4 research outputs found

    Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access

    Get PDF
    (1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collected from a population with non-palpable or not visible veins, classified into size risk groups for 6 months. In the comparative analysis, the patients were divided into two groups: the cases group was composed of patients to whom the peripheral venous cannulation was performed with the ultrasound-guided technique (UST), while the control was composed of patients with whom the standard technique (ST) was performed. The ultrasound LOGIQ P5 750VA from General Electric Healthcare, with an 11 mHz linear probe, was utilized, along with peripheral venous catheters model Insyte™ Autoguard™ with gauges of 14G to 26G. (3) Results. Seventy-two cases. The use of the ultrasound decreased the time (618.34s ST, 126s UST) and the number of punctures (2.92 ST, 1.23 UST); about 25% of the patients did not have complications with the UST, as compared to 8% with the ST. The use of the ultrasound decreased the pain experienced by 1.44 points in the visual analog scale, as compared to 0.11 points with the ST. The rate of success of the first try with the UST was 76%, as compared to 16% of the ST. The gauge of the catheter increased with the UST, with successful cannulations obtained with 20G (56%) and 18G (41%) gauges. (4) Conclusions. The use of ultrasound facilitates venous cannulation according to the variables of the study. The ultrasound visualization of the vessels is associated with the selection of the catheter gauge. There was no relation between the complications and the depth of the blood vessels.Enfermerí

    Prevalent Technique and Results of Hemorrhoidal Embolization

    No full text
    Hemorrhoids are blood cushions located in the anus and lower rectum, acknowledged as a common cause of bleeding, which can reduce quality of life. The development of minimally invasive techniques such as endovascular embolization of superior rectal artery, “Emborrhoid technique”, is an effective treatment, with no pain or ischemic complications, and allows quick patient recovery. Our purpose is to describe the general technique and discuss the results of the current literature

    Anatomical variations in the aortic bifurcation in New Zealand white rabbits on arteriography

    No full text
    The radiologic anatomy of the aortic bifurcation in the rabbit has received little study but it is important as this anatomical area is widely used in atherosclerosis research. Thirty rabbits were used to study the aortic bifurcation and subsequent branching patterns on arteriography. Fifteen different arteries were identified. Mean arterial diameters of 2.88 ± 0.7 and 2.27 ± 0.55 mm were obtained for the aorta and external iliac arteries, respectively. The cranial and middle aspects at the seventh lumbar vertebra (L7) were the most frequent anatomical landmarks (53.3% of the cases) for aortic and common iliac bifurcations, respectively. The caudal aspect of L6 was the most frequent origin (50% of the cases) for the median sacral artery. Deep circumflex iliac arteries originated from common iliac arteries and not the abdominal aorta in the rabbit, showing anatomical asymmetry in 73.3% of the cases. No gender disparity was found in the anatomical location of any of the arteries of the study. Knowledge of normal vascular landmarks for the aortic bifurcation as well as anatomical variations should be helpful to future experimental studies

    Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access

    Get PDF
    (1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collected from a population with non-palpable or not visible veins, classified into size risk groups for 6 months. In the comparative analysis, the patients were divided into two groups: the cases group was composed of patients to whom the peripheral venous cannulation was performed with the ultrasound-guided technique (UST), while the control was composed of patients with whom the standard technique (ST) was performed. The ultrasound LOGIQ P5 750VA from General Electric Healthcare, with an 11 mHz linear probe, was utilized, along with peripheral venous catheters model InsyteTM AutoguardTM with gauges of 14G to 26G. (3) Results. Seventy-two cases. The use of the ultrasound decreased the time (618.34s ST, 126s UST) and the number of punctures (2.92 ST, 1.23 UST); about 25% of the patients did not have complications with the UST, as compared to 8% with the ST. The use of the ultrasound decreased the pain experienced by 1.44 points in the visual analog scale, as compared to 0.11 points with the ST. The rate of success of the first try with the UST was 76%, as compared to 16% of the ST. The gauge of the catheter increased with the UST, with successful cannulations obtained with 20G (56%) and 18G (41%) gauges. (4) Conclusions. The use of ultrasound facilitates venous cannulation according to the variables of the study. The ultrasound visualization of the vessels is associated with the selection of the catheter gauge. There was no relation between the complications and the depth of the blood vessels.Sin financiación2.645 JCR (2020) Q2, 40/88 Health Policy & Services0.533 SJR (2021) Q2, 115/273 Health PolicyNo data IDR 2020UE
    corecore