezed light injection

    Get PDF
    The Heisenberg uncertainty principle states that the position of an object cannot be known with infinite precision, as the momentum of the object would then be totally uncertain. This momentum uncertainty then leads to position uncertainty in future measurements. When continuously measuring the position of an object, this quantum effect, known as back-action, limits the achievable precision1,2. In audio-band, interferometer-type gravitational-wave detectors, this back-action effect manifests as quantum radiation pressure noise (QRPN) and will ultimately (but does not yet) limit sensitivity3. Here, we present the use of a quantum engineered state of light to directly manipulate this quantum back-action in a system where it dominates the sensitivity in the 10–50 kHz range. We observe a reduction of 1.2 dB in the quantum back-action noise. This experiment is a crucial step in realizing QRPN reduction for future interferometric gravitational-wave detectors and improving their sensitivity

    The Paired Availability Design for Historical Controls

    Get PDF
    BACKGROUND: Although a randomized trial represents the most rigorous method of evaluating a medical intervention, some interventions would be extremely difficult to evaluate using this study design. One alternative, an observational cohort study, can give biased results if it is not possible to adjust for all relevant risk factors. METHODS: A recently developed and less well-known alternative is the paired availability design for historical controls. The paired availability design requires at least 10 hospitals or medical centers in which there is a change in the availability of the medical intervention. The statistical analysis involves a weighted average of a simple "before" versus "after" comparison from each hospital or medical center that adjusts for the change in availability. RESULTS: We expanded requirements for the paired availability design to yield valid inference. (1) The hospitals or medical centers serve a stable population. (2) Other aspects of patient management remain constant over time. (3) Criteria for outcome evaluation are constant over time. (4) Patient preferences for the medical intervention are constant over time. (5) For hospitals where the intervention was available in the "before" group, a change in availability in the "after group" does not change the effect of the intervention on outcome. CONCLUSION: The paired availability design has promise for evaluating medical versus surgical interventions, in which it is difficult to recruit patients to a randomized trial

    Comparing breast cancer mortality rates before-and-after a change in availability of screening in different regions: Extension of the paired availability design

    Get PDF
    BACKGROUND: In recent years there has been increased interest in evaluating breast cancer screening using data from before-and-after studies in multiple geographic regions. One approach, not previously mentioned, is the paired availability design. The paired availability design was developed to evaluate the effect of medical interventions by comparing changes in outcomes before and after a change in the availability of an intervention in various locations. A simple potential outcomes model yields estimates of efficacy, the effect of receiving the intervention, as opposed to effectiveness, the effect of changing the availability of the intervention. By combining estimates of efficacy rather than effectiveness, the paired availability design avoids confounding due to different fractions of subjects receiving the interventions at different locations. The original formulation involved short-term outcomes; the challenge here is accommodating long-term outcomes. METHODS: The outcome is incident breast cancer deaths in a time period, which are breast cancer deaths that were diagnosed in the same time period. We considered the plausibility of the basic five assumptions of the paired availability design and propose a novel analysis to accommodate likely violations of the assumption of stable screening effects. RESULTS: We applied the paired availability design to data on breast cancer screening from six counties in Sweden. The estimated yearly change in incident breast cancer deaths per 100,000 persons ages 40–69 (in most counties) due to receipt of screening (among the relevant type of subject in the potential outcomes model) was -9 with 95% confidence interval (-14, -4) or (-14, -5), depending on the sensitivity analysis. CONCLUSION: In a realistic application, the extended paired availability design yielded reasonably precise confidence intervals for the effect of receiving screening on the rate of incident breast cancer death. Although the assumption of stable preferences may be questionable, its impact will be small if there is little screening in the first time period. However, estimates may be substantially confounded by improvements in systemic therapy over time. Therefore the results should be interpreted with care

    Direct frequency comb measurement of OD + CO → DOCO kinetics

    Get PDF
    The kinetics of the hydroxyl radical (OH) + carbon monoxide (CO) reaction, which is fundamental to both atmospheric and combustion chemistry, are complex because of the formation of the hydrocarboxyl radical (HOCO) intermediate. Despite extensive studies of this reaction, HOCO has not been observed under thermal reaction conditions. Exploiting the sensitive, broadband, and high-resolution capabilities of time-resolved cavity-enhanced direct frequency comb spectroscopy, we observed deuteroxyl radical (OD) + CO reaction kinetics and detected stabilized trans-DOCO, the deuterated analog of trans-HOCO. By simultaneously measuring the time-dependent concentrations of the trans-DOCO and OD species, we observed unambiguous low-pressure termolecular dependence of the reaction rate coefficients for N_2 and CO bath gases. These results confirm the HOCO formation mechanism and quantify its yield
    • …
    corecore