34 research outputs found

    Energy Analysis of a Novel Ejector-Compressor Cooling Cycle Driven by Electricity and Heat (Waste Heat or Solar Energy)

    Get PDF
    Low-grade heat is abundantly available as solar thermal energy and as industrial waste heat. Non concentrating solar collectors can provide heat with temperatures 75−100 °C. In this paper, a new system is proposed and analyzed which enhances the electrical coefficient of performance (COP) of vapour compression cycle (VCC) by incorporating low-temperature heat-driven ejectors. This novel system, ejector enhanced vapour compression refrigeration cycle (EEVCRC), significantly increases the electrical COP of the system while utilizing abundantly available low-temperature solar or waste heat (below 100 °C). This system uses two ejectors in an innovative way such that the higher-pressure ejector is used at the downstream of the electrically driven compressor to help reduce the delivery pressure for the electrical compressor. The lower pressure ejector is used to reduce the quality of wet vapour at the entrance of the evaporator. This system has been modelled in Engineering Equation Solver (EES) and its performance is theoretically compared with conventional VCC, enhanced ejector refrigeration system (EERS), and ejection-compression system (ECS). The proposed EEVCRC gives better electrical COP as compared to all the three systems. The parametric study has been conducted and it is found that the COP of the proposed system increases exponentially at lower condensation temperature and higher evaporator temperature. At 50 °C condenser temperature, the electrical COP of EEVCRC is 50% higher than conventional VCC while at 35 °C, the electrical COP of EEVCRC is 90% higher than conventional VCC. For the higher temperature heat source, and hence the higher generator temperatures, the electrical COP of EEVCRC increases linearly while there is no increase in the electrical COP for ECS. The better global COP indicates that a small solar collector will be needed if this system is driven by solar thermal energy. It is found that by using the second ejector at the upstream of the electrical compressor, the electrical COP is increased by 49.2% as compared to a single ejector system

    Machine learning-based prediction of specific energy consumption for cut-off grinding

    Get PDF
    Cut-off operation is widely used in the manufacturing industry and is highly energy-intensive. Prediction of specific energy consumption (SEC) using data-driven models is a promising means to understand, analyze and reduce energy consumption for cut-off grinding. The present article aims to put forth a novel methodology to predict and validate the specific energy consumption for cut-off grinding of oxygen-free copper (OFC–C10100) using supervised machine learning techniques. State-of-the-art experimental setup was designed to perform the abrasive cutting of the material at various cutting conditions. First, energy consumption values were predicted on the bases of input process parameters of feed rate, cutting thickness, and cutting tool type using the three supervised learning techniques of Gaussian process regression, regression trees, and artificial neural network (ANN). Among the three algorithms, Gaussian process regression performance was found to be superior, with minimum errors during validation and testing. The predicted values of energy consumption were then exploited to evaluate the specific energy consumption (SEC), which turned out to be highly accurate, with a correlation coefficient of 0.98. The relationship of the predicted specific energy consumption (SEC) with material removal rate agrees well with the relationship depicted in physical models, which further validates the accuracy of the prediction models.Peer ReviewedPostprint (published version

    Energy and Exergy Analysis of Vapor Compression Refrigeration System with Low-GWP Refrigerants

    Get PDF
    In this paper, a first- and second-law analysis of vapor compression refrigeration is presented to estimate and propose the replacement of R134 with working fluids having less global warming potential (GWP) and less exergy destruction and irreversibilities. Six different refrigerants were studied, namely, R717, R1234yf, R290, R134a, R600a, and R152a. A thermodynamic model was designed on Engineering Equation Solver (EES) software, and performance parameters were calculated. The model was deployed on all six refrigerants, while the used output parameters of performance were cooling capacity, coefficient of performance, discharge temperature, total exergy destruction, relative exergy destruction rates of different components, second-law efficiency, and efficiency defect of each component. The performance parameters were estimated at different speeds of the compressor (1000, 2000, and 3000 rpm) and fixed condenser and evaporator temperatures of 50 °C and 5 °C, respectively. The isentropic efficiency of the compressor was the same as the volumetric efficiency, and it was taken as 75%, 65%, and 55% at the compressor speeds of 1000 rpm, 2000 rpm, and 3000 rpm, respectively. A comparison of the performance parameters was presented by importing the results in MATLAB. It was found that the compressor had the highest exergy destruction compared to the other components. It was found that R152 was the refrigerant with zero ozone depletion potential (ODP) and a GWP value of 140 with less exergy destruction and irreversibilities. Moreover, it was easy to use R152a with good thermodynamic characteristics. It is estimated that R152a is a suitable replacement for R134a, as it can be used with few modifications

