14 research outputs found

    Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The objective of the present study was to assess interobserver reproducibility (in terms of reliability and agreement) of active and passive measurements of knee RoM using a long arm goniometer, performed by trained physical therapists in a clinical setting in total knee arthroplasty patients, within the first four days after surgery.</p> <p>Methods</p> <p>Test-retest analysis</p> <p>Setting: University hospital departments of orthopaedics and physical therapy</p> <p>Participants: Two experienced physical therapists assessed 30 patients, three days after total knee arthroplasty.</p> <p>Main outcome measure: RoM measurement using a long-arm (50 cm) goniometer</p> <p>Agreement was calculated as the mean difference between observers ± 95% CI of this mean difference. The intraclass correlation coefficient (ICC) was calculated as a measure of reliability, based on two-way random effects analysis of variance.</p> <p>Results</p> <p>The lowest level of agreement was that for measurement of passive flexion with the patient in supine position (mean difference 1.4°; limits of agreement 16.2° to 19° for the difference between the two observers. The highest levels of agreement were found for measurement of passive flexion with the patient in sitting position and for measurement of passive extension (mean difference 2.7°; limits of agreement -6.7 to 12.1 and mean difference 2.2°; limits of agreement -6.2 to 10.6 degrees, respectively). The ability to differentiate between subjects ranged from 0.62 for measurement of passive extension to 0.89 for measurements of active flexion (ICC values).</p> <p>Conclusion</p> <p>Interobserver agreement for flexion as well as extension was only fair. When two different observers assess the same patients in the acute phase after total knee arthroplasty using a long arm goniometer, differences in RoM of less than eight degrees cannot be distinguished from measurement error. Reliability was found to be acceptable for comparison on group level, but poor for individual comparisons over time.</p

    Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review

    Get PDF
    The study is to provide a critical analysis of the research literature on clinimetric properties of instruments that can be used in daily practice to measure active cervical range of motion (ACROM) in patients with non-specific neck pain. A computerized literature search was performed in Medline, Cinahl and Embase from 1982 to January 2007. Two reviewers independently assessed the clinimetric properties of identified instruments using a criteria list. The search identified a total of 33 studies, investigating three different types of measurement instruments to determine ACROM. These instruments were: (1) different types of goniometers/inclinometers, (2) visual estimation, and (3) tape measurements. Intra- and inter-observer reliability was demonstrated for the cervical range of motion instrument (CROM), Cybex electronic digital instrument (EDI-320) and a single inclinometer. The presence of agreement was assessed for the EDI-320 and a single inclinometer. The CROM received a positive rating for construct validity. When clinical acceptability is taken into account both the CROM and the single inclinometer can be considered appropriate instruments for measuring the active range of motion in patients with non-specific neck pain in daily practice. Reliability is the aspect most frequently evaluated. Agreement, validity and responsiveness are documented less frequently

    Physical fitness in children with haemophilia and the effect of overweight

    No full text
    Although children with haemophilia are advised to participate in physical activities, their physical fitness has not been studied in a large group. In addition, children with haemophilia may be at increased risk for becoming overweight as a result of inactivity because of joint bleedings or because of overprotection. This study aimed to assess physical fitness (aerobic capacity), joint status, muscle strength, quality of life (QoL), self-reported motor competence and also prevalence of overweight and its association with physical parameters. Weight and height were measured. Skin folds were measured unilaterally at biceps, triceps, subscapular and supra-iliac sites. Aerobic capacity was determined on a cycle ergometer or with a 6-min walk test (6MWT). Muscle strength and active range of motion of elbows, knees and ankle joints were measured. Self-reported motor competence was measured with the 'Competentie BelevingsSchaal voor Kinderen'. Joint pain was scored on a Visual Analogue Scale. The Haemo-QoL Index was used to measure QoL. In 158 Dutch boys with haemophilia, with a mean age of 12.7 years (SD 2.9), normal aerobic capacity and muscle strength were found. Joint pain was reported by 16% of the participants. The prevalence of overweight (16%) was slightly increased when compared with healthy Dutch boys (13.5%). Being overweight had a negative association with the 6MWT and QoL. Dutch children with haemophilia have normal aerobic exercise capacity and muscle strength. The majority also has normal joint mobility. Prevalence of overweight is slightly increased

    Recent developments in clinimetric instruments

    No full text
    Assessment of impairment and function is essential in order to monitor joint status and evaluate therapeutic interventions in patients with haemophilia. The improvements in the treatment of haemophilia have required the development of more sensitive tools to detect the more minor dysfunctions that may now be apparent. This paper outlines some of the recent developments in this field. The Haemophilia Joint Health Score (HJHS) provides a systematic and robust measure of joint impairment. The MRI Scoring System has been designed to provide a comprehensive scoring system combining both progressive and additive scales. The Functional Independence Score for Haemophilia (FISH) has been developed to assess performance of functional activities and can be used in conjunction with the Haemophilia Activities List (HAL) which provides a self report measure of function. It is recommended that both measures are evaluated as these tools measure different constructs. Further refinement and testing of the psychometric properties of all of these tools is in progress. More widespread use of these tools will enable the sharing of data across the world so promoting best practice and ultimately enhancing patient care
    corecore