133 research outputs found

    Breast Cancer Preoperative Staging: Does Contrast-Enhanced Magnetic Resonance Mammography Modify Surgery?

    Get PDF
    Women with newly diagnosed breast cancer may have lesions undetected by conventional imaging. Recently contrast-enhanced magnetic resonance mammography (CE-MRM) showed higher sensitivity in breast lesions detection. The present analysis was aimed at evaluating the benefit of preoperative CE-MRM in the surgical planning. From 2005 to 2009, 525 consecutive women (25–75 years) with breast cancer, newly diagnosed by mammography, ultrasound, and needle-biopsy, underwent CE-MRM. The median invasive tumour size was 19 mm. In 144 patients, CE-MRM identified additional lesions. After secondlook, 119 patients underwent additional biopsy. CE-MRM altered surgery in 118 patients: 57 received double lumpectomy or wider excision (41 beneficial), 41 required mastectomy (40 beneficial), and 20 underwent contra lateral surgery (18 beneficial). The overall false-positive rate was 27.1% (39/144). CE-MRM contributed significantly to the management of breast cancer, suggesting more extensive disease in 144/525 (27.4%) patients and changing the surgical plan in 118/525 (22.5%) patients (99/525, 18.8% beneficial)

    Post-Irradiation Hyperamylasemia Is a Prognostic Marker for Allogeneic Hematopoietic Stem Cell Transplantation Outcomes in Pediatric Population: A Retrospective Single-Centre Cohort Analysis

    Get PDF
    Background: Total body irradiation (TBI) is a mandatory step for patients with acute lymphoblastic leukemia (ALL), undergoing allogeneic hematopoietic stem cell transplantation (HSCT). In the past, amylases have been reported to be a possible sign of TBI toxicity. We investigated the relationship between total amylases (TA) and transplant-related outcomes in pediatric recipients. Methods: We retrospectively analyzed the medical records of all the patients who underwent allogeneic HSCT between January 2000 and November 2019. The inclusion criteria were the following: recipient's age between 2 and 18, diagnosis of ALL, no previous transplantation, and use of TBI-based conditioning. The serum total amylase and pancreatic amylase were evaluated before, during, and after transplantation. Cytokines and chemokines assays were retrospectively performed. Results: 78 patients fulfilled the inclusion criteria. Fifty-seven patients were treated with fractionated TBI, and 21 with a single-dose regimen. The overall survival (OS) was 62.8%. Elevated values of TA were detected in 71 patients (91%). The TA were excellent in predicting the OS (AUC = 0.773; 95% CI = 0.66-0.86; p < 0.001). TA values below 374 U/L were correlated with a higher OS. The highest mean TA values (673 U/L) were associated with a high disease-progression mortality rate. The TA showed a high predictive performance for disease progression-related death (AUC = 0.865; 95% CI = 0.77-0.93; p < 0.0001). Elevated TA values were also connected with significantly higher levels of proinflammatory cytokines, such as TNF-alpha, IL-6, and RANTES (p < 0.001). Conclusions: this study shows that TA is a valuable predictor of post-transplant OS and increased risk of leukemia relapse

    Cardiac resynchronization therapy-defibrillator improves long-term survival compared with cardiac resynchronization therapy-pacemaker in patients with a class IA indication for cardiac resynchronization therapy: Data from the Contak Italian Registry

    Get PDF
    Aims In candidates for cardiac resynchronization therapy (CRT), the choice between pacemaker (CRT-P) and defibrillator (CRT-D) implantation is still debated. We compared the long-term prognosis of patients who received CRT-D or CRT-P according to class IA recommendations of the European Society of Cardiology (ESC) and who were enrolled in a multicentre prospective registry. Methods and results A total of 620 heart failure patients underwent successful implantation of a CRT device and were enrolled in the Contak Italian Registry. This analysis included 266 patients who received a CRT-D and 108 who received a CRT-P according to class IA ESC indications. Their survival status was verified after a median follow-up of 55 months. During follow-up, 73 CRT-D and 44 CRT-P patients died (rate 6.6 vs. 10.4%/year; log-rank test, P = 0.020). Patients receiving CRT-P were predominantly older, female, had no history of life-threatening ventricular arrhythmias, and more frequently presented non-ischaemic aetiology of heart failure, longer QRS durations, and worse renal function. However, the only independent predictor of death from any cause was the use of CRT-P (hazard ratio, 1.97; 95% confidence interval, 1.21–3.16; P = 0.007). Conclusion The implantation of CRT-D, rather than CRT-P, may be preferable in patients presenting with current class IA ESC indications for CRT. Indeed, CRT-D resulted in greater long-term survival and was independently associated with a better prognosis

