54 research outputs found

    The formation of ore mineral deposits on the Moon: A feasibility study

    Get PDF
    Most of the ore deposits on Earth are the direct result of formation by hydrothermal solutions. Analogous mineral concentrations do not occur on the Moon, however, because of the absence of water. Stratified ore deposits form in layered instrusives on Earth due to fractional crystallization of magma and crystal settling of high-density minerals, particularly chromium in the mineral chromite. We have evaluated the possibility of such mineral deposition on the Moon, based upon considerations of 'particle settling velocities' in lunar vs. terrestrial magmas. A first approximation of Stoke's Law would seem to indicate that the lower lunar gravity (1/6 terrestrial) would result in slower crystal settling on the Moon. However, the viscosity of the silicate melt is the most important factor affecting the settling velocity. The viscosities of typical lunar basaltic melts are 10-100 times less than their terrestrial analogs. These lower viscosities result from two factors: (1) lunar basaltic melts are typically higher in FeO and lower in Al2O3, Na2O, and K2O than terrestrial melts; and (2) lunar igneous melts and phase equilibria tend to be 100-150 C higher than terrestrial, largely because of the general paucity of water and other volatile phases on the Moon. Therefore, particle settling velocities on the Moon are 5-10 times greater than those on Earth. It is highly probable that stratiform ore deposits similar to those on Earth exist on the Moon. The most likely ore minerals involved are chromite, ilmenite, and native FeNi metal. In addition, the greater settling velocities of periodotite in lunar magmas indicate that the buoyancy effects of the melt are less than on Earth. Consequently, the possibility is considerably less than on Earth of deep-seated volcanism transporting upper mantle/lower crustal xenoliths to the surface of the Moon, such as occurs in kimberlites on Earth

    Atrial natriuretic peptide and three-dimensional echocardiography after transcatheter closure of atrial septal defect

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Atrial septal defect (ASD) accounts for 10% of all congenital heart lesions and represent the third most congenital cardiac defect seen in adults. Atrial natriuretic peptide (ANP) is an important regulator of the sodium and volume homeostasis. This study was designed to investigate the changes in plasma ANP concentrations and three-dimensional echocardiography (3DE) measurements of cardiac volume in patients with ASD during transcatheter closure of defect.</p> <p>Methods</p> <p>Plasma ANP concentrations and transthoracic 3DE measurements of right ventricular volume were performed in 46 patients with ASD before closure, and at 3 days after closure. 22 healthy subjects matched for age, sex served as control subjects.</p> <p>Results</p> <p>The 46 patients (20 men, 26 women; mean age 26.32 ± 13.28, range 6 to 63 years) were diagnosed to secundum ASD (the stretched diameters of ASD were from 9~36(25.34 ± 7.80 mm), and had been successfully placed Amplatzer septal occluder (the sizes of occluder were from 11 to 40 mm). The results showed that compared with control subjects, plasma ANP concentrations were elevated in patients with ASD. Plasma ANP concentrations positively correlated significantly with pulmonary artery pressure (PAP) (r = 0.74, <it>p </it>< 0.05) and 3DE measurements of cardiac volumes (right ventricular end-diastolic (r = 0.50, <it>p </it>< 0.05) and end-systolic volume (r = 0.50, <it>p </it>< 0.05) and negatively correlated with RVEF (r = -0.38, <it>p </it>< 0.05). Transthoracic 3DE measurements of right ventricular volume and plasma ANP concentrations decreased significantly at 3 days after closure (<it>p </it>< 0.05) compared with it before closure.</p> <p>Conclusion</p> <p>Plasma ANP concentrations were markedly elevated in patients with pulmonary arterial hypertension and right ventricular volume overload and decreased significantly after closure of ASD. This study suggested that ANP may help to identify patients with ASD complicated by pulmonary arterial hypertension and right ventricular volume overload that demanded early intervention and may become effective marker for evaluating changes in cardiac load after transcatheter ASD closure.</p

    Inferring the diagnostic potential of 18F-FDG-PET/CT in post-renal transplantation from a unique case harboring multiple rare complications

    Get PDF
    Renal transplantation is undoubtedly an effective treatment for patients with end-stage renal disease, but it is certainly not a cure. Patients require lifelong immunosuppression to maintain optimal allograft function, and post-operative risk complications such as cancer in the transplant recipient cannot be ignored. Besides, infection is a silent complication that follows transplantation. Relatedly, herein, we present a report of a 40-year-old patient who underwent renal transplantation and promptly developed a diffuse large B-cell tumor in the liver and Aspergillus infection in the trachea. In addition, an inflammatory necrotizing granuloma was also observed in the muscles. Of importance, we also described the potential of 18F-FDG-PET/CT, which was instrumental in monitoring and evaluating these relevant post-operative complications in this rare case

    Ultra-high pressure balloon angioplasty for pulmonary artery stenosis in children with congenital heart defects: Short- to mid-term follow-up results from a retrospective cohort in a single tertiary center

