37 research outputs found

    Corrective Osteotomy in a Patient With Congenital Absence of Pronation Based on Three-Dimensional Statistical Shape Modeling

    Get PDF
    We present a new indication of a three-dimensional statistical shape model (SSM): a patient with bilateral impaired forearm rotation due to a congenital variance in bone shape. A corrective osteotomy was planned and performed to best match the SSM created by computed tomography (CT) scans of 18 peers. Postoperatively, pronation increased by 70°, and the patient was pain-free. A CT scan showed accurate correction of the deformity and union of all osteotomies. This technique offers opportunities for patients with bilateral nontraumatic osseous forearm pathology.</p

    Arthroscopic Subtalar Arthrodesis after a Calcaneus Fracture Covered with a Forearm Flap

    Get PDF
    Surgical treatment of intraarticular calcaneal fractures is often associated with postoperative wound problems. Soft tissue necrosis, bone loss and uncontrollable infection are a challenge for the surgeon and amputation may in some cases be the ultimate solution. A free flap can be very helpful to cover a significant soft tissue defect and help in fighting the infection. However, the free flap complicates the surgical approach if subtalar arthrodesis and bone reconstruction are needed. This study demonstrates the value of an arthroscopic technique to resect the remaining articular cartilage in preparation for subtalar arthrodesis and bone grafting. This approach avoids compromising the soft tissues and minimizes damage to the free flap

    Quantification of 3D microstructural parameters of trabecular bone is affected by the analysis software

    Get PDF
    Over the last decades, the use of high-resolution imaging systems to assess bone microstructural parameters has grown immensely. Yet, no standard defining the quantification of these parameters exists. It has been reported that different voxel size and/or segmentation techniques lead to different results. However, the effect of the evaluation software has not been investigated so far. Therefore, the aim of this study was to compare the bone microstructural parameters obtained with two commonly used commercial software packages, namely IPL (Scanco, Switzerland) and CTan (Bruker, Belgium). We hypothesized that even when starting from the same segmented scans, different software packages will report different results. Nineteen trapezia and nineteen distal radii were scanned at two resolutions (20 mu m voxel size with microCT and HR-pQCT 60 mu m). The scans were segmented using the scanners' default protocol. The segmented images were analyzed twice, once with IPL and once with CTan, to quantify bone volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N) and specific bone surface (BS/BV). Only small differences between IPL and CTan were found for BV/TV. For Tb.Th, Tb.Sp and BS/BV high correlations (R-2 >= 0.99) were observed between the two software packages, but important relative offsets were observed. For microCT scans, the offsets were relative constant, e.g., around 15% for Tb.Th. However, for the HR-pQCT scans the mean relative offsets ranged over the different bone samples (e.g., for Tb.Th from 14.5% to 19.8%). For Tb.N, poor correlations (0.43 We conclude that trabecular bone microstructural parameters obtained with IPL and CTan cannot be directly compared except for BV/TV. For Tb.Th, Tb.Sp and BS/BV, correction factors can be determined, but these depend on both the image voxel size and specific anatomic location. The two software packages did not produce consistent data on Tb.N. The development of a universal standard seems desirable

    High-Resolution Cone-Beam Computed Tomography is a Fast and Promising Technique to Quantify Bone Microstructure and Mechanics of the Distal Radius

    Get PDF
    Obtaining high-resolution scans of bones and joints for clinical applications is challenging. HR-pQCT is considered the best technology to acquire high-resolution images of the peripheral skeleton in vivo, but a breakthrough for widespread clinical applications is still lacking. Recently, we showed on trapezia that CBCT is a promising alternative providing a larger FOV at a shorter scanning time. The goals of this study were to evaluate the accuracy of CBCT in quantifying trabecular bone microstructural and predicted mechanical parameters of the distal radius, the most often investigated skeletal site with HR-pQCT, and to compare it with HR-pQCT. Nineteen radii were scanned with four scanners: (1) HR-pQCT (XtremeCT, Scanco Medical AG, @ (voxel size) 82 mu m), (2) HR-pQCT (XtremeCT-II, Scanco, @60.7 mu m), (3) CBCT (NewTom 5G, Cefla, @75 mu m) reconstructed and segmented using in-house developed software and (4) microCT (VivaCT40, Scanco, @19 mu m-gold standard). The following parameters were evaluated: predicted stiffness, strength, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th), separation (Tb.Sp) and number (Tb.N). The overall accuracy of CBCT with in-house optimized algorithms in quantifying bone microstructural parameters was comparable (R-2 = 0.79) to XtremeCT (R-2 = 0.76) and slightly worse than XtremeCT-II (R-2 = 0.86) which were both processed with the standard manufacturer's technique. CBCT had higher accuracy for BV/TV and Tb.Th but lower for Tb.Sp and Tb.N compared to XtremeCT. Regarding the mechanical parameters, all scanners had high accuracy (R-2 >= 0.96). While HR-pQCT is optimized for research, the fast scanning time and good accuracy renders CBCT a promising technique for high-resolution clinical scanning

    Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides.</p> <p>Methods/Design</p> <p>This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months postoperatively.</p> <p>Discussion</p> <p>Computer-assisted surgical planning, combined with patient-specific surgical guides, is a powerful new technology that has the potential to improve the accuracy and consistency of orthopaedic surgery. To date, the role of this technology in upper extremity surgery has not been adequately investigated, and it is unclear whether its use provides any significant clinical benefit over traditional preoperative imaging protocols. Our study will represent the first randomized controlled trial investigating the use of computer assisted surgery in corrective osteotomy for distal radius malunions.</p> <p>Trial registration</p> <p>NCT01193010</p

    Accuracy of 3D Virtual Planning of Corrective Osteotomies of the Distal Radius

    No full text
    Corrective osteotomies of the distal radius for symptomatic malunion are time-tested procedures that rely on accurate corrections. Patients with combined intra- and extra-articular malunions present a challenging deformity. Virtual planning and patient-specific instruments (PSIs) to transfer the planning into the operating room have been used both to simplify the surgery and to make it more accurate. This report focuses on the clinically achieved accuracy in four patients treated between 2008 and 2012 with virtual planning and PSIs for a combined intra- and extraarticular malunion of the distal radius. The accuracy of the correction is quantified by comparing the virtual three-dimensional (3D) planning model with the postoperative 3D bone model. For the extraarticular malunion the 3D volar tilt, 3D radial inclination and 3D ulnar variance are measured. The volar tilt is undercorrected in all cases with an average of -6 ± 6°. The average difference between the postoperative and planned 3D radial inclination was -1 ± 5°. The average difference between the postoperative and planned 3D ulnar variances is 0 ± 1 mm. For the evaluation of the intraarticular malunion, both the arc method of measurement and distance map measurement are used. The average postoperative maximum gap is 2.1 ± 0.9 mm. The average maximum postoperative step-off is 1.3 ± 0.4 mm. The average distance between the postoperative and planned articular surfaces is 1.1 ± 0.6 mm as determined in the distance map measurement. There is a tendency to achieve higher accuracy as experience builds up, both on the surgeon's side and on the design engineering side. We believe this technology holds the potential to achieve consistent accuracy of very complex corrections.status: publishe

    Alternatives to arthroplasty in trapezio-metacarpal osteoartritis

    No full text
    status: publishe

    Thrombosis in injured small vessels

    No full text
    status: publishe

    consensus in aanpak van patiënten met laterale instabiliteit van de enkel

    No full text
    status: publishe

    The effect of orthoses on the kinematics of the trapeziometacarpal, scaphotrapeziotrapezoidal, and radioscaphoid joints

    No full text
    The in vivo effect of four different types of thumb and thumb-wrist orthoses on the three-dimensional kinematics of the trapeziometacarpal (TMC), scaphotrapeziotrapezoidal (STT) and radioscaphoid joints was quantified using computed tomography (CT). Eighteen healthy female volunteers were recruited. The dominant hand of each subject was scanned in four thumb and wrist positions, each in three conditions: without orthosis, with a thumb orthosis (Push Ortho and immediate fitting, IMF) and with a thumb-wrist orthosis (Ligaflex Manu and IMF). CT images were analyzed and rotations relative to the more proximal bone were expressed in a joint-specific coordinate system. Without orthosis, the largest STT rotations were observed during radioulnar deviation of the wrist and the STT range of motion (ROM) was significantly lower during wrist flexion-extension. All tested orthoses caused a significant reduction of the ROM at each joint compared to free motion. Significant differences in movement reduction were observed between prefabricated and IMF orthoses.The IMF thumb-wrist outperformed the Ligaflex Manu in terms of immobilization of the radioscaphoid joint. In addition, the IMF thumb orthosis immobilized the TMC joint significantly better during thumb abduction and adduction than the Push Ortho. We found that different types of thumb and thumb-wrist orthotics are effective in reducing joint mobility. While this reduction tends to be higher using IMF compared to prefabricated orthoses, this effect is only significant for the radioscaphoid and TMC joint. The finding that thumb movements do not induce large STT rotations suggests that the thumb does not need to be immobilized in case of isolated STT osteoarthritis.status: publishe
    corecore