51 research outputs found

    Firm insoles effectively reduce hemolysis in runners during long distance running - a comparative study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Shock absorbing insoles are effective in reducing the magnitude and rate of loading of peak impact forces generated at foot strike during running, whereas the foot impact force during running has been considered to be an important cause of intravascular hemolysis in long distance runners. Objective of this study was to evaluate the intravascular hemolysis during running and compare the effect of two different types of insoles (Soft and Firm) on hemolysis.</p> <p>Methods</p> <p>Twenty male long and middle distance runners volunteered to participate in this study. We selected two insoles (Soft and Firm) according to their hardness level (SHORE 'A' scale). Participants were randomly assigned to the soft insole (group 1) and firm insole (group 2) group with ten athletes in each group. Each athlete completed one hour of running at the calculated target heart rate (60-70%). Venous blood samples were collected before and immediately after running. We measured unconjucated bilirubin (mg/dl), lactate dehydrogenase (μ/ml), hemoglobin (g/l) and serum ferritin (ng/ml) as indicators of hemolysis.</p> <p>Results</p> <p>Our study revealed a significant increase in the mean values of unconjucated bilirubin (P < 0.05) while running with soft insoles indicating the occurrence of hemolysis in this group of athletes. Graphical analysis revealed an inverse relationship between hardness of insoles and hemolysis for the observed values.</p> <p>Conclusion</p> <p>Our results indicate that intravascular hemolysis occurs in athletes during long distance running and we conclude that addition of firm insoles effectively reduces the amount of hemolysis in runners compared to soft insoles.</p

    Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography

    Full text link
    To assess the prevalence and morphological characteristics of coronary artery ectasia (CAE) with CT coronary angiography (CTCA) in comparison to conventional catheterangiography (CCA). Dual-source CTCA examinations from 677 consecutive patients (223 women; median age 57 years) were retrospectively evaluated by two blinded observers for the presence of CAE defined as a diameter enlargement >/=1.5 times the diameter of adjacent normal coronary segments. Vessel diameters and contrast attenuation within and proximal to ectatic segments were measured. CCA was used to compare measurements obtained from CTCA with the coronary flow velocity by using the thrombolysis in myocardial infarction (TIMI) frame count. CTCA identified CAE in 20 of 677 (3%) patients. CCA was performed in ten of these patients. CAE diameter measurements with CTCA (10.0 +/- 5.4 mm) correlated significantly (r = 0.92, p < 0.001) with the CCA measurements (8.8 +/- 4.9 mm), but had higher diameters (levels of agreement: -1.0 to 3.4 mm). Contrast attenuation was significantly lower in the ectatic (343 +/- 63 HU) than in the proximal (394 +/- 60 HU) segments (p < 0.01). The attenuation difference significantly correlated with the CAE ratio (r = 0.67, p < 0.01) and the TIMI frame count (r = 0.58, p < 0.05). The prevalence of CAE in a population examined by CTCA is around 3%. Contrast attenuation measurements with CTCA correlate well with the flow alterations assessed with CCA

    Influence of handaxe size and shape on cutting efficiency: a large-scale experiment and morphometric analysis

    Get PDF
    Handaxes represent one of the most temporally enduring and geographically widespread of Palaeolithic artifacts and thus comprised a key technological strategy of many hominin populations. Archaeologically observable variation in the size (i.e., mass) and shape properties of handaxes has been frequently noted. It is logical to ask whether some of this variability may have had functional implications. Here, we report the results of a large-scale (n = 500 handaxes) experiment designed to examine the influence of variation in handaxe size and shape on cutting efficiency rates during a laboratory task. We used a comprehensive dataset of morphometric (size-adjusted) shape variables and statistical methods (including multivariate methods) to address this issue. Our first set of analyses focused on handaxe mass/size variability. This analysis demonstrated that, at a broad-scale level of variation, handaxe mass may have been free to vary independently of functional (cutting) efficiency. Our analysis also, however, identified that there will be a task-specific threshold in terms of functional effectiveness at the lower end of handaxe mass variation. This implies that hominins may have targeted design forms to meet minimal (task-specific) thresholds, and may also have managed handaxe reduction and discard in respect to such factors. Our second set of analyses focused on handaxe shape variability. This analysis also indicated that considerable variation in handaxe shape may occur independently of any strong effect on cutting efficiency. We discuss how these results have several implications for considerations of handaxe variation in the archaeological record. At a general level, our results demonstrate that variability within and between handaxe assemblages in terms of their size and shape properties will not necessarily have had immediate or strong impact on their effectiveness when used for cutting, and that such variability may have been related to factors other than functional issues

    Exercise capacity in patients with severe left ventricular dysfunction.

    No full text

    Electrical safety standards for electrocardiographic apparatus.

    No full text
    • …
    corecore