Successful MRI-Guided Focused Ultrasound Uterine Fibroid Treatment Despite an Ostomy and Significant Abdominal Wall Scarring
We present a case of successful magnetic resonance imaging-guided focused ultrasound surgery (MRgFUS) of a uterine fibroid in a patient with extensive anterior abdominal wall surgical scars from two longitudinal laparotomies, a total colectomy and ileostomy. This case demonstrates that MRgFUS can be safely used in patients with an ostomy and significant abdominal wall scarring, but careful pretreatment planning and positioning during treatment is needed
Recommended from our members
MR-guided focused ultrasound (MRgFUS) is effective for the distinct pattern of uterine fibroids seen in African-American women: data from phase III/IV, non-randomized, multicenter clinical trials
Background: Uterine fibroids are common among women at the reproductive age. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) is a novel and a conservative treatment for symptomatic cases. The aim of the study was to evaluate the efficacy of MRgFUS in African-American (AA) women compared with that in non-African-Americans (non-AA). Methods: A single-armed phase IV study was conducted to establish the efficacy of treatment in AA women. Comparison of patient, fibroid, and treatment characteristics from this trial was compared with that of the previously published phase III trial. Both studies were approved by the IRB of each medical center. Results: Sixty-three AA and 59 non-AA women were treated with MRgFUS. Although AA women had a different pattern of disease, outcomes were similar in both groups. AA patients had a significant higher total number of fibroids compared with non-AA (median 6.0, interquartile range (IQR) 3.0–10.0 vs. 2.0, IQR 1.0–4.0, respectively, p < 0.001), although their total fibroid volume was significantly smaller (median 196.9 cm3, IQR 112.8–415.3 cm3 vs. 394.8 cm3, IQR 189.8–674.4 cm3, respectively, p < 0.001). AA women were younger compared with non-AA (mean ± SD 43.4 ± 5.1 vs. 46.3 ± 4.1 years of age, respectively, p = 0.001) when they presented for treatment. The rate of alternative treatments as well as fibroid-associated symptoms at follow-up time points (3, 6, 12, 24, and 36 months, period following MRgFUS treatment) did not differ according to race (p ≥ 0.62). Conclusion: Despite differences in the pattern of fibroid disease, MRgFUS for uterine fibroids has a similar efficacy for AA women compared with non-AA women
Recommended from our members
Potential of minimally invasive procedures in the treatment of uterine fibroids: a focus on magnetic resonance-guided focused ultrasound therapy
Minimally invasive treatment options are an important part of the uterine fibroid-treatment arsenal, especially among younger patients and in those who plan future pregnancies. This article provides an overview of the currently available minimally invasive therapy options, with a special emphasis on a completely noninvasive option: magnetic resonance-guided focused ultrasound (MRgFUS). In this review, we describe the background of MRgFUS, the patient-selection criteria for MRgFUS, and how the procedure is performed. We summarize the published clinical trial results, and review the literature on pregnancy post-MRgFUS and on the cost-effectiveness of MRgFUS
Repeatability of Multiparametric Prostate MRI Radiomics Features
In this study we assessed the repeatability of the values of radiomics
features for small prostate tumors using test-retest Multiparametric Magnetic
Resonance Imaging (mpMRI) images. The premise of radiomics is that quantitative
image features can serve as biomarkers characterizing disease. For such
biomarkers to be useful, repeatability is a basic requirement, meaning its
value must remain stable between two scans, if the conditions remain stable. We
investigated repeatability of radiomics features under various preprocessing
and extraction configurations including various image normalization schemes,
different image pre-filtering, 2D vs 3D texture computation, and different bin
widths for image discretization. Image registration as means to re-identify
regions of interest across time points was evaluated against human-expert
segmented regions in both time points. Even though we found many radiomics
features and preprocessing combinations with a high repeatability (Intraclass
Correlation Coefficient (ICC) > 0.85), our results indicate that overall the
repeatability is highly sensitive to the processing parameters (under certain
configurations, it can be below 0.0). Image normalization, using a variety of
approaches considered, did not result in consistent improvements in
repeatability. There was also no consistent improvement of repeatability
through the use of pre-filtering options, or by using image registration
between timepoints to improve consistency of the region of interest
localization. Based on these results we urge caution when interpreting
radiomics features and advise paying close attention to the processing
configuration details of reported results. Furthermore, we advocate reporting
all processing details in radiomics studies and strongly recommend making the
implementation available
Volumetric CT-based segmentation of NSCLC using 3D-Slicer
