4,791 research outputs found
Recommended from our members
Assessment of carotid atherosclerotic disease using three-dimensional cardiovascular magnetic resonance vessel wall imaging: comparison with digital subtraction angiography.
BACKGROUND:A three-dimensional (3D) cardiovascular magnetic resonance (CMR) vessel wall imaging (VWI) technique based on 3D T1 weighted (T1w) Sampling Perfection with Application-optimized Contrast using different flip angle Evolutions (SPACE) has recently been used as a promising CMR imaging modality for evaluating extra-cranial and intra-cranial vessel walls. However, this technique is yet to be validated against the current diagnostic imaging standard. We therefore aimed to evaluate the diagnostic performance of 3D CMR VWI in characterizing carotid disease using intra-arterial digital subtraction angiography (DSA) as a reference. METHODS:Consecutive patients with at least unilateral > 50% carotid stenosis on ultrasound were scheduled to undergo interventional therapy were invited to participate. The following metrics were measured using 3D CMR VWI and DSA: lumen diameter of the common carotid artery (CCA) and segments C1-C7, stenosis diameter, reference diameter, lesion length, stenosis degree, and ulceration. We assessed the diagnostic sensitivity, specificity, accuracy, and receiver operating characteristic (ROC) curve of 3D CMR VWI, and used Cohen's kappa, the intraclass correlation coefficient (ICC), and Bland-Altman analyses to assess the diagnostic agreement between 3D CMR VWI and DSA. RESULTS:The ICC (all ICCs ≥0.96) and Bland-Altman plots indicated excellent inter-reader agreement in all individual morphologic measurements by 3D CMR VWI. Excellent agreement in all individual morphologic measurements were also found between 3D CMR VWI and DSA. In addition, 3D CMR VWI had high sensitivity (98.4, 97.4, 80.0, 100.0%), specificity (100.0, 94.5, 99.1, 98.0%), and Cohen's kappa (0.99, 0.89, 0.84, 0.96) for detecting stenosis > 50%, stenosis > 70%, ulceration, and total occlusion, respectively, using DSA as the standard. The AUC of 3D CMR VWI for predicting stenosis > 50 and > 70% were 0.998 and 0.999, respectively. CONCLUSIONS:The 3D CMR VWI technique enables accurate diagnosis and luminal feature assessment of carotid artery atherosclerosis, suggesting that this imaging modality may be useful for routine imaging workups and provide comprehensive information for both the vessel wall and lumen
Corporate Social Responsibility Reporting, Pyramidal Structure And Political Interference: Evidence From China
This paper attempts to investigate the relation between pyramidal structure and corporate social responsibility (CSR) reporting quality and the effect of political interference on the relation. Based on 1388 Chinese A-share listed firms during 2010-2012, this paper demonstrates that the separation between control and ownership rights is significantly and positively related to the CSR reporting quality in the state-owned firms (SOFs), while negatively related to the CSR reporting quality in the non-state-owned firms (NSOFs). Results also indicate that the pyramidal layer between the bottom firms and their top ultimate owners is negatively related to CSR reporting quality, particularly significant for the NSOFs. Our research enriches the corporate governance literature by giving insights into the mechanism of pyramidal structure in corporate reporting, and extends the understanding of political interference in the CSR field. This study has public policy implications for China as well as a number of other countries in the Asia–Pacific region.
Characterization of the residual stresses in spray-formed steels using neutron diffraction
Neutron diffraction was used to characterize the residual stresses in an as-sprayed tube-shaped steel preform. The measured residual stress distributions were compared with those simulated using finite element method by taking into account the effects of the thermal history, porosity and different phases of the sprayed preform. The porosity was measured using X-ray microcomputed tomography. The study revealed for the first time the correlation between the distribution of porosity and residual stress developed in the as-sprayed preform
A set of exactly solvable Ising models with half-odd-integer spin
We present a set of exactly solvable Ising models, with half-odd-integer
spin-S on a square-type lattice including a quartic interaction term in the
Hamiltonian. The particular properties of the mixed lattice, associated with
mixed half-odd-integer spin-(S,1/2) and only nearest-neighbour interaction,
allow us to map this system either onto a purely spin-1/2 lattice or onto a
purely spin-S lattice. By imposing the condition that the mixed
half-odd-integer spin-(S,1/2) lattice must have an exact solution, we found a
set of exact solutions that satisfy the {\it free fermion} condition of the
eight vertex model. The number of solutions for a general half-odd-integer
spin-S is given by . Therefore we conclude that this transformation is
equivalent to a simple spin transformation which is independent of the
coordination number
- …