    Enviro-Economic Assessment of HHO–CNG Mixture Utilization in Spark Ignition Engine for Performance and Environmental Sustainability

    Get PDF
    Road transportation has received the attention of researchers due to its higher carbon footprint. Alternative fuels present major advantages in terms of environmental sustainability. For this reason, an enviro-economic analysis of alternative fuels carries great significance. However, scarce attempts have been rendered in order to ascertain the impact of a hydroxy gas (HHO) and compressed natural gas (CNG) mixture on sustainable environmental development. The current study addresses this issue by employing an HHO–CNG mixture and gasoline in spark ignition (SI) engines for the purposes of performance and environmental pollutants measurement. Then, engine emission data were substituted for Weibull distribution in order to establish suitability for 50 and 95% confidence intervals (CIs). The mixture outperformed gasoline in terms of brake-specific fuel consumption (BSFC) and emission contents. On average, hydroxy gas with CNG produced 10.59% lower oxides of nitrogen (NOX) comparative to gasoline. Finally, the enviro-economic analysis also turned out to be in favor of the hydroxy gas mixture owing to a saving of 36.14% in USD/year due to 27.87% lower production of carbon dioxide (CO2) emission

    Modelling Framework for Reducing Energy Loads to Achieve Net-Zero Energy Building in Semi-Arid Climate: A Case Study

    Get PDF
    Buildings consume a significant 40% of global energy, where, reducing the building energy consumption to a minimum, virtually zero, has become a thriving research area. Accordingly, this research aimed to determine and portray the huge potential of energy conservation in existing structures by making a retrofit at relatively low costs in finance strained economies. A walk-through of the survey of energy consuming appliances determined the energy consumption based on the power rating; the appliances were then virtually replaced and the reduced energy consumption was determined in terms of the cooling loads. Modelling these intervention using the hourly analysis program (HAP) showed significantly positive results. The pre- and post-retrofit model analysis of an institutional building in Pakistan exhibited significant potential for reducing the cooling load of 767 kW (218 TON) to 408 kW (116 TON) with an investment payback period of 2.5 years. The additional benefit is the reduced greenhouse gas (GHG) emissions which reduce the overall energy requirements. The study continues with the design of a solar energy source using the system advisor model (SAM) for the reduced energy demand of a retrofitted building. It is then concluded that using the available area, a solar energy source with a capital payback period of 5.7 years would bring an institutional building within its own energy footprint making it a net-zero building, since it will not be consuming energy from any other source outside of its own covered area. The study has the limitation to exposure and climate related conditions. In addition, the decline in heating and cooling loads represents model values which may vary when calculated after an actual retrofit for the same structure due to any site related issues

    Carbon Dioxide Utilization? A Critical Review from Multiscale Perspective

    Get PDF
    Carbon dioxide (CO2) emissions contribute considerably towards increasing greenhouse effect. Carbon capture and storage can reduce CO2 emissions to a great extent but lacks economic feasibility. The economic feasibility of CO2 capture could be boosted by utilizing the captured gas to produce valuable end products. CO2 is a highly stable molecule; therefore, special catalysts and elevated conditions of temperature and pressure are required for its conversion. This review presents the current status of CO2 utilization processes from various aspects, including thermodynamic, economic, and environmental impacts. The use of process systems engineering (PSE) tools and techniques in a broad spectrum, to improve the technical, economic, and environmental feasibility of these processes, is the major focus of this review. In this regard, a framework has also been presented showing the integration of various PSE techniques. All the related information in the form of tabulated data as well as qualitative and quantitative plots have been presented and critically analyzed

    Performance Evaluation of Phenol-Resin-Based Adsorbents for Heat Transformation Applications