    Post-HSCT graft failure due to refractory human cytomegalovirus successfully treated with haploidentical donor-derived immunoglobulins and stem cell graft infusion: a case report

    Get PDF
    Background: Human cytomegalovirus (HCMV) remains an important cause of transplant-related morbidity and mortality. The incidence of HCMV recurrence in the donor seronegative (D-)/recipient seropositive (R+) group is significantly higher than in other serostatus combinations as a result of a lack of pre-existing HCMV-specific memory T-lymphocytes in the donor, coupled with the eradication of the recipient's cellular immunity due to the conditioning regimen. Case presentation: We describe the case of an 8-year-old βE-thalassemic girl from Bangladesh who was seropositive for human cytomegalovirus (HCMV) and underwent hematopoietic stem cell transplantation from a HLA-matched, unrelated, HCMV-seronegative donor. Despite administering antiviral prophylaxis with commercial pooled anti-HCMV immunoglobulin (Ig) from day +1, the post-transplant course was complicated by prompt viral reactivation, and foscarnet therapy was initiated. The virus was refractory to treatment, leading rapidly to complete bone marrow failure, and targeted immunotherapy was proposed as a second-line therapy. Hypothesizing that the patient and her relatives may have been exposed to similar HCMV strains, we selected the patient's mother, who presented a high HCMV antibody titer, as the donor of virus strain-specific anti-HCMV Ig and T-lymphocytes. Complete viral clearance was achieved after two transfusions of the mother's plasma. Subsequently, the patient underwent a haploidentical rescue transplant, promptly reaching full hematological recovery. Conclusion: These findings suggest that treatment with virus strain-specific Ig may offer a new therapeutic option for critically ill patients

    INTERMUSCULAR TWO-INCISION TECHNIQUE FOR S-ICD IMPLANTATION

    Get PDF
    Background The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, which involves three incisions and a subcutaneous pocket, is associated with possible complications, including inappropriate interventions. The aim of this prospective multicenter study was to evaluate the efficacy and safety of an alternative intermuscular two-incision technique for S-ICD implantation. Methods The study population included 36 consecutive patients (75% male, mean age 44 ± 12 years [range 20–69]) who underwent S-ICD implantation using the intermuscular two-incision technique. This technique avoids the superior parasternal incision for the lead placement and consists of creating an intermuscular pocket between the anterior surface of the serratus anterior and the posterior surface of the latissimus dorsi muscles instead of a subcutaneous pocket. Results All patients were successfully implanted in the absence of any procedure-related complications with a successful 65-J standard polarity defibrillation threshold testing, except in one, who received a second successful shock after pocket revision. During a mean follow-up of 10 months (range 3–30), no complications requiring surgical revision were observed. At device interrogation, stable sensing without interferences was observed in all patients. Two patients (5.5%) experienced appropriate and successful shock on ventricular fibrillation and in four patients (11%), a total of seven nonsustained self-terminated ventricular tachycardias were correctly detected. No inappropriate interventions were observed. Conclusions Our experience suggests that the two-incision intermuscular technique is a safe and efficacious alternative to the current technique for S-ICD implantation that may help reducing complications including inappropriate interventions and offer a better cosmetic outcome, especially in thin individuals

    Longevity of Replaced ICD/CRT-D

    Get PDF
    Longevity of Replaced ICD/CRT-D Introduction The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life. Methods and Results Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis. Data on replaced devices were collected. A total of 953 patients were included in this analysis. In 813 (85%) patients the reason for replacement was battery depletion, while 88 (9%) devices were removed for clinical reasons and the remaining 52 because of system failure (i.e., lead or ICD generator failure or a safety advisory indication). The median service life was 5.9 years (25th–75th percentile, 4.9–6.9) for single- and dual-chamber ICD and 4.9 years (25th–75th percentile, 4.0–5.7) for CRT-D. On multivariate analysis, the factors CRT-D device, SC/DC ICD generator from Biotronik, percentage of ventricular pacing, and the occurrence of a system failure were positively associated with a replacement procedure. By contrast, the device from Boston Scientific was an independent protective factor against replacement. Considerable differences were seen in battery duration in both ICD and CRT-D. Specifically, Biotronik devices showed the shortest longevity among ICD and Boston Scientific showed the longest longevity among CRT-D (log-rank test, P < 0.001 for pairwise comparisons). Conclusion Several factors were associated with shorter service life of ICD devices: CRT-D, occurrence of system failure and percentage of ventricular pacing. Our results confirmed significant differences among manufacturers
    corecore