    Get PDF
    ObjectiveBalloon angioplasty (BA) has been the treatment of choice for pulmonary artery stenosis (PAS) in children. There remains, however, a significant proportion of resistant lesions. The ultra-high pressure (UHP) balloons might be effective in a subset of these lesions. In this study, we analyzed the safety and efficacy with short- to mid-term follow-up results of UHP BA for PAS in children with congenital heart defects (CHD) in our center.MethodsThis is a retrospective cohort study in a single tertiary heart center. Children diagnosed with PAS associated with CHD were referred for UHP BA. All data with these children were collected for analysis with updated follow-up.ResultsA total of 37 UHP BAs were performed consecutively in 28 children. The success rate was 78.4%. A significantly (P = 0.005) larger ratio of the balloon to the minimal luminal diameter at the stenotic waist (balloon/waist ratio) was present in the success group (median 3.00, 1.64–8.33) compared to that in the failure group (median 1.94, 1.41 ± 4.00). Stepwise logistic regression analysis further identified that the balloon/waist ratio and the presence of therapeutic tears were two independent predictors of procedural success. The receiver operating characteristic curve revealed a cut-off value of 2.57 for the balloon/waist ratio to best differentiate success from failure cases. Signs of therapeutic tears were present in eight cases, all of whom were in the success group. Perioperative acute adverse events were recorded in 16 patients, including 11 pulmonary artery injuries, three pulmonary hemorrhages, and two pulmonary artery aneurysms. During a median follow-up period of 10.4 (0.1–21.0) months, nine cases experienced restenosis at a median time of 40 (4–325) days after angioplasty.ConclusionsThe UHP BA is safe and effective for the primary treatment of PAS in infants and children with CHD. The success rate is high with a low incidence of severe complications. The predictors of success are a larger balloon/waist ratio and the presence of therapeutic tears. The occurrence of restenosis during follow-up, however, remains a problem. A larger number of cases and longer periods of follow-up are needed for further study

    A Novel Metamaterial Inspired High-Temperature Microwave Sensor in Harsh Environments

    No full text
    A high-temperature sensor based on a metamaterial unit cell is proposed in this paper. The wireless passive temperature sensing method is based on the electromagnetic backscatter principle, and thus has the advantages of higher quality, lower environmental interference, and anti-low frequency interference. We developed a finite-element method-based model for the sensor via high-frequency simulation software (HFSS). A double split-ring resonator (SRR) with an outer ring length of 13 mm was designed on alumina ceramic substrate. The sensor was fabricated at 2.42 GHz using micromechanical technology and screen printing technology. When the temperature increased from 28 to 1100 &deg;C, the resonant frequency decreased from 2.417 to 2.320 GHz with an average sensitivity of 95.63 kHz/&deg;C. As the sensor is easily designed and fabricated, it can be used for chipless radio frequency identification (RFID) tags by simply changing the size of rings. Furthermore, emerging 3D printing technology and commercial desktop inkjet printers will be used to realize the rapid low-cost preparation of the sensor, enabling its wide range of applications in aerospace, military, manufacturing, transportation, and other fields

    STUDY ON WEAR CHARACTERISTIC OF MAIN COMPONENTS OF CONSTANT VELOCITY DRIVE SHAFT

    No full text
    Using different constant velocity drive shaft of Santana automobile with different service lives, the wear characteristics were investigated,including the external and internal splines as well as the inner and outer race of constant velocity joint. The results showed that the wear of external and internal splines for intermediate shaft was still satisfied the design standard if the service lives was less than ten years. The wear of external and internal splines for intermediate shaft exceeded the product design requirements when the Santana automobile was naturally scrapped. The wear of inner and outer race of constant velocity joint was still satisfied the design standard whenever the service lives were reached the scrapped requirement,The technical reference estimated strength and life of remanufactured constant velocity drive shaft will be provided by our experiments data and results

    E-Health Self-Help Diagnosis from Feces Images in Real Scenes

    No full text
    Deep learning models and computer vision are commonly integrated for e-health self-help diagnosis. The abnormal colors and traits of feces can reveal the risks of cancer and digestive diseases. As such, this paper develops a self-help diagnostic system to conveniently analyze users’ health conditions from feces images at home, which can reduce dependence on professional skills and examinations equipment. Unfortunately, real scenes at home suffer from several severe challenges, including the lack of labeled data, complex backgrounds, varying illumination, etc. A semi-supervised learning strategy is employed to solve the scarcity of labeled data and reduce the burden of manual labeling. The unlabeled data are classified by an initial model that is pretrained on a small number of training data. Then, the labels with high confidence are allocated to the unlabeled samples in order to extend the training data accordingly. With regard to the small feces areas in certain samples, an adaptive upsampling method is proposed to enlarge the suitable local area according to the proportion of the foreground. Synthesized feces images in real scenes are tested to confirm the effectiveness and efficiency of the proposed method. In terms of accuracy, our proposed model can achieve 100% and 99.2% on color and trait recognition in medical scenes, respectively, and 99.1% and 100% on color and trait recognition in real scenes, respectively. The related datasets and codes will be released on Github
    • …
    corecore