14 research outputs found

    Safety and efficacy of flow diverter stents in the treatment of middle cerebral artery aneurysms: a single-center experience and follow-up data

    Get PDF
    PURPOSEThis study aims to evaluate the safety and efficacy of flow diverters (FDs) in the treatment of middle cerebral artery (MCA) aneurysms and share the follow-up (F/U) results.METHODSThe treatment and F/U results of 76 MCA aneurysms treated with the flow re-direction endoluminal device (FRED), FRED Jr., and pipeline embolization device (PED) FD stents were evaluated retrospectively. The aneurysm occlusion rates were compared between FDs, and the integrated and jailed branches were evaluated through follow-ups. The oversizing of the stent was compared between occluded/non-occluded aneurysms and integrated branches.RESULTSThe mean F/U duration was 32 ± 6.3 months, and the mean aneurysm diameter was 4.45 mm. A total of 61 (80.3%) aneurysms were wide-necked; 73 (96.1%) were saccular; 52 (68.4%) were located at the M1 segment; and 36 (45.6%) FREDs, 23 (29.1%) FRED Jr.s, and 19 (24.1%) PEDs were used for treatment. The overall occlusion rates for the 6-, 12-, 24-, 36-, and 60-month digital subtraction angiographies were 43.8%, 63.5%, 73.3%, 85.7%, and 87.5% respectively. The last F/U occlusion rates were 67.6% for FRED, 66.7% for PED, and 60.6% for FRED Jr. (P = 0.863). An integrated branch was covered with an FD during the treatment of 63 (82.8%) aneurysms. A total of six (10%) of the integrated branches were occluded without any symptoms at the last F/U appointment. The median oversizing was 0.45 (0–1.30) for occluded aneurysms, and 0.50 (0–1.40) for non-occluded aneurysms (P = 0.323). The median oversizing was 0.70 (0.45–1.10) in occluded integrated branches and 0.50 (0–1.40) in non-occluded branches (P = 0.131). In-stent stenosis was seen in 22 (30.1%) of the stents at the 6-month F/U and in only 2 (4.7%) at the 24-month F/U. Thus, none of the patients had any neurological deficits because of the in-stent stenosis. Severe in-stent stenosis was seen in two stents.CONCLUSIONMCA aneurysms tend to be complex, with integrated branches and potentially wide necks. FD stents are safe and effective in the treatment of MCA aneurysms, and the patency of the side and jailed branches is preserved in most cases. Higher occlusion and lower in-stent stenosis rates are seen with longer F/U durations

    Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting

    No full text
    Objectives: The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. Materials and Methods: This study was conducted as a cross-sectional, non-randomised clinical case series. Fifteen male patients (mean age: 63.6±9.1) with CAS and more than 70% carotid artery narrowing were included. All of the patients were followed in the department of neurology and were operated in the interventional radiology division. Eighteen healthy male subjects (mean age: 63.7±5.3) were included in the control group. All of the healthy subjects had a detailed ophthalmological examination and subjects with any chronic eye disease were excluded from the study. All of the participants had a detailed ophthalmological examination including tonometry using Goldmann applanation tonometry and RNFL analysis using optical coherence tomography (RTVue-100 5.1). Results: There were no ocular ischemic symptoms in any of the participants. The mean IOP value was 15.1±2.1 mmHg in the control group and 16.6±2.4 mmHg before stent implantation, 16.4±2.2 mmHg at 1 week after implantation, 16.6±2.5 mmHg at 1 month after implantation, and 16.7±2.9 mmHg at 3 months after implantation in the CAS group. Mean RNFL thickness was 105±6 µm in the control group; in the CAS group, mean RNFL thickness values were 98±27 µm before stent implantation and 103±11 µm, 101±10 µm, and 101±11 µm at 1 week, 1 month, and 3 months after stenting. There were no significant differences between the CAS group and control group regarding IOP and RNFL thickness values (p>0.05). IOP and RNFL thickness also did not show any statistically significant changes from preoperative measurements in 3 months postoperative follow-up in the CAS group (p>0.05). Conclusion: IOP and RNFL thickness remained unchanged after carotid stent implantation in carotid artery stenosis patients with no signs of ocular ischemic syndrome
    corecore