Accurate volumetric assessment in non-small cell lung cancer (NSCLC) is critical for adequately informing treatments. In this study we assessed the clinical relevance of a semiautomatic computed tomography (CT)-based segmentation method using the competitive region-growing based algorithm, implemented in the free and public available 3D-Slicer software platform. We compared the 3D-Slicer segmented volumes by three independent observers, who segmented the primary tumour of 20 NSCLC patients twice, to manual slice-by-slice delineations of five physicians. Furthermore, we compared all tumour contours to the macroscopic diameter of the tumour in pathology, considered as the “gold standard”. The 3D-Slicer segmented volumes demonstrated high agreement (overlap fractions > 0.90), lower volume variability (p = 0.0003) and smaller uncertainty areas (p = 0.0002), compared to manual slice-by-slice delineations. Furthermore, 3D-Slicer segmentations showed a strong correlation to pathology (r = 0.89, 95%CI, 0.81–0.94). Our results show that semiautomatic 3D-Slicer segmentations can be used for accurate contouring and are more stable than manual delineations. Therefore, 3D-Slicer can be employed as a starting point for treatment decisions or for high-throughput data mining research, such as Radiomics, where manual delineating often represent a time-consuming bottleneck
Recommended from our members
Variability in MRI vs. ultrasound measures of prostate volume and its impact on treatment recommendations for favorable-risk prostate cancer patients: a case series
Background: Prostate volume can affect whether patients qualify for brachytherapy (desired size ≥20 mL and ≤60 mL) and/or active surveillance (desired PSA density ≤0.15 for very low risk disease). This study examines variability in prostate volume measurements depending on imaging modality used (ultrasound versus MRI) and volume calculation technique (contouring versus ellipsoid) and quantifies the impact of this variability on treatment recommendations for men with favorable-risk prostate cancer. Methods: We examined 70 patients who presented consecutively for consideration of brachytherapy for favorable-risk prostate cancer who had volume estimates by three methods: contoured axial ultrasound slices, ultrasound ellipsoid (height × width × length × 0.523) calculation, and endorectal coil MRI (erMRI) ellipsoid calculation. Results: Average gland size by the contoured ultrasound, ellipsoid ultrasound, and erMRI methods were 33.99, 37.16, and 39.62 mLs, respectively. All pairwise comparisons between methods were statistically significant (all p < 0.015). Of the 66 patients who volumetrically qualified for brachytherapy on ellipsoid ultrasound measures, 22 (33.33%) did not qualify on ellipsoid erMRI or contoured ultrasound measures. 38 patients (54.28%) had PSA density ≤0.15 ng/dl as calculated using ellipsoid ultrasound volumes, compared to 34 (48.57%) and 38 patients (54.28%) using contoured ultrasound and ellipsoid erMRI volumes, respectively. Conclusions: The ultrasound ellipsoid and erMRI ellipsoid methods appeared to overestimate ultrasound contoured volume by an average of 9.34% and 16.57% respectively. 33.33% of those who qualified for brachytherapy based on ellipsoid ultrasound volume would be disqualified based on ultrasound contoured and/or erMRI ellipsoid volume. As treatment recommendations increasingly rely on estimates of prostate size, clinicians must consider method of volume estimation
Promoting the use of the PI-QUAL score for prostate MRI quality: results from the ESOR Nicholas Gourtsoyiannis teaching fellowship
OBJECTIVES: The Prostate Imaging Quality (PI-QUAL) score is a new metric to evaluate the diagnostic quality of multiparametric magnetic resonance imaging (MRI) of the prostate. This study assesses the impact of an intervention, namely a prostate MRI quality training lecture, on the participant's ability to apply PI-QUAL. METHODS: Sixteen participants (radiologists, urologists, physicists, and computer scientists) of varying experience in reviewing diagnostic prostate MRI all assessed the image quality of ten examinations from different vendors and machines. Then, they attended a dedicated lecture followed by a hands-on workshop on MRI quality assessment using the PI-QUAL score. Five scans assessed by the participants were evaluated in the workshop using the PI-QUAL score for teaching purposes. After the course, the same participants evaluated the image quality of a new set of ten scans applying the PI-QUAL score. Results were assessed using receiver operating characteristic analysis. The reference standard was the PI-QUAL score assessed by one of the developers of PI-QUAL. RESULTS: There was a significant improvement in average area under the curve for the evaluation of image quality from baseline (0.59 [95 % confidence intervals: 0.50-0.66]) to post-teaching (0.96 [0.92-0.98]), an improvement of 0.37 [0.21-0.41] (p < 0.001). CONCLUSIONS: A teaching course (dedicated lecture + hands-on workshop) on PI-QUAL significantly improved the application of this scoring system to assess the quality of prostate MRI examinations. KEY POINTS: • A significant improvement in the application of PI-QUAL for the assessment of prostate MR image quality was observed after an educational intervention. • Appropriate training on image quality can be delivered to those involved in the acquisition and interpretation of prostate MRI. • Further investigation will be needed to understand the impact on improving the acquisition of high-quality diagnostic prostate MR examinations
Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCEâ MRI: Results from a multicenter phantom study