    Qualification of stainless steel for OTEC heat exchanger tubes

    No full text
    The history of the AL-6X alloy is reviewed and its credentials as a candidate for use as tubing in Ocean Thermal Energy Conversion Heat Exchangers are examined. Qualification is based on results of accelerated tests using ferric chloride for resistance to crevice corrosion and pitting, long-time crevice corrosion and pitting tests in natural sea water and anticipated resistance to attack by ammonia and mixtures of ammonia and sea water. Since the alloy has no natural resistance to fouling by marine organisms, it must be able to accomodate action to prevent fouling by chlorination or to remove it by mechanical cleaning techniques or appropriate chemical cleaning methods. The satisfactory behavior indicated by the various accelerated and long-time corrosion tests has been confirmed by excellent performance of several million feet of tubing in condensers in coastal power plants. Early evaluation tests demonstrated the need for proper heat treatment to avoid the presence of a sigma phase, which promoted severe pitting of some, but not all, specimens in tests in natural sea water. The available data qualify the AL-6X alloy as being a satisfactory alternate to titanium for tubes in OTEC heat exchangers

    Qualification of aluminum for OTEC heat exchangers

    No full text
    The basis for qualification of aluminum as a material for use as tubing in Ocean Thermal Energy Conversion heat exchangers is reviewed. Reference is made to compendia of data from tests of aluminum alloys in natural sea water and to applicable service records. Data from these sources were found to be inadequate to either qualify or disqualify aluminum. They serve only to identify the 5052 alloy and Alclad 3003 or 3004 as being worthy of additional testing under conditions more directly related to what will be encountered in OTEC heat exchangers. The principal deficiency of data from long-time tests in natural sea water is that in almost all of these tests the specimens were exposed under static conditions that caused the surfaces to be covered by marine fouling organisms that would not be present in heat exchanger tubes. The tests did not take into account possible effects of periodic mechanical or chemical treatments to remove fouling or chemical treatments (chlorination) to prevent fouling. A current testing program sponsored by the Department of Energy through Argonne National Laboratory is designed to provide the needed data. Limited tests in high velocity sea water have indicated that aluminum tubes would tolerate the velocities under 10 ft (3 m) per second likely to be used in OTEC heat exchangers
    corecore