26 research outputs found

    The Evolution of the International Refugee Protection Regime

    Get PDF
    A short historical perspective on the United Nations High Commissioner for Refugees (UNHCR) is followed by a review of how the international refugee protection regime has evolved over the past half century

    HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations

    Get PDF
    The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices

    Mediterranean migration: a comprehensive response

    No full text
    Ensuring an effective, coherent and humane response tomixed migratory movements remains a major challenge

    Refugee Protection in International Law

    No full text
    lix, 717 hal.; ill.; 22 c

    Comparison of intraplatelet reactive oxygen species, mitochondrial damage, and platelet apoptosis after implantation of three continuous flow left ventricular assist devices: HeartMate II, Jarvik 2000, and HeartWare

    No full text
    Differences in device design may have an effect on platelet damage and associated clinical complications. We aimed to compare device-specific platelet functionality in 26 heart failure patients supported with three continuous-flow left ventricular assist devices: HeartMate II (n = 8), Jarvik 2000 (n = 9), and HeartWare (n = 9). Intraplatelet reactive oxygen species (ROS) generation, mitochondrial damage, and platelet apoptosis were compared between device types before and after the implantation at every week up to 1 month. Overall, the baseline characteristics, demographics, routine laboratory values were comparable between the three device groups. Intraplatelet ROS, mitochondrial damage, and platelet apoptosis significantly elevated in the HeartWare group in comparison with the other two device groups after implantation. The major bleeding, infections, systemic inflammatory response syndrome, and right ventricular failure were found to be more common among the HeartWare group than others. Intraplatelet ROS and platelet damage levels were returned to baseline in both the HeartMate II and the Jarvik groups, whereas in HeartWare group they remained elevated. The patients with the Jarvik and the HeartMate II experienced less clinical complications and the platelet functionality is not compromised by these devices. Data from this study suggests that the continuous-flow left ventricular assist devices design may exert different effects on platelet function

    Time in therapeutic range significantly impacts survival and adverse events in destination therapy patients

    No full text
    The study aim was to examine the impact time in therapeutic range (TTR, International Normalized Ratio [INR] 2.0-3.0) has on survival and adverse events in patients receiving the HeartWare HVAD System in the ENDURANCE and ENDURANCE Supplemental Trials. Evaluable subjects (n = 495) had \u3e1 INR value recorded 1-24 months postimplant and were categorized as: low TTR (10-39%), moderate TTR (40-69%), and high TTR (≥70%). Baseline characteristics, adverse events, and survival were analyzed. Low TTR patients experienced higher rates of major bleeding (1.69 vs. 0.54 events per patient year [EPPY]; p \u3c 0.001), GI bleeding (1.22 vs. 0.38 EPPY; p \u3c 0.001), stroke (0.47 vs. 0.17 EPPY; p \u3c 0.001), thrombus requiring exchange (0.05 vs. 0.01 EPPY; p = 0.02), infection (1.44 vs. 0.69 EPPY; p \u3c 0.001), and renal dysfunction (0.23 vs. 0.05 EPPY; p \u3c 0.001) compared with high TTR. Moderate TTR had higher rates of major bleeding (0.75 vs. 0.54 EPPY; p \u3c 0.001), thrombus requiring exchange (0.05 vs. 0.01 EPPY; p = 0.007), cardiac arrhythmia (0.32 vs. 0.24 EPPY; p = 0.04), and infection (0.90 vs. 0.69 EPPY; p = 0.001) compared with high TTR. Two year survival was greater among moderate and high versus low cohorts (Log-rank p = 0.001). The significant reduction in morbidity and mortality in destination therapy (DT) HVAD patients with well-controlled TTR (≥70%) emphasizes the importance of vigilant anticoagulation management
    corecore