    Get PDF
    Phenol resins (PRs) are considered as relatively inexpensive adsorbents synthesized from agricultural biomass via employing a variety of synthesized procedures. The performance of PR for heat transformation application is not widely investigated. In this regard, the present study aims to evaluate the four PR derivative/refrigerant pairs, namely (i) KOH6-PR/CO2, (ii) SAC-2/HFC, (iii) KOH4-PR/ethanol, and (iv) KOH6-PR/ethanol, for adsorption cooling and adsorption heating applications. Ideal cycle analyses and/or thermodynamic modelling approaches were utilized comprising governing heat and mass balance equations and adsorption equilibrium models. The performance of the AHP system is explored by means of specific cooling energy (SCE), specific heating energy (SHE), and coefficient of performance (COP), both for cooling and heating applications, respectively. It has been realized that KOH6-PR/ethanol could produce a maximum SCE of 1080 kJ/kg/cycle and SHE of 2141 kJ/kg/cycle at a regeneration temperature (Treg) and condenser temperature (Tcond) of 80 °C, and 10 °C, respectively, followed by KOH4-PR/ethanol, SAC-2/HFC-32, and KOH6-PR/CO2. The maximum COP values were estimated to be 1.78 for heating and 0.80 for cooling applications, respectively, at Treg = 80 °C and Tcond = 10 °C. In addition, the study reveals that, corresponding to increase/decrease in condenser/evaporator pressure, both SCE and SHE decrease/increase, respectively; however, this varies in magnitude due to adsorption equilibrium of the studied PR derivative/refrigerant pairs

    Exploring copyrolysis characteristics and thermokinetics of peach stone and bituminous coal blends

    Get PDF
    Copyrolysis, being an active area of research due to its synergistic impact in utilizing diverse fuel resources, including waste materials, like, peach stone (PS), has been the focal point for this study. PS, produced in vast quantities annually and typically intended for landscaping or insulation purposes, is being studied in combination with low‐grade bituminous coal for energy utilization focusing on thermokinetics and synergistic aspects. Coal‐peach stone (C‐PS) blends were formulated at different ratios and subjected to comprehensive characterization techniques, including ultimate analysis (CHN‐S), gross calorific value (GCV), Fourier transform infrared spectroscopy, and thermogravimetric analyzer (TGA). The ultimate analysis revealed an enhancement in carbon and hydrogen content from 45.38% to 68.08% and from 3.89% to 6.96%, respectively. Additionally, a reduction in sulfur and nitrogen content from 0.54% to 0.11% and from 1.16% to 0.42%, respectively, was observed with an increase in the ratio of PS in the C‐PS blends. The GCV of C‐PS blends ranged from 20.75 to 26.01 MJ kg−1. The pyrolysis conditions simulated in TGA are pivotal for evaluating thermokinetics and synergistic effects. The 60C:40PS blend shows a positive synergy index (SI) value of 0.0203% concerning total mass loss (MLT) indicating a favorable condition for bio‐oil generation. Coats–Redfern model‐fitting method reveals that the activation energy (Ea) of C‐PS blends increases in Section II with the addition of PS, and conversely, it decreases in Section III. The Ea for 100PS and 100C was 106.76 and 45.85 kJ mol−1 through (D3) and (F1), respectively, which was improved through the optimal blend 60C:40PS with an Ea of 94.56 and 27.58 kJ mol−1 through (D3) and (F2), respectively. The values obtained from linear regression prove that the kinetic models are effective while the thermodynamic analysis indicates that the pyrolytic behavior of C‐PS blends is characterized as endothermic, nonspontaneous, and capable of achieving thermodynamic equilibrium more rapidly

    Direct Analytical Modeling for Optimal, On-Design Performance of Ejector for Simulating Heat-Driven Systems

    Get PDF
    This paper describes an ejector model for the prediction of on-design performance under available conditions. This is a direct method of calculating the optimal ejector performance (entrainment ratio or ER) without the need for iterative methods, which have been conventionally used. The values of three ejector efficiencies used to account for losses in the ejector are calculated by using a systematic approach (by employing CFD analysis) rather than the hit and trial method. Both experimental and analytical data from literature are used to validate the presented analytical model with good agreement for on-design performance. R245fa working fluid has been used for low-grade heat applications, and Engineering Equation Solver (EES) has been employed for simulating the proposed model. The presented model is suitable for integration with any thermal system model and its optimization because of its direct, non-iterative methodology. This model is a non-dimensional model and therefore requires no geometrical dimensions to be able to calculate ejector performance. The model has been validated against various experimental results, and the model is employed to generate the ejector performance curves for R245fa working fluid. In addition, system simulation results of the ejector refrigeration system (ERS) and combined cooling and power (CCP) system have been produced by using the proposed analytical model
    corecore