9,474 research outputs found
Nuclear systems in space? Does/will the public accept them?
Public attitudes toward the use of nuclear energy on earth and in space are discussed. Survey data are presented which show that the public believes nuclear energy should play an important role in our energy supply. However, based on broad attitude research, there should be no expectation that the public will accept or support the use of nuclear energy unless it meets special needs and offers special and significant benefits. It is proposed that a public information program be adopted that results in getting recognition and support for the space program broadly and for the missions that benefit substantially from or require nuclear energy for their accomplishment
Discovery of Pulsed X-ray Emission from the SMC Transient RX J0117.6-7330
We report on the detection of pulsed, broad-band, X-ray emission from the
transient source RX J0117.6-7330. The pulse period of 22 seconds is detected by
the ROSAT/PSPC instrument in a 1992 Sep 30 - Oct 2 observation and by the
CGRO/BATSE instrument during the same epoch. Hard X-ray pulsations are
detectable by BATSE for approximately 100 days surrounding the ROSAT
observation (1992 Aug 28 - Dec 8). The total directly measured X-ray luminosity
during the ROSAT observation is 1.0E38 (d/60 kpc)^2 ergs s-1. The pulse
frequency increases rapidly during the outburst, with a peak spin-up rate of
1.2E-10 Hz s-1 and a total frequency change 1.8%. The pulsed percentage is
11.3% from 0.1-2.5 keV, increasing to at least 78% in the 20-70 keV band. These
results establish RX J0117.6-7330 as a transient Be binary system.Comment: 17 pages, Latex, aasms, accepted for publication in ApJ Letter
Mid-Infrared Instrumentation for the European Extremely Large Telescope
MIDIR is the proposed thermal/mid-IR imager and spectrograph for the European
Extremely Large Telescope (E-ELT). It will cover the wavelength range of 3 to
at least 20 microns. Designed for diffraction-limited performance over the
entire wavelength range, MIDIR will require an adaptive optics system; a
cryogenically cooled system could offer optimal performance in the IR, and this
is a critical aspect of the instrument design. We present here an overview of
the project, including a discussion of MIDIR's science goals and a comparison
with other infrared (IR) facilities planned in the next decade; top level
requirements derived from these goals are outlined. We describe the optical and
mechanical design work carried out in the context of a conceptual design study,
and discuss some important issues to emerge from this work, related to the
design, operation and calibration of the instrument. The impact of telescope
optical design choices on the requirements for the MIDIR instrument is
demonstrated.Comment: for publication in SPIE Proceedings vol. 6692, Cryogenic Optical
Systems and Instrumentation XII, eds. J.B. Heaney and L.G. Burriesci, San
Diego, Aug 200
Long-term source monitoring with BATSE
The uncollimated Burst and Transient Source Experiment (BATSE) large area detectors (LADs) are well suited to nearly continuous monitoring of the stronger hard x-ray sources, and time series analysis for pulsars. An overview of the analysis techniques presently being applied to the data are discussed, including representative observations of the Crab Nebula, Crab pulsar, and summaries of the sources detected to data. Results of a search for variability in the Crab Pulsar pulse profile are presented
Force Modulating Dynamic Disorder: Physical Theory of Catch-slip bond Transitions in Receptor-Ligand Forced Dissociation Experiments
Recently experiments showed that some adhesive receptor-ligand complexes
increase their lifetimes when they are stretched by mechanical force, while the
force increase beyond some thresholds their lifetimes decrease. Several
specific chemical kinetic models have been developed to explain the intriguing
transitions from the "catch-bonds" to the "slip-bonds". In this work we suggest
that the counterintuitive forced dissociation of the complexes is a typical
rate process with dynamic disorder. An uniform one-dimension force modulating
Agmon-Hopfield model is used to quantitatively describe the transitions
observed in the single bond P-selctin glycoprotein ligand
1(PSGL-1)P-selectin forced dissociation experiments, which were respectively
carried out on the constant force [Marshall, {\it et al.}, (2003) Nature {\bf
423}, 190-193] and the force steady- or jump-ramp [Evans {\it et al.}, (2004)
Proc. Natl. Acad. Sci. USA {\bf 98}, 11281-11286] modes. Our calculation shows
that the novel catch-slip bond transition arises from a competition of the two
components of external applied force along the dissociation reaction coordinate
and the complex conformational coordinate: the former accelerates the
dissociation by lowering the height of the energy barrier between the bound and
free states (slip), while the later stabilizes the complex by dragging the
system to the higher barrier height (catch).Comment: 8 pages, 3 figures, submitte
Monitoring Cen X-3 with BATSE
The eight uncollimated BATSE Large Area Detectors (LAD's) provide the ability to monitor pulsed hard x ray sources on a nearly continuous basis. Using data from the LAD's, the pulse timing and pulsed flux of the 4.8 second period binary x ray pulsar Centaurus X-3 was analyzed over a two month period. The methods and initial results of this analysis, which includes both data folded onboard GRO and 1.024 second resolution discriminator rates folded on the ground, are presented
Occultation analysis of BATSE data: Operational aspects
The Burst and Transient Source Experiment (BATSE) large area detectors are being used to monitor hard x-ray/gamma ray sources on a daily basis for evidence of transient behavior. Flux measurements are performed using a simple earth occultation technique. Daily searches are also being performed to detect occultation steps of sources which are not being routinely monitored. Topics concerning the operational aspects of the occultation measurements are presented. Preliminary spectral results are also presented for several of the brighter sources
Performance of a 13-Stage Development Compressor for the J40-WE-24 Engine at Equivalent Speeds from 30 to 112 Percent of Design
The performance of a 13-stage development comressor for the J40-WE-24 engine has been determined at equivalent speeds from 30 to 112 percent of design. The design total-pressure ratio of 6.0 and the design weight flow of 164 pounds per second were not attained, An analysis was conducted to determine the reasons for the poor performance at the design and over-design speed. The analysis indicated that most of the difficulty could be attributed to the fact that the first stage was overcompromised to favor part-speed performance
Performance of the 19XB 10-Stage Axial-Flow Compressor with Altered Blade Angles
Previous performance data of the 19XB axial-flow compressor indicated that the outlet guide vanes and possibly the inlet guide vanes were stalling. Calculations were made to determine if these adverse conditions could be eliminated and if the manufacturer's design specifications could be more nearly approached by altering the blade angles of the first few compression stages as well as the outlet guide vanes. With the blade angles altered, experimental data were taken at compressor speeds of 8500 to 17,000 rpm with inlet-air conditions of 7.4 inches of mercury absolute and 59 0 F. The temperature-rise efficiency increased with speed from 0.70 at 8500 rpm to 0.74 at 13,600 rpm and dropped gradually to 0.70 at 17,000 rpm. At the design speed of 17,000 rpm, the pressure ratio at the peak efficiency point was 3.63. The maximum pressure ratio at design speed was 4.15 at an equivalent weight flow of 29.8 pounds per second. The altered compressor operated very .near the design specifications of pressure ratio and equivalent weight flow. At the high speeds, the peak adiabatic temperature-rise efficiency was increased 0.02 to 0,06 by altering the blade angles. The peak pressure ratio was increased 0.29 at design speed (17,000 rpm) and 0.05 and 0.13 at 11,900 and 13,600 rpm, respectively. The equivalent weight flow through the altered compressor was reduced 2 pounds per second at 15,300 and 17,000 rpm, as was expected from the design calculations. As extreme caution was taken not to surge the compressor violently, the point of minimum air flow may not have been reached in the present investigation and in a previous investigation. A true comparison of the pressure ratios obtained at the high speeds therefore cannot be made
- …