4 research outputs found

    Dispersion-corrected extracorporeal arterial input functions in PET studies of mice: a comparison to intracorporeal microprobe measurements

    No full text
    Abstract Background Kinetic modelling of dynamic PET typically requires knowledge of the arterial radiotracer concentration (arterial input function, AIF). Its accurate determination is very difficult in mice. AIF measurements in an extracorporeal shunt can be performed; however, this introduces catheter dispersion. We propose a framework for extracorporeal dispersion correction and validated it by comparison to invasively determined intracorporeal AIFs using implanted microprobes. Results The response of an extracorporeal radiation detector to radioactivity boxcar functions, characterised by a convolution-based dispersion model, gave best fits using double-gamma variate and single-gamma variate kernels compared to mono-exponential kernels for the investigated range of flow rates. Parametric deconvolution with the optimal kernels was performed on 9 mice that were injected with a bolus of 39 ± 25 MBq [18F]F-PSMA-1007 after application of an extracorporeal circulation for three different flow rates in order to correct for dispersion. Comparison with synchronous implantation of microprobes for invasive aortic AIF recordings showed favourable correspondence, with no significant difference in terms of area-under-curve after 300 s and 5000 s. One-tissue and two-tissue compartment model simulations were performed to investigate differences in kinetic parameters between intra- and extracorporeally measured AIFs. Results of the modelling study revealed kinetic parameters close to the chosen simulated values in all compartment models. Conclusion The high correspondence of simultaneously intra- and extracorporeally determined AIFs and resulting model parameters establishes a feasible framework for extracorporeal dispersion correction. This should allow more precise and accurate kinetic modelling in small animal experiments

    Translational imaging of the fibroblast activation protein (FAP) using the new ligand [68Ga]Ga-OncoFAP-DOTAGA

    No full text
    Purpose The fibroblast activation protein (FAP) is an emerging target for molecular imaging and therapy in cancer. OncoFAP is a novel small organic ligand for FAP with very high affinity. In this translational study, we establish [Ga-68]Ga-OncoFAP-DOTAGA (Ga-68-OncoFAP) radiolabeling, benchmark its properties in preclinical imaging, and evaluate its application in clinical PET scanning. Methods Ga-68-OncoFAP was synthesized in a cassette-based fully automated labeling module. Lipophilicity, affinity, and serum stability of Ga-68-OncoFAP were assessed by determining logD(7.4), IC50 values, and radiochemical purity. Ga-68-OncoFAP tumor uptake and imaging properties were assessed in preclinical dynamic PET/MRI in murine subcutaneous tumor models. Finally, biodistribution and uptake in a variety of tumor types were analyzed in 12 patients based on individual clinical indications that received 163 +/- 50 MBq Ga-68-OncoFAP combined with PET/CT and PET/MRI. Results Ga-68-OncoFAP radiosynthesis was accomplished with high radiochemical yields. Affinity for FAP, lipophilicity, and stability of Ga-68-OncoFAP measured are ideally suited for PET imaging. PET and gamma counting-based biodistribution demonstrated beneficial tracer kinetics and high uptake in murine FAP-expressing tumor models with high tumor-to-blood ratios of 8.6 +/- 5.1 at 1 h and 38.1 +/- 33.1 at 3 h p.i. Clinical Ga-68-OncoFAP-PET/CT and PET/MRI demonstrated favorable biodistribution and kinetics with high and reliable uptake in primary cancers (SUVmax 12.3 +/- 2.3), lymph nodes (SUVmax 9.7 +/- 8.3), and distant metastases (SUVmax up to 20.0). Conclusion Favorable radiochemical properties, rapid clearance from organs and soft tissues, and intense tumor uptake validate Ga-68-OncoFAP as a powerful alternative to currently available FAP tracers.ISSN:1619-7070ISSN:1619-708

    Confirmation of the topology of the Wendelstein 7-X magnetic field to better than 1:100,000

    No full text
    Fusion energy research has in the past 40 years focused primarily on the tokamak concept, but recent advances in plasma theory and computational power have led to renewed interest in stellarators. The largest and most sophisticated stellarator in the world, Wendelstein 7-X (W7-X), has just started operation, with the aim to show that the earlier weaknesses of this concept have been addressed successfully, and that the intrinsic advantages of the concept persist, also at plasma parameters approaching those of a future fusion power plant. Here we show the first physics results, obtained before plasma operation: that the carefully tailored topology of nested magnetic surfaces needed for good confinement is realized, and that the measured deviations are smaller than one part in 100,000. This is a significant step forward in stellarator research, since it shows that the complicated and delicate magnetic topology can be created and verified with the required accuracy

    Major results from the first plasma campaign of the Wendelstein 7-X stellarator

    No full text
    After completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 1019 m-3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.Peer reviewe
    corecore