24 research outputs found

    Insolubility Theorems and EPR Argument

    Get PDF
    I wish to thank in particular Arthur Fine for very perceptive comments on a previous draft of this paper. Many thanks also to Theo Nieuwenhuizen for inspiration, to Max Schlosshauer for correspondence, to two anonymous referees for shrewd observations, and to audiences at Aberdeen, Cagliari and Oxford (in particular to Harvey Brown, Elise Crull, Simon Saunders, Chris Timpson and David Wallace) for stimulating questions. This paper was written during my tenure of a Leverhulme Grant on ‘The Einstein Paradox’: The Debate on Nonlocality and Incompleteness in 1935 (Project Grant nr. F/00 152/AN), and it was revised for publication during my tenure of a Visiting Professorship in the Doctoral School of Philosophy and Epistemology, University of Cagliari (Contract nr. 268/21647).Peer reviewedPostprin

    Geographic and Sociodemographic Disparities in Drive Times to Joint Commission–Certified Primary Stroke Centers in North Carolina, South Carolina, and Georgia

    Get PDF
    Introduction: Timely access to facilities that provide acute stroke care is necessary to reduce disabilities and death from stroke. We examined geographic and sociodemographic disparities in drive times to Joint Commission–certified primary stroke centers (JCPSCs) and other hospitals with stroke care quality improvement initiatives in North Carolina, South Carolina, and Georgia. Methods: We defined boundaries for 30- and 60-minute drive-time areas to JCPSCs and other hospitals by using geographic information systems (GIS) mapping technology and calculated the proportions of the population living in these drive-time areas by sociodemographic characteristics. Age-adjusted county-level stroke death rates were overlaid onto the drive-time areas. Results: Approximately 55% of the population lived within a 30-minute drive time to a JCPSC; 77% lived within a 60-minute drive time. Disparities in percentage of the population within 30-minute drive times were found by race/ethnicity, education, income, and urban/rural status; the disparity was largest between urban areas (70% lived within 30-minute drive time) and rural areas (26%). The rural coastal plains had the largest concentration of counties with high stroke death rates and the fewest JCPSCs. Conclusion: Many areas in this tri-state region lack timely access to JCPSCs. Alternative strategies are needed to expand provision of quality acute stroke care in this region. GIS modeling is valuable for examining and strategically planning the distribution of hospitals providing acute stroke care

    Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating

    Get PDF
    Background: Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies. However, dynamic fetal CMR is difficult due to the lack of direct in-utero cardiac gating. The aim of this study was to investigate the effectiveness of a newly developed Doppler ultrasound (DUS) device in humans for fetal CMR gating. Methods: Fifteen fetuses (gestational age 30–39 weeks) were examined using 1.5 T CMR scanners at three different imaging sites. A newly developed CMR-compatible DUS device was used to generate gating signals from fetal cardiac motion. Gated dynamic balanced steady-state free precession images were acquired in 4-chamber and short-axis cardiac views. Gating signals during data acquisition were analyzed with respect to trigger variability and sensitivity. Image quality was assessed by measuring endocardial blurring (EB) and by image evaluation using a 4-point scale. Left ventricular (LV) volumetry was performed using the single-plane ellipsoid model. Results: Gating signals from the fetal heart were detected with a variability of 26 ± 22 ms and a sensitivity of trigger detection of 96 ± 4%. EB was 2.9 ± 0.6 pixels (4-chamber) and 2.5 ± 0.1 pixels (short axis). Image quality scores were 3.6 ± 0.6 (overall), 3.4 ± 0.7 (mitral valve), 3.4 ± 0.7 (foramen ovale), 3.6 ± 0.7 (atrial septum), 3.7 ± 0.5 (papillary muscles), 3.8 ± 0.4 (differentiation myocardium/lumen), 3.7 ± 0.5 (differentiation myocardium/lung), and 3.9 ± 0.4 (systolic myocardial thickening). Inter-observer agreement for the scores was moderate to very good (kappa 0.57–0.84) for all structures. LV volumetry revealed mean values of 2.8 ± 1.2 ml (end-diastolic volume), 0.9 ± 0.4 ml (end systolic volume), 1.9 ± 0.8 ml (stroke volume), and 69.1 ± 8.4% (ejection fraction). Conclusion: High-quality dynamic fetal CMR was successfully performed using a newly developed DUS device for direct fetal cardiac gating. This technique has the potential to improve the utility of fetal CMR in the evaluation of congenital pathologies

    Do dividends signal future earnings in the Nordic stock markets?

    Get PDF
    We study the informational content of dividends on three Nordic civil law markets, where other simultaneous but blurring motives for dividends may be weaker. Using aggregate data on real earnings per share and payout ratios, long time series from 1969 to 2010, and methodologies which address problems of endogeneity, non-stationarity and autocorrelation (including a Vector Error Correction Model approach), we find evidence on dividend signaling in Nordic markets. However, we also find heterogeneity in the relationship between dividends and earnings on markets similar in many respects, suggesting that even small variations in the institutional surroundings may be important for the results
    corecore