451 research outputs found
Ar:N - a non-universal glass
The bias energies of various two-level systems (TLSs) and their strengths of
interactions with the strain are calculated for Ar:N glass. Unlike the case
in KBr:CN, a distinct class of TLSs having weak interaction with the strain and
untypically small bias energies is not found. The addition of CO molecules
introduces CO flips which form such a class of weakly interacting TLSs, albeit
at much lower coupling than are typically observed in solids. We conclude that
because of the absence of a distinct class of weakly interacting TLSs, Ar:N
is a non-universal glass, the first such system in three dimensions and in
ambient pressure. Our results further suggest that Ar:N:CO may show
universal properties, but at temperatures lower than K, much
smaller than typical temperature K associated with universality,
because of the untypical softness of this system. Our results thus shed light
on two long standing questions regarding low temperature properties of glasses:
the necessary and sufficient conditions for quantitative universality of phonon
attenuation, and what dictates the energy scale of K below which
universality it typically observed.Comment: 6 pages, 2 figures, results for excitations densities of states are
added, presentation improve
Is the mid-diastolic isthmus always the best ablation target for re-entrant atrial tachycardias?
Shortening of the Short Refractory Periods in Short QT Syndrome.
BACKGROUND: Diagnosis of short QT syndrome (SQTS) remains difficult in case of borderline QT values as often found in normal populations. Whether some shortening of refractory periods (RP) may help in differentiating SQTS from normal subjects is unknown. METHODS AND RESULTS: Atrial and right ventricular RP at the apex and right ventricular outflow tract as determined during standard electrophysiological study were compared between 16 SQTS patients (QTc 324±24 ms) and 15 controls with similar clinical characteristics (QTc 417±32 ms). Atrial RP were significantly shorter in SQTS compared with controls at 600- and 500-ms basic cycle lengths. Baseline ventricular RP were significantly shorter in SQTS patients than in controls, both at the apex and right ventricular outflow tract and for any cycle length. Differences remained significant for RP of any subsequent extrastimulus at any cycle length and any pacing site. A cut-off value of baseline RP <200 ms at the right ventricular outflow tract either at 600- or 500-ms cycle length had a sensitivity of 86% and a specificity of 100% for the diagnosis of SQTS. CONCLUSIONS: Patients with SQTS have shorter ventricular RP than controls, both at baseline during various cycle lengths and after premature extrastimuli. A cut-off value of 200 ms at the right ventricular outflow tract during 600- and 500-ms basic cycle length may help in detecting true SQTS from normal subjects with borderline QT values
Etiological diagnosis, prognostic significance and role of electrophysiological study in patients with Brugada ECG and syncope.
BACKGROUND: Syncope is considered a risk factor for life-threatening arrhythmias in Brugada patients. Distinguishing a benign syncope from one due to ventricular arrhythmias is often difficult, unless an ECG is recorded during the episode. Aim of the study was to analyze the characteristics of syncopal episodes in a large population of Brugada patients and evaluate the role of electrophysiological study (EPS) and the prognosis in the different subgroups. METHODS AND RESULTS: One hundred ninety-five Brugada patients with history of syncope were considered. Syncope were classified as neurally mediated (group 1, 61%) or unexplained (group 2, 39%) on the basis of personal and family history, clinical features, triggers, situations, associated signs, concomitant therapy. Most patients underwent EPS; they received ICD or implantable loop-recorder on the basis of the result of investigations and physician's judgment. At 62±45months of mean follow-up, group 1 showed a significantly lower incidence of arrhythmic events (2%) as compared to group 2 (9%, p<0.001). Group 2 patients with positive EPS showed the highest risk of arrhythmic events (27%). No ventricular events occurred in subjects with negative EPS. CONCLUSION: Etiological definition of syncope in Brugada patients is important, as it allows identifying two groups with different outcome. Patients with unexplained syncope and ventricular fibrillation induced at EPS have the highest risk of arrhythmic events. Patients presenting with neurally mediated syncope showed a prognosis similar to that of the asymptomatic and the role of EPS in this group is unproven
Left persistent superior vena cava and paroxysmal atrial fibrillation: the role of selective radiofrequency transcatheter ablation
Use of oral gadobenate dimeglumine to visualise the oesophagus during magnetic resonance angiography in patients with atrial fibrillation prior to catheter ablation.
BACKGROUND: Atrio-oesophageal fistula was first reported as a fatal complication of surgical endocardial and percutaneous endocardial radiofrequency ablation for atrial fibrillation, with an incidence after catheter ablation between 0.03% and 0.5%. Magnetic resonance angiography (MRA) was usually performed to obtain pre-procedural 3D images, used to merging into an electro-anatomical map, guiding step-by-step ablation strategy of AF. Our aim was to find an easy, safe and cost-effective way to enhance the oesophagus during MRA. METHODS: In 105 consecutive patients, a right-left phase encoding, free breathing, 3D T1 MRA sequence was performed in the axial plane, >24 hours before catheter ablation, using an intravenous injection of gadobenate dimeglumine contrast medium. The oesophagus was enhanced using an oral gel solution of 0.7 mL gadobenate dimeglumine contrast medium mixed with approximately 40 mg thickened water gel, which was swallowed by the patients on the scanning table, immediately before the MRA sequence acquisition. RESULTS: The visualisation of the oesophagus was obtained in 104/105 patients and images were successfully merged, as left atrium and pulmonary veins, into an electro-anatomical map, during percutaneous endocardial radiofrequency ablation. All patients tolerated the study protocol and no immediate or late complication was observed with the oral contrast agent administration. The free-breathing MRA sequence used in our protocol took 7 seconds longer than MRA breath-hold conventional sequence. CONCLUSION: Oesophagus visualization with oral gadobenate dimeglumine is feasible for integration of oesophagus anatomy images into the electro-anatomical map during AF ablation, without undesirable side effects and without significantly increasing cost or examination time
- …