48 research outputs found

    Robustness and Reproducibility of a Glenoid-Centered Scapular Coordinate System Derived From Low-Dose Stereoradiography Analysis

    Get PDF
    A robust and reproducible scapular coordinate system is necessary to study scapulo-thoracic kinematics. The coordinate system recommended by the ISB (International Society of Biomechanics) is difficult to apply in studies using medical imaging, which mostly use a glenoid-centered coordinate system. The aim of this study was to assess the robustness of a glenoid-centered coordinate system compared to the ISB coordinate system, and to study the reproducibility of this coordinate system measure during abduction. A Monte-Carlo analysis was performed to test the robustness of the two coordinate systems. This method enabled the variability of the orientation of the coordinate system to be assessed in laboratory setting. A reproducibility study of the glenoid-centered coordinate system in the thorax reference frame was performed during abduction in the scapular plane using a low-dose stereoradiography system. We showed that the glenoid-centered coordinate system was slightly more robust than the ISB-recommended coordinate system. Most reproducible rotation was upward/downward rotation (x axis) and most reproducible translation was along the Y axis (superior-inferior translation). In conclusion, the glenoid-centered coordinate system can be used with confidence for scapular kinematics analysis. The uncertainty of the measures derived from our technique is acceptable compared to that reported in the literature. Functional quantitative analysis of the scapular-thoracic joint is possible with this method.We would like to thank Guillaume Simer and Benjamin Aubert for their technical support. Funding: IRSST, ParisTech BiomecAM Chair, Société Générale and Covea

    Three-Dimensional Rotations of the Scapula During Arm Abduction: Evaluation of the Acromion Marker Cluster Method in Comparison With a Model-Based Approach Using Biplanar Radiograph Images

    Get PDF
    Noninvasive methods enabling measurement of shoulder bone positions are paramount in clinical and ergonomics applications. In this study, the acromion marker cluster (AMC) method is assessed in comparison with a model-based approach allowing scapula tracking from low-dose biplanar radiograph images. Six healthy male subjects participated in this study. Data acquisition was performed for 6 arm abduction positions (0°, 45°, 90°, 120°, 150°, 180°). Scapula rotations were calculated using the coordinate systems and angle sequence was defined by the ISB. The comparison analysis was based on root mean square error (RMSE) calculation and nonparametric statistical tests. RMSE remained under 8° for 0° to 90° arm abduction and under 13.5° for 0° to 180° abduction; no significant differences were found between the 2 methods. Compared with previous works, an improved accuracy of the AMC approach at high arm abduction positions was obtained. This could be explained by the different sources of data used as the "gold standard.

    3D scapular orientation on healthy and pathologic subjects using stereoradiographs during arm elevation.

    Get PDF
    Background Alterations of the scapular kinematics in different pathologic conditions have been widely studied. However, results have shown considerable discrepancies concerning the direction and the amplitude of scapular movement. The lack of consistency in the literature probably has several explanations. The purpose of this study was to analyze scapular orientation with the arm at rest and with 90° lateral elevation in healthy and pathologic subjects by use of stereoradiographs. Materials and methods All participants (n = 65) underwent a clinical examination and magnetic resonance imaging of the shoulder to assess rotator cuff status. Participants were separated into 3 groups: healthy, rotator cuff tear (RCT), and RCT and subacromial impingement syndrome (RCT+ SIS). A 3-dimensional model of the scapula was fitted to each low-dose stereoradiograph acquired with the arm at rest and 90° arm elevation. Results Orientation of the scapula with the arm at rest was not significantly different between groups. During lateral elevation, scapular orientation was not significantly different between the healthy group and the RCT group. However, upward rotation was significantly reduced in the RCT + SIS group. Conclusion Alterations of scapular kinematics in symptomatic subjects are multifactorial. We observed a link between clinically assessed subacromial impingement and scapular orientation during lateral elevation of the arm.Funding: IRSST, ParisTech BiomecAM Chair, Société Générale, and Covea

    Investigation of 3D glenohumeral displacements from 3D reconstruction using biplane X-ray images: Accuracy and reproducibility of the technique and preliminary analysis in rotator cuff tear patients

    Get PDF
    Rotator cuff (RC) tears may be associated with increased glenohumeral instability; however, this instability is difficult to quantify using currently available diagnostic tools. Recently, the three-dimensional (3D) reconstruction and registration method of the scapula and humeral head, based on sequences of low-dose biplane X-ray images, has been proposed for glenohumeral displacement assessment. This research aimed to evaluate the accuracy and reproducibility of this technique and to investigate its potential with a preliminary application comparing RC tear patients and asymptomatic volunteers. Accuracy was assessed using CT scan model registration on biplane X-ray images for five cadaveric shoulder specimens and showed differences ranging from 0.6 to 1.4 mm depending on the direction of interest. Intra- and interobserver reproducibility was assessed through two operators who repeated the reconstruction of five subjects three times, allowing defining 95% confidence interval ranging from ±1.8 to ±3.6 mm. Intraclass correlation coefficient varied between 0.84 and 0.98. Comparison between RC tear patients and asymptomatic volunteers showed differences of glenohumeral displacements, especially in the superoinferior direction when shoulder was abducted at 20 and 45 . This study thus assessed the accuracy of the low-dose 3D biplane X-ray reconstruction technique for glenohumeral displacement assessment and showed potential in biomechanical and clinical research.Fondation Paris-Tech Programme BIOMECAM Chaire ParisTech Institut de Recherche Robert-Sauvé en Santé et Sécurité du Travail du Québec Natural Science and Engineering Research Council of Canada Fonds de Recherche sur la Nature et les Technologies du Québec Fonds de Recherche en Santé du Québec, EOS Imaging, and French pôle de compétitivité MEDICEN (STEREOS + program)

    Complications des ligamentoplasties du genou (à suivre dans le n° 424, le n° 425, le n° 426)

    No full text
    Confabulations comprise a puzzling collection of false statements, produced without conscious intent to deceive. They have been classified according to the mode of elicitation (spontaneous vs. provoked), the content (fantastic vs. plausible), the memory domain in which they become manifest (episodic vs. semantic), their stability (stable vs. ephemeral), or their selectivity (monothematic vs. multithematic). All classifications appear to be problematic, because there are no clear-cut dichotomies, and confabulations often seem to fall into overlapping categories. There are, in fact, many theories, presumably explaining different kinds of confabulations; the best bet is to regard them as complementary rather than competing
    corecore