11 research outputs found
1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections
PURPOSE:The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner.METHODS:A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length.RESULTS: Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1–5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min.CONCLUSION:1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus
Magnetic resonance neurography: technical considerations
Proper performance of magnetic resonance neurography (MRN) is essential not only to make the examination easier to interpret but also for its accurate evaluation. This article outlines the technical considerations of MRN, various imaging pulse sequences available on current scanners, as well as their relative advantages and disadvantages. In addition, a guide to the optimal use of high-resolution and high-contrast MRN technique is provided, which will aid clinicians in attaining a good-quality examination
Patellofemoral friction syndrome: magnetic resonance imaging correlation of morphologic and T2 cartilage imaging
This study aimed to investigate whether patellofemoral T2 cartilage changes are associated with lateral patellofemoral friction syndrome (PFS), as indicated by an edema-like signal within the superolateral infrapatellar (Hoffa) fat pad.
In this institutional review board-approved retrospective study of 510 consecutive patients, 49 patients with 50 knee magnetic resonance imaging examinations demonstrating normal or low-grade patellofemoral cartilage abnormalities (whole-organ magnetic resonance imaging score [WORMS] score, ≤2) were included. Twenty-two examinations with PFS (cases) were compared with an age- and sex-matched cohort of 28 examinations without PFS (controls). A 3-T magnetic resonance imaging was performed with multi-echo, spin-echo T2 mapping. Two readers measured in consensus malalignment parameters, including patellar height index, tibial tuberosity to trochlear groove distance, and sulcus angle. Bulk T2 cartilage values in the lateral and medial patellofemoral compartment, central weight-bearing medial and lateral femoral condyles were measured independently. Interobserver agreement was quantified using concordance correlation coefficients. Demographics, anatomic measurements, whole-organ magnetic resonance imaging scores, and cartilage T2 values were compared between cases and controls using Fisher exact test, Wilcoxon rank sum test, and mixed-effects models.
Cases demonstrated higher patellar height index (P = 0.002) and tibial tuberosity to trochlear groove distance (P = 0.02). Interobserver agreement for T2 values was good overall (concordance correlation coefficient range, 0.65-0.93). Cases demonstrated higher medial facet patellar bulk T2 (38.1 [7.5] ms) versus controls (33.6 [7.3] ms) (P = 0.02); otherwise, there were no significant differences in regional T2 values.
T2 mapping in patients with PFS demonstrates increased cartilage T2 in the medial patellar facet, possibly reflecting collagen alteration from early chondromalacia (softening) or increased water content related to altered contact pressures
Recommended from our members
The application of three-dimensional diffusion-weighted PSIF technique in peripheral nerve imaging of the distal extremities
To evaluate whether the addition of the three-dimensional diffusion-weighted reversed fast imaging with steady state free precession (3D DW-PSIF) sequence improves the identification of peripheral nerves in the distal extremities.
Twelve MR neurography (MRN) studies of the distal upper extremity and 12 MRN studies of distal lower extremity were evaluated. From the 24 subjects who were enrolled, 10 had clinically suspected peripheral neuropathy, whereas 14 suffered from various orthopedic diseases and had no clinical signs of neuropathy. In each examination, the ability to identify each peripheral nerve on T2-weighted and 3D DW-PSIF sequences was evaluated using a semi-quantitative (0-2) scale. Thereafter, a total certainty score was registered for each sequence.
Combining the results of all studies, the mean certainty score was 1.92 ± 0.28 on the 3D DW-PSIF images and 1.50 ± 0.72 on the T2-weighted images (P < 0.001). In the upper extremity studies, the corresponding certainty scores were 2.0 and 1.70 ± 0.55, respectively (P = 0.008), and in the lower extremity studies, 1.86 ± 0.35 and 1.36 ± 0.79, respectively (P < 0.001).
The 3D DW-PSIF images provide improved identification of the nerves compared with the T2-weighted images, and should be incorporated in the MRN protocol, whenever accurate nerve localization and/or presurgical evaluation are required
MR neurography: past, present, and future
OBJECTIVE: MR neurography (MRN) has increasingly been used in clinical practice for the evaluation of peripheral nerve disease. This article reviews the historic perspective of MRN, the current imaging trends of this modality, and the future directions and applications that have shown potential for improved imaging and diagnostic capabilities. CONCLUSION: MRN has come a long way in the past 2 decades. Excellent depiction of 3D nerve anatomy and pathology is currently possible. Further technical developments in diffusion-based nerve and muscle imaging, whole-body MRN, and nerve-specific MR contrast agents will likely play a major role in advancing this novel field and understanding peripheral neuromuscular diseases in the years to come