13 research outputs found

    Pontiac fever: an operational definition for epidemiological studies

    Get PDF
    BACKGROUND: Pontiac fever is usually described in epidemic settings. Detection of Pontiac fever is a marker of an environmental contamination by Legionella and should thereby call for prevention measures in order to prevent outbreak of Legionnaire's disease. The objective of this study is to propose an operational definition of Pontiac fever that is amenable to epidemiological surveillance and investigation in a non epidemic setting. METHODS: A population of 560 elderly subjects residing in 25 nursing homes was followed during 4 months in order to assess the daily incidence of symptoms associated, in the literature, with Pontiac fever. The water and aerosol of one to 8 showers by nursing home were characterized combining conventional bacterial culture of Legionella and the Fluorescence In Situ Hybridization (FISH) technique that used oligonucleotides probes specific for Legionellaceae. A definition of Pontiac fever was devised based on clinical symptoms described in epidemic investigations and on their timing after the exposure event. The association between incidence of Pontiac fever and shower contamination levels was evaluated to test the relevance of this definition. RESULTS: The proposed definition of Pontiac fever associated the following criteria: occurrence of at least one symptom among headache, myalgia, fever and shivers, possibly associated with other 'minor' symptoms, within three days after a shower contaminated by Legionella, during a maximum of 8 days (minimum 2 days). 23 such cases occurred during the study (incidence rate: 0.125 cases per person-year [95% CI: 0.122–0.127]). A concentration of Legionella in water equal to or greater than 10(4).L(-1 )(FISH method) was associated with a significant increase of incidence of Pontiac fever (p = 0.04). CONCLUSION: Once validated in other settings, the proposed definition of Pontiac fever might be used to develop epidemiological surveillance and help draw attention on sources of Legionella

    Isolation of Legionella anisa Using an Amoebic Coculture Procedure

    No full text
    Conventional diagnostic tests for legionellosis were negative for a 61-year-old immunocompromised man with pneumonia. However, coculture of a sputum sample with Acanthamoeba polyphaga amoebae led to the recovery of Legionella anisa. This procedure may be a sensitive and convenient diagnostic method, especially for non-Legionella pneumophila species infections that can be diagnosed only by culture

    Cross-transmission in the dental office: Does this make you ill?

    Get PDF
    Purpose of Review: Recently, numerous scientific publications were published which shed new light on the possible risks of infection for dental healthcare workers and their patients. This review aimed to provide the latest insights in the relative risks of transmission of (pathogenic) micro-organisms in the dental office. Recent Findings: Of all different routes of micro-organism transmission during or immediately after dental treatment (via direct contact/via blood-blood contact/via dental unit water and aerosols), evidence of transmission is available. However, the recent results put the risks in perspective; infections related to the dental office are most likely when infection control measures are not followed meticulously. Summary: The risk for transmission of pathogens in a dental office resulting in an infectious disease is still unknown; it seems to be limited in developed countries but it cannot be considered negligible. Therefore, maintaining high standards of infection preventive measures is of high importance for dental healthcare workers to avoid infectious diseases due to cross-contamination

    Confirmed and Potential Sources of Legionella

    No full text

    Enhanced contact investigations for nine early travel-related cases of SARS-CoV-2 in the United States

    No full text
    Coronavirus disease 2019 (COVID-19), the respiratory disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), was first identified in Wuhan, China and has since become pandemic. In response to the first cases identified in the United States, close contacts of confirmed COVID-19 cases were investigated to enable early identification and isolation of additional cases and to learn more about risk factors for transmission. Close contacts of nine early travel-related cases in the United States were identified and monitored daily for development of symptoms (active monitoring). Selected close contacts (including those with exposures categorized as higher risk) were targeted for collection of additional exposure information and respiratory samples. Respiratory samples were tested for SARS-CoV-2 by real-time reverse transcription polymerase chain reaction at the Centers for Disease Control and Prevention. Four hundred four close contacts were actively monitored in the jurisdictions that managed the travel-related cases. Three hundred thirty-eight of the 404 close contacts provided at least basic exposure information, of whom 159 close contacts had ≥1 set of respiratory samples collected and tested. Across all actively monitored close contacts, two additional symptomatic COVID-19 cases (i.e., secondary cases) were identified; both secondary cases were in spouses of travel-associated case patients. When considering only household members, all of whom had ≥1 respiratory sample tested for SARS-CoV-2, the secondary attack rate (i.e., the number of secondary cases as a proportion of total close contacts) was 13% (95% CI: 4–38%). The results from these contact tracing investigations suggest that household members, especially significant others, of COVID-19 cases are at highest risk of becoming infected. The importance of personal protective equipment for healthcare workers is also underlined. Isolation of persons with COVID-19, in combination with quarantine of exposed close contacts and practice of everyday preventive behaviors, is important to mitigate spread of COVID-19
